background image

Page

MODEL   QTR100L  

5.  Connect electrical wiring.

 

Run 120 VAC house wiring to installation location. Use 

proper UL approved connector to secure house wiring to 

wiring plate. Connect wires as shown in wiring diagrams.

CONNECT WIRING

3.  Attach 

damper/duct 
connector.

 

Snap damper / 

duct connector 

onto housing. 

Make sure con-

nector is flush with 

top of housing and 

damper flap falls 

closed.

4.  Install 

4-inch 
round duct-
work.

 

Connect 4-inch 

round ductwork 

to damper / duct 

connector. Run 

ductwork to a 

roof cap or wall 

cap. Tape all 

ductwork connections to make them secure and air tight.

INSTALL HOUSING & DUCT

1.  Bend 

housing 
tabs.

 

Use a pliers to 

bend housing 

TABS

 out to 90

0

.

2.  Mount 

housing to 
joist.

 

Hold housing 

in place so that 

the housing 

tabs contact the 

bottom of the 

joist. The hous

-

ing mounts with 

four (4) screws 

or nails. Screw or 

nail housing to joist through lowest holes in each mount

-

ing flange,  then through highest holes. NOTE: Mounting 

to 

I-JOIST (shown) requires use of SPACERS (included) 

between the highest hole of each mounting flange and the 

I-joist.

SPACER

(use for mounting to I-Joist)

I-JOIST

TABS

INSTALL GRILLE

6.  Finish ceiling.

 

Install ceiling material. Cut out around housing.

7.  Attach grille 

to housing.

 

Squeeze grille 

springs and insert 

them into slots 

on each side of 

housing.

Содержание QTR100L

Страница 1: ...e dusting brush attachment The motor is permanently lubricated and never needs oiling If the motor bearings are making excessive or unusual noises replace the motor with the exact service motor The im...

Страница 2: ...chase separately The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed Use a roof cap or wall cap that has a...

Страница 3: ...to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs contact...

Страница 4: ...11293 Spacer 2 supplied 16 99420665 Thumbscrew 8 18 x 375 SERVICE NOTE To remove Blower Assembly Unplug motor 7 Remove thumbscrew 16 from motor plate 9 flange Find the single tab on the motor plate lo...

Страница 5: ...l con el due o de la casa Para lograr un funcionamiento silencioso y eficiente como tambi n larga vida y una apariencia atractiva baje o retire la rejilla y aspire el interior de la unidad con el acce...

Страница 6: ...A DE PARED Se compran por separado El ventilador funcionar con m s eficiencia y menos ruido si se ubica en un sitio donde requiera el tramo de conducto m s corto posible y un m nimo n mero de codos In...

Страница 7: ...s de los conductos para fijarlas y hacerlas herm ticas al aire 3 Acople el conectador del regulador de tiro conducto Conecte a presi n el conectador del regu lador de tiro con ducto en la cubierta Ase...

Страница 8: ...de servicio se debe especificar el n mero de la pieza no el n mero de la clave 8 Empuje la rejilla contra el cielo raso 10 Instale las bom billas Compre una bombilla incandescente m x 100 W Compre un...

Отзывы: