Broan NUTONE QTREN Series Скачать руководство пользователя страница 1

QTRE & QTREN SERIES FAN/LIGHT/NIGHT LIGHT

READ AND SAVE THESE INSTRUCTIONS

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 
or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by  qualifi ed 

personnel in accordance with all applicable codes and standards, 
including fi re-rated construction codes and standards.

4.  Suffi cient air is needed for proper combustion and exhausting 

of gases through the fl ue (chimney) of fuel burning equipment 
to prevent backdrafting. Follow the heating equipment 
manufacturer’s guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), 
and the American Society for Heating, Refrigeration and Air 
Conditioning Engineers (ASHRAE), and the local code authorities.

5.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Acceptable for use over a tub or shower when connected to a 

GFCI (Ground Fault Circuit Interrupter) - protected branch circuit.

8.  This unit must be grounded.
9.  When applicable local regulations comprise more restrictive 

installation and/or certifi cation requirements, the aforementioned 
requirements prevail on those of this document and the installer 
agrees to conform to these at his own expenses.

10. When performing installation, servicing or cleaning this unit, 

it is recommended to wear safety glasses and gloves.

CAUTION  

!

1.  For general ventilating use only. Do not use to exhaust hazardous

or explosive materials and vapors.

2.  This product is designed for installation in ceilings up to a 

12/12 pitch (45 degree angle). Duct connector must point 
up. DO NOT MOUNT THIS PRODUCT IN A WALL.

3.  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 
unit.

4.  Please read specification label on product for further 

information and requirements.

OPERATION

WARRANTY

BROAN-NUTONE CANADA INC.

THREE-YEAR LIMITED WARRANTY

Broan-NuTone Canada warrants to the original consumer purchaser of its 
products that such products will be free from defects in materials or workmanship 
for a period of three (3) years from the date of original purchase. THERE ARE 
NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT 
LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS 
FOR A PARTICULAR PURPOSE.

During this three-year period

, Broan-NuTone Canada will, at its option, 

repair or replace, without charge, any product or part which is found to be 
defective under normal use and service.

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS 
OR TUBES, BULBS OR BATTERIES, FILTERS, DUST, ROOF CAPS, WALL CAPS 
AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover (a) 
normal maintenance and service or (b) any products or parts which have been 
subject to misuse, negligence, accident, improper maintenance or repair (other 
than by Broan-NuTone Canada or an authorized representative), faulty installation 
or installation contrary to recommended installation instructions.

The duration of an implied warranty is limited to the three-year period as 
specifi ed for the express warranty.

BROAN-NUTONE CANADA’S OBLIGATION TO REPAIR OR REPLACE, AT 
BROAN-NUTONE CANADA’S OPTION, SHALL BE THE PURCHASER’S SOLE 
AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE CANADA 
SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL 
DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR 
PERFORMANCE. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan-NuTone Canada at 
the address or telephone number stated below, (b) give the model number 
and part identifi cation and (c) describe the nature of any defect in the product 
or part. At the time of requesting warranty service, you must present evidence 
of the original purchase date.

IF YOU NEED ASSISTANCE OR SERVICE:

For the location of your nearest Broan-NuTone Canada Inc. dealer:

Dial Toll Free: 

1-888-882-7626

Please be prepared to provide:

• Product model number • Date and proof of purchase 

• The nature of the diffi culty

Broan-NuTone Canada Inc. 

1140 Tristar Drive, Mississauga, Ontario L5T 1H9

INSTALLER: Leave this manual 
 

with the homeowner. 

CLEANING & MAINTENANCE

MODELS QTRE070FLC • QTRE090FLC • QTRE110FLC  

QTREN070FLC • QTREN090FLC • QTREN110FLC  

For quiet and effi cient operation, long life, and attractive appearance 
- lower or remove grille and vacuum interior of unit with the dusting 
brush attachment.
The motor is permanently lubricated and never needs oiling. If the 
motor bearings are making excessive or unusual noises, replace 
the blower assembly (includes motor and impeller).

The fan, light, and night light can be operated separately. Use a 
3-function wall control. Do not use a dimmer switch to operate 
the light. See “Connect Wiring” for details. 

Released Sept. 2012

R

EGISTER

 

YOUR

 

PRODUCT

 

ONLINE

 

AT

:

B

ROAN

 QTRE S

ERIES

WWW

.

BROAN

.

CA

N

U

T

ONE

 QTREN S

ERIES

WWW

.

NUTONE

.

CA

30042483A

1

Содержание NUTONE QTREN Series

Страница 1: ...als or workmanship for a period of three 3 years from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE During this three year period Broan NuTone Canada will at its option repair or replace without charge any product or part which is found to be defective under norma...

Страница 2: ...ousing FAN HOUSING separately 1a Mount housing to joist or I joist Use pliers to bend housing TABS out to 90 Hold housing in place so that the housing tabs contact the bottom of the joist The housing mounts with four screws or nails Screw or nail housing to joist through lowest holes in each mounting flange then through highest holes NOTE Mounting to I JOIST shown requires use of SPACERS included b...

Страница 3: ... the framing Nail ventilator to framing or fasten with screws not provided through HOLES near NAILS To ensure a noise free mount Secure hanger bars together with SCREWS or use pliers to crimp mounting channels tightly around hanger bars SCREW 2 HOLE FOR OPTIONAL SCREW MOUNTING 4 NAIL 4 BOTTOM EDGE OF FRAMING 2 Attach damper duct connector Snap damper duct connector onto housing Make sure connector...

Страница 4: ...e single TAB on the motor plate located next to the receptacle Push up near motor plate tab while pushing out on side of housing Or insert a straight blade screwdriver into slot in housing next to tab and twist screwdriver SERVICE PARTS 3 4 1 5 6 2 11 11 12 12 TAB 8 7 10 9 4 9 Install light bulbs Fluorescent bulbs supplied Purchase a 4W incandescent night light bulb Insert bulbs into their sockets...

Страница 5: ...d un aspirateur muni de la brosse à épousseter Le moteur est lubrifié à vie Aucune lubrification n est nécessaire Si les roulements du moteur produisent des bruits excessifs ou inhabituels remplacer le bloc moteur comprend le moteur et la roue de ventilateur Le ventilateur l éclairage et la veilleuse peuvent fonctionner séparément Utiliser une commande murale à trois fonctions Ne pas utiliser un gra...

Страница 6: ...ngulées à l aide de barres de suspension BH0006F MATÉRIAU DE PLAFOND GRILLE BOÎTIER BARRES DE SUSPENSION s étirent jusqu à 24 po POUTRE TRIANGULÉE CÂBLE ÉLECTRIQUE CAPUCHON DE TOIT COUDE S ROND S DE 4 po CONDUIT ROND DE 4 po CAPUCHON MURAL Vendus séparément ISOLANT Peut être placé autour et par dessus le boîtier du ventilateur BOÎTIER DU VENTILATEUR BH0043F 1a Installation du boîtier à la solive o...

Страница 7: ...s de suspension VIS 2 TROU POUR VIS DE MONTAGE OPTIONNELLE 4 CLOU 4 REBORD INFÉRIEUR DE L ARMATURE 2 Fixation du clapet raccord de conduit Installer le clapet raccord de conduit sur le boîtier S assurer qu il est à ras avec le dessus du boîtier et que le clapet se ferme parfaitement 3 Installation d un conduit rond de 4 po Fixer un conduit rond de 4 po au clapet raccord de conduit Acheminer le con...

Страница 8: ...n Description 1 97016466 Boîtier 2 97016449 Raccord de conduit de 4 po 3 98010102 Plaque de branchement 4 99170245 Vis n 8 18 x 0 375 po 2 requises 5 97016766 Panneau de branchement harnais série QTRE 97018011 Panneau de branchement harnais série QTREN 6 10941283 Bloc moteur 70 PCM QTRE FLC 10941266 Bloc moteur 90 PCM QTRE FLC 10941257 Bloc moteur 110 PCM QTRE FLC 7 97018340 Ensemble grille inclut...

Отзывы: