Broan NuTone PM44 Скачать руководство пользователя страница 2

2

VENTILATING AND WIRING 
CUTOUTS

.  Mark  locations  on  cabinet  for  ventilating  duct  and  electrical 

wiring from the dimensions given (FIGURE ).

2.  Cut holes at the marked locations to accommodate the ventilat-

ing duct and electrical wiring. Be sure to minimize openings, 

these will have to be sealed later.

3.  Run house wiring through -/2” diameter hole in cabinet or wall. 

Be sure all wiring is in accordance with the National Electrical 

Code and local ordinances.

INSTALLATION

1.  Remove the blower/lens cover and filters for easier installation. 

See the exploded assembly illustration (FIGURE 5). Remove 

the shipping material from the inside of the ventilator.

2.  Lift the ventilator into position. Mark the screw hole locations, 

on the cabinet, at the center of the narrow end of each of the 

(4) keyhole slots.

3.  Remove the unit. Start each mounting screw into the cabinet 

at the positions marked in Step 2. (FIGURE 2)

DAMPER ASSEMBLY

ROOF / WALL CAP

3-1/4” x 10” 

DUCT

KEYHOLE SLOT 

IN VENTILATOR

MOUNTING SCREW  

#10 x 5/8 Phillips - 4 provided)

FIGURE 1

FIGURE 2

FIGURE 3

1-3/8"

3,5 cm

7-1/2"

19,1 cm

1"

2,5 cm

4"

10,2 cm

5-1/4"

13,3 cm

7-1/2"

3,5 cm

1-3/8"

2,5 cm

ELECTRICAL WIRING

LOCATION OPTIONS

1-1/2" DIAMETER

5-1/4"

13,3 cm

CABINET

CUTOUTS

4.  Attach the 3¼” x 10” damper assembly to the discharge opening 

in the ventilator housing. Use the sheet metal screws (#8 x ¼) 

provided.

5.  Remove  the  junction  box  cover  and  appropriate  electrical 

knockout from the ventilator for access to the wiring.

6.  Install the proper ductwork (FIGURE 3). Use duct tape to make 

connections secure and air tight.

7.  Lift the ventilator into position and feed the house wiring through 

the ventilator’s electrical knockout.

8.  Tighten the (4) mounting screws to secure the ventilator to the 

cabinet. Be sure the screw heads remain in the narrow end of 

the keyhole slots (FIGURE 2).

9.  Complete the electrical wiring in the junction box, according to 

the National Electrical Code and local ordinances.

10. Replace the junction box cover.

11. Install a 75-Watt (maximum) light bulb.

12. Replace the blower/lens cover and filters.