Broan nortron 21D10 Скачать руководство пользователя страница 10

- 10 -

9. S

ERVICE

 P

ARTS

FL0019

1

2

3

4

5

6

8

7

10

13

14

15

19

20

9

11

12

16

17

18

REPLACEMENT PARTS

KEY NO.

PART NO.

DESCRIPTION

1

30270032

Automatic Limit

2

30274132

Relay (KC1, KC2, KC3, KC4 and KC5)

3

30280021

Thermostat Indicator Light 

4

30030006

Heat Activation Switch

5

30030025

Speed Selection Switch

6

30280020

Manual Reset Limit

7

30274191

Breaker 50 Amps

8

30274192

Breaker 25 Amps

9

30010010

Fiberglass Filter 20” x 20” x 1” 
(508 mm x 508 mm x 25 mm)

10

10941385

Service Blower Assembly for 21ECM10

11

10941291

Service Blower Assembly for 21ECM15

12

10941292

Service Blower Assembly for 21ECM18
21ECM20 and 21ECM23

* Not illustrated

R

EPLACEMENT

 

PARTS

 

AND

 

REPAIRS

I

N

 

ORDER

 

TO

 

ENSURE

 

YOUR

 

UNIT

 

REMAINS

 

IN

 

GOOD

 

WORKING

 

CONDITION

YOU

 

MUST

 

USE

 B

ROAN

-N

U

T

ONE

 

GENUINE

 

REPLACEMENT

 

PARTS

 

ONLY

. T

HE

 B

ROAN

-N

U

T

ONE

 

GENUINE

 

REPLACEMENT

 

PARTS

 

ARE

 

SPECIALLY

 

DESIGNED

 

FOR

 

EACH

 

UNIT

 

AND

 

ARE

 

MANUFACTURED

 

TO

 

COMPLY

 

WITH

 

ALL

 

THE

 

APPLICABLE

 

CERTIFICATION

 

STANDARDS

 

AND

 

MAINTAIN

 

A

 

HIGH

 

STANDARD

 

OF

 

SAFETY

. A

NY

 

THIRD

 

PARTY

 

REPLACEMENT

 

PART

 

USED

 

MAY

 

CAUSE

 

SERIOUS

 

DAMAGE

 

AND

 

DRASTICALLY

 

REDUCE

 

THE

 

PERFORMANCE

 

LEVEL

 

OF

 

YOUR

 

UNIT

WHICH

 

WILL

 

RESULT

 

IN

 

PREMATURE

 

FAILING

. A

LSO

, B

ROAN

-N

U

T

ONE

 

RECOMMENDS

 

TO

 

CONTACT

 

A

 

CERTIFIED

 

SERVICE

 

DEPOT

 

FOR

 

ALL

 

REPLACEMENT

 

PARTS

 

AND

 

REPAIRS

.

REPLACEMENT PARTS

KEY NO.

PART NO.

DESCRIPTION

13

624665

Electronic Control

14

30274131

Relay (K7)

15

30300022

Transformer 240 V

16

10941384

Motor 1/3 HP 208/230 V for 21ECM10

17

10941289

Motor 1/3 HP 208/230 V for 21ECM15

18

10941290

Motor 1/3 HP 208/230 V for 21ECM18,
21ECM20 and 21ECM23

19

10940080

Element Assembly 5000 W, 240 V

20

10940081

Element Assembly 4500 W, 240 V

*

624664

Daughterboard (21ECM23 only)

*

10941383

Service Door ECM Series

*

FK120 

ECM

120 Volt Kit (optional, purchase separately)

Содержание nortron 21D10

Страница 1: ...uTone Canada Inc Mississauga Ontario www broan ca 877 896 1119 INSTALLATION AND USER MANUAL IMPORTANT READ AND SAVE THESE INSTRUCTIONS 30042480A MODELS 21ECM10 21ECM15 21ECM18 21ECM20 AND 21ECM23 M A DE IN CANA D A F A B R I Q UÉ AU CA N A D A ...

Страница 2: ...ature furnace failure thus voiding the warranty Do not block the combustion air openings in the furnace Any blockage will result in improper overheat situation and may result in a fire hazard and or cause bodily harm The unit must have an uninterrupted or unbroken electrical ground to minimize personal injury if an electrical fault should occur When performing electrical connection the ground cond...

Страница 3: ...OWERED FURNACE HUMIDIFIERS 7 7 4 INTERLOCK CONNECTION 7 8 WIRING DIAGRAMS 8 9 9 SERVICE PARTS 10 10 MAINTENANCE 11 11 TROUBLESHOOTING 11 12 WARRANTY 12 1 DIMENSIONS FK0003A FRONT VIEW RIGHT SIDE VIEW REAR VIEW LEFT SIDE VIEW TOP VIEW 1 38 mm 1 38 mm 20 508 mm 20 508 mm 1 25 mm 39 991 mm FILTER FRAME EITHER SIDE REAR OR BOTTOM 1 x 1 KO 38 mm x 38 mm 1 x 1 KO 38 mm x 38 mm 1 x 1 KO 38 mm x 38 mm WIR...

Страница 4: ...l be indicated on the data label attached to the furnace 4 TEMPERATURE RISE Furnaces are shipped to operate at 0 20 W C 50 Pa external static pressure They are certified for operation up to 0 50 W C 125 Pa Check below for temperature rise table on specification chart and if necessary adjust the unit to match 5 SERVICE CLEARANCE Units are serviced from the FRONT Leave at least 24 610 mm clearance i...

Страница 5: ...esponse when the thermostat calls for heat When SLOW is selected it takes more time to bring all the elements online When FAST is selected the heating elements come online faster 4 BREAKERS FD0001 ECM Series furnaces are equipped with breakers located on the front panel of the unit These devices protect the heating elements from overcurrent If this situation occurs the breakers will open to cut th...

Страница 6: ...ass through the floor of the structure Recommended size of a floor opening 14 x 14 362 mm x 362 mm The duct system must be designed so that the external static pressure of the system does not exceed the maximum external static pressure of 0 50 W C 125 Pa SHALLOW DUCT AREA REQUIREMENTS DUCT DEPTH DUCT WIDTH 4 102 mm 16 406 mm 5 127 mm 13 330 mm 6 152 mm 10 254 mm 5 INSTALLATION NOTES 5 1 COLD AIR R...

Страница 7: ...e closed in summer directing all air flow through the coil In winter the damper would be open to allow air to bypass the coil Typical air conditioning field wiring connections are shown in the diagram at right FURNACE THERMOSTAT CONDENSER FE0001A WIRING COLOR CODE C G R W1 W2 Y COMMON GREEN RED WHITE WHITE BLUE OPTIONAL YELLOW 7 3 ELECTRONIC AIR CLEANERS AND OR POWERED FURNACE HUMIDIFIERS These un...

Страница 8: ... FOR FAN CALL FOR COOL REVERSING VALVE CALL FOR HEAT 1 CALL FOR HEAT 2 CALL FOR COOL 1 Y1 W2 W1 O Y Y2 G R C Heat Activation PP PP GR HEAT INDICATOR PP B X13 COM X13 HEAT X13 COOL XFMR L1 L1 L2 COM L2 L2 R R B B B O W Class 2 Transformer Pri 240 V 60 Hz Sec 24 V 60 Hz 40 VA T R B Y Y TB Speed Selector MED R Y R MED Y LO BL LO NC B HI M NC M 4 3 2 1 N G L C C COM L LINE G GROUND N NEUTRAL O BL BL P...

Страница 9: ...V DC KC1 COM HEAT 1 COM COM 24V DC KC2 HEAT 2 24V DC KC3 HEAT 3 NO COM 24V DC KC4 HEAT 4 B2 50 A B1 50 A NO COM 24V DC KC5 HEAT 5 B3 25 A R R R R R GR BR P P PP PP W B B W B W W B W B 24V DC NC O BL BL P 5 1 2 4 3 6 W W K7 B B B LO TB Speed Selector MED R Y 23 KW 240 VAC Single phase 5 R LO Y MED BL MED NC B HI M 4 3 2 1 N G L C M C COM L LINE G GROUND N NEUTRAL 1 LO 2 MED HI 3 MED HI 4 HI 5 HI B ...

Страница 10: ...NT PARTS ONLY THE BROAN NUTONE GENUINE REPLACEMENT PARTS ARE SPECIALLY DESIGNED FOR EACH UNIT AND ARE MANUFACTURED TO COMPLY WITH ALL THE APPLICABLE CERTIFICATION STANDARDS AND MAINTAIN A HIGH STANDARD OF SAFETY ANY THIRD PARTY REPLACEMENT PART USED MAY CAUSE SERIOUS DAMAGE AND DRASTICALLY REDUCE THE PERFORMANCE LEVEL OF YOUR UNIT WHICH WILL RESULT IN PREMATURE FAILING ALSO BROAN NUTONE RECOMMENDS...

Страница 11: ...open contact Electronic control 4 Motor going on and off in short cycles or in too long cycles Heat anticipator in thermostat incorrectly set or may be defective 5 The thermostat must be set much higher or lower than the desired house temperature The thermostat is not leveled or out of calibration 6 Not enough heat One or more defective elements or sequencers HEAT ACTIVATION switch set in LOW posi...

Страница 12: ... of repaired part or replaced product mentioned above and for reinstallation costs The duration of any implied warranty is limited to the sixty month period as specified for the express warranty Some jurisdictions do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you BROAN NUTONE SOBLIGATIONTOREPAIRORREPLACE ATBROAN NUTONE SOPTION SHALLBETHEPURC...

Страница 13: ...Canada Inc Mississauga Ontario www broan ca 877 896 1119 GUIDE D INSTALLATION ET D UTILISATION IMPORTANT VEUILLEZ LIRE ET CONSERVER CES DIRECTIVES 30042480A MODÈLES 21ECM10 21ECM15 21ECM18 21ECM20 ET 21ECM23 M A DE IN CANA D A F A B R I Q UÉ AU CA N A D A ...

Страница 14: ... annule la garantie Ne pas obstruer les ouvertures de circulation d air de la fournaise Toute obstruction résultera en une surchauffe inadéquate et accroît les risques d incendie et ou de dommages corporels Cet appareil doit être relié à une mise à la terre ininterrompue pour minimiser les risques de blessures corporelles si jamais un problème électrique se produisait Lors du raccordement électriq...

Страница 15: ...9 9 PIÈCES DE REMPLACEMENT 10 10 ENTRETIEN 11 11 DÉPANNAGE 11 12 GARANTIE 12 1 DIMENSIONS FK0003F VUE AVANT VUE LATÉRALE DROITE VUE ARRIÈRE VUE LATÉRALE GAUCHE VUE DU DESSUS 1 po 38 mm 1 po 38 mm 20 po 508 mm 20 po 508 mm 1 po 25 mm 39 po 991 mm CADRE DU FILTRE SUR UN DES COTÉS À L ARRIÈRE OU EN DESSOUS OUVERTURE PRÉAMORCÉE 1 po x 1 po 38 mm x 38 mm OUVERTURE PRÉAMORCÉE 1 po x 1 po 38 mm x 38 mm O...

Страница 16: ...édition les fournaises sont réglées pour fonctionner à une pression statique externe de 0 20 po de colonne d eau 50 Pa Elles sont certifiées pour fonctionner à une pression allant jusqu à 0 50 po de colonne d eau 125 Pa Consulter le tableau ci dessous d augmentation de température au tableau des spécifications et au besoin ajuster l appareil en conséquence 5 DÉGAGEMENT DE MAINTENANCE L entretien s...

Страница 17: ...Le ventilateur tourne en vitesse plus élevée Au printemps ou à l automne il sera peut être nécessaire d obtenir une réponse moins rapide lorsque le thermostat commandera du chauffage Lorsque LENTE est sélectionnée les éléments de chauffage sont alimentés plus lentement Lorsque RAPIDE est sélectionnée les éléments de chauffage sont alimentés plus rapidement 4 DISJONCTEURS FD0001 Les fournaises de l...

Страница 18: ...ur de la fournaise Suivre les schémas fournis avec le thermostat Garder en mémoire que les bornes R et W commandent le chauffage à un étage et les bornes R et Y la climatisation La climatisation à une consigne utilise Y Y2 comme première et unique étape La climatisation à deux consignes utilise Y1 comme première étape et Y Y2 comme deuxième étape Vous assurer que le thermostat soit fixé au niveau ...

Страница 19: ...fage Fermer le clapet l été pour diriger le débit d air à travers le serpentin Ouvrir le clapet l hiver pour permettre à l air de dériver du serpentin Le schéma ci contre illustre le branchement de la climatisation FOURNAISE THERMOSTAT CONDENSATEUR FE0001F CODE DE COULEUR DES FILS C G R W1 W2 Y COMMUN VERT ROUGE BLANC BLANC BLEU OPTIONNEL JAUNE 7 3 PURIFICATEURS D AIR ÉLECTRONIQUES ET OU HUMIDIFIC...

Страница 20: ...TÉMOIN DE CHAUFFAGE P N X13 COM X13 HEAT X13 COOL XFMR L1 L1 L2 COM L2 L2 R R N N N O B R B J J 24V CC BASSE 5 TB Sélecteur de vitesse MOY R J R BASSE J MOYENNE BL MOY SC N HAUTE M SC M 4 3 2 1 N G L C C COM L LIGNE G MISE À LA TERRE N NEUTRE 1 BASSE 2 MOY H 3 MOY H 4 HAUTE 5 HAUTE O BL BL RO 5 1 2 4 3 6 B B K7 N R L2 N G R R R N N N R N N HEAT 3 E ARTP R HEAT 1 E ARTP R HEAT 2 E ARTP R N N N B NO...

Страница 21: ...N NOIR J JAUNE O ORANGE P POURPRE R ROUGE RO ROSE FE0050F Pour utiliser un thermostat à double consigne ou d extérieur effectuer le raccordement entre W1 et W2 S assurer que le commutateur de l Activation du chauffage est en position Lente Basse tension Haute tension Haute tension 8 AWG 1 Si un ou des fils originaux doivent être remplacés un fil équivalent et reconnu par les normes et les autorité...

Страница 22: ...ormateur de 240 V 16 10941384 Moteur 1 3 HP 208 230 V pour 21ECM10 17 10941289 Moteur 1 3 HP 208 230 V pour 21ECM15 18 10941290 Moteur 1 3 HP 208 230 V pour 21ECM18 21ECM20 et 21ECM23 19 10940080 Ensemble d éléments de 5000 W 240 V 20 10940081 Ensemble d éléments de 4500 W 240 V 624664 Carte fille 21ECM23 seulement 10941383 Porte de remplacement pour la série ECM FK120 ECM Adaptateur 120 volts opt...

Страница 23: ...icipateur de chaleur du thermostat est mal réglé ou est défectueux 5 Le thermostat doit être réglé à une température beaucoup plus haute ou plus basse que celle désirée dans la maison Le thermostat n est pas à niveau ou est mal calibré 6 Pas assez de chaleur Un ou plusieurs éléments ou relais Commutateur ACTIVATION DU CHAUFFAGE réglé en position LENTE Les disjoncteurs thermiques coupent le circuit...

Страница 24: ...lus haut ou pour le coût de réinstallation La durée de toute garantie implicite est limitée à une période de un an tel qu elle est spécifiée pour la garantie exprimée Certaines juridictions ne permettent pas de limite de temps sur les garanties implicites Si tel est le cas veuillez ne pas tenir compte de la dernière limite décrite ci dessus L ENGAGEMENT DE BROAN NUTONE DE RÉPARER OU DE REMPLACER A...

Отзывы: