Installation Guide

Page 2

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the service 

disconnecting means cannot be locked, securely fasten a 

prominent warning device, such as a tag, to the service panel.

3. Installation work and electrical wiring must be done by a 

qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction codes and 

standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration and 

Air Conditioning Engineers (ASHRAE), and the local code 

authorities.

5. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7.  Acceptable for use over a tub or shower (in the ceiling only) 

when connected to a GFCI (Ground Fault Circuit Interrupter) - 

protected branch circuit.

8.  This unit must be grounded.

Typical Installation

CAUTION

1

.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.  When installed in a wall or sloped ceiling, the duct connector 

must point up.

3.  To avoid motor bearing damage and noisy and/or unbalanced  

impellers, keep drywall spray, construction dust, etc. off power 

unit.

4.  Please read specification label on product for further 

information and requirements.

45°

45°

NOT FOR USE IN A COOKING AREA

 Do not install above or inside this area

Floor

Cooking
Equipment

Joists    I-Joists          Trusses

•  Attaches to 2" x 4" or greater 

wall studs or ceiling joists.

*Purchase

separately.

INSULATION* 

(Place around and 

over Fan Housing.)

ROOF CAP*

(with built-in

damper)

FAN

HOUSING

POWER

CABLE*

ROUND

DUCT*

ROUND

ELBOWS*

Seal gaps

around

Housing.

Seal duct

joints with

tape.

OR

Keep duct

runs short.

   WALL CAP* 

(with built-in

damper)

CEILING INSTALLATION SHOWN

The ducting from this fan to the outside of the building has a strong effect on the 

air flow, noise and energy use of the fan. Use the shortest, straighest duct routing 

possible for best performance, and avoid installing the fan with smaller ducts than 

recommended. Insulation around the ducts can reduce energy loss and inhibit mold 

growth. Fans installed with existing ducts may not achieve their rated airflow.
4-inch round rigid metal duct is recommended for best performance.

Содержание LP50100DC

Страница 1: ...N LEA Y CONSERVE ESTAS INSTRUCCIONES Aviso al instalador deje esta gu a con el due o de la casa Registre su producto en l nea en www broan com register ndice Advertencias y precauciones 14 Instalaci...

Страница 2: ...to the outdoors 7 Acceptable for use over a tub or shower in the ceiling only when connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit 8 This unit must be grounded Typical In...

Страница 3: ...insulation stripper Wire cutter Materials needed 4 round metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damp...

Страница 4: ...tallation 3 Install Ducting 2 Install in Wall or Ceiling UP Wall Ceiling OR 1 2 Insert tab into slot in housing 1 2 Tape 4 Ducting Wire 3 places Screw through housing on opposite side Tighten Screw in...

Страница 5: ...nnectors to secure wiring to the Knockout Plate Connect wires as shown in wiring diagram Attach cable clamp to Knockout Plate Knockout Plate may be oriented as desired Connect wires ON OFF SWITCH purc...

Страница 6: ...uct REMOVE MASK BEFORE IN STALLIN G GRIL LE Utiliser ce couvercle pour emp cher la poussi re de construction le pl tre ou la peinture d endommager l int rieur du pro duit ENLEVER LE COUVERCLE AVANT D...

Страница 7: ...earings are making excessive or unusual noises replace the Blower Assembly Troubleshooting Symptom The fan does not run Check for an open fuse or circuit breaker in the building s service panel Check...

Отзывы: