Broan HUMIDITY SENSING FAN QTRE100S Скачать руководство пользователя страница 4

Page

MODEL   QTRE100S  

SERVICE PARTS

99044368A

 

Key No.  Part No. 

Description

 

97016466  Housing

 

97016449  Duct Connector - 4”

 

98010102  Wiring Plate

 

99170245  Screw, #8-18 X .375

 

97017085  Wire Panel/Harness Assembly

 

97017999  Motor/Blower Wheel Assembly

 

97017478  Motor Plate & Control Assembly

 

97017998  Blower Assembly

 

 

 

  (includes key nos. 6 & 7)

 

97017420  Grille Assembly 

 

 

 

  (includes key nos. 8 & 9)

 

99140199  Grille Spring (2 req’d)

 

10 

97018014  Spacer (2 supplied)

 

11 

QTHB1 

Hanger Bar Kit

 

12 

99420665  Thumbscrew, #8-18 x .375

Order service parts by “Part No.” - not by “Key No.”

INSTALL GRILLE

6.  Finish ceiling.

 

Install ceiling material. Cut out around housing.

7.  Attach grille to 

housing.

 

Squeeze grille springs 

and insert them into slots 

on each side of housing.

8.  Push grille against 

ceiling.

WARRANTY

Replacement parts 

can be ordered on 

our website. Please 

visit us at www.

broan.com

SERVICE NOTE

To remove Blower Assembly:

Unplug motor. Remove 

thumbscrew (12)  from motor 

plate flange. Find the single 

TAB

 on the motor plate 

(located next to the receptacle). 

Push up near motor plate tab 

while pushing out on side of 

housing. Or insert a straight-

blade screwdriver into slot in 

housing (next to tab) and twist 

screwdriver.

BROAN THREE YEAR LIMITED WARRANTY

Broan warrants to the original consumer purchaser of its products that such products will 

be free from defects in materials or workmanship for a period of three years from the date 

of original purchase. ThERE ARE nO OThER WARRAnTiES, EXPRESS OR iMPLiED, 

inCLUDing, BUT nOT LiMiTED TO, iMPLiED WARRAnTiES OF MERChAnTABiLiTY 

OR FiTnESS FOR A PARTiCULAR PURPOSE.

During this three-year period, Broan will, at its option, repair or replace, without charge, 

any product or part which is found to be defective under normal use and service.

ThiS WARRAnTY DOES nOT EXTEnD TO FLUORESCEnT LAMP STARTERS AnD 

TUBES. This warranty does not cover (a) normal maintenance and service or (b) any 

products or parts which have been subject to misuse, negligence, accident, improper 

maintenance or repair (other than by Broan), faulty installation or installation contrary 

to recommended installation instructions.

The duration of an implied warranty is limited to the three-year period as specified for the 

express warranty. Some states do not allow limitation on how long an implied warranty 

lasts, so the above limitation may not apply to you.

BROAn’S OBLigATiOn TO REPAiR OR REPLACE, AT BROAn’S OPTiOn, ShALL 

BE ThE PURChASER’S SOLE AnD EXCLUSiVE REMEDY UnDER ThiS WAR-

RAnTY. BROAn ShALL nOT BE LiABLE FOR inCiDEnTAL, COnSEQUEnTiAL OR 

SPECiAL DAMAgES ARiSing OUT OF OR in COnnECTiOn WiTh PRODUCT USE 

OR PERFORMAnCE. Some states do not allow the exclusion or limitation of incidental 

or consequential damages, so the above limitation may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights, which 

vary from state to state. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan at the address or telephone 

number stated below, (b) give the model number and part identification and (c) describe 

the nature of any defect in the product or part. At the time of requesting warranty service, 

you must present evidence of the original purchase date.

Broan-nuTone LLC    hartford, Wisconsin    www.broan.com    800-558-1711

Содержание HUMIDITY SENSING FAN QTRE100S

Страница 1: ...keep drywall spray construction dust etc off power unit 4 Please read specification label on product for further information and requirements HUMIDITY SENSING FAN READ AND SAVE THESE INSTRUCTIONS CLE...

Страница 2: ...JOIST shown requires use of SPACERS included between the highest hole of each mounting flange and the I joist OR Locate unit above GFCI protected circuit required or within 5 feet of shower head Loca...

Страница 3: ...d hanger bars screw 2 hole for optional screw mounting 4 mounting channel 2 nail 4 bottom edge of framing 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL ap...

Страница 4: ...OR FITNESS FOR A PARTICULAR PURPOSE During this three year period Broan will at its option repair or replace without charge any product or part which is found to be defective under normal use and ser...

Страница 5: ...equilibrados mantenga la unidad de accionamiento al resguardo de rociados de yeso polvos de construcci n etc 4 L ase la etiqueta de especificaciones que tiene el producto para ver informaci n y requi...

Страница 6: ...requiere utilizar SEPARADORES incluidos entre el orificio m s alto de cada brida de montaje y la vigueta I O BIEN Coloque la unidad sobre o dentro de una distancia de 1 5 m 5 pies de la cabeza de la...

Страница 7: ...icos Extienda el cableado de la casa de 120 V CA al lugar de la instalaci n Utilice una conexi n aprobada por UL para afianzar el cableado de la casa a la placa de cableado Conecte los cables tal como...

Страница 8: ...a original NO EXISTEN OTRAS GARANT AS EXPRE SAS NI IMPL CITAS INCLUIDAS PERO SIN LIMITARSEA GARANT AS IMPL CITAS DE COMERCIALIZACI N O IDONEIDAD PARA UN PROP SITO PARTICULAR Durante este per odo de tr...

Отзывы: