3. MAINTENANCE (

CONT

D

)

3.3 A

NNUAL

 

MAINTENANCE

 (F

ALL

)

Repeat steps 1 to 6 from the Section 3.1 and continue with the following steps:

1.  Clean the heat recovery core:

 • Remove 

core.

 

• 

Let it soak in a mixture of cold or lukewarm water and mild soap (dishwashing liquid).

 • Rinse 

thoroughly.

 

• 

Shake the core to remove excess water and let it dry.

2.  Clean blower assembly.

 

• 

Remove dust using a vacuum cleaner with a soft brush attachment.

3.  Reassemble the components.

4.  Reconnect power supply.

CAUTION

Hot water and a strong detergent will damage the heat recovery core.

3.3.1 H

EAT

 

RECOVERY

 

CORE

Repeat steps 1 to 6 from the Section 3.1 and continue with the following steps:

1.  Clean the energy recovery core:

 • Remove 

core.

 

• 

Remove dust using a vacuum cleaner with a soft brush attachment.

2.  Clean blower assembly.

 

• 

Remove dust using a vacuum cleaner with a soft brush attachment.

3.  Reassemble the components.

4.  Reconnect power supply.

CAUTION

The energy recovery core cannot be washed with water.

3.3.2 E

NERGY

 

RECOVERY

 

CORE

Содержание HRV190S Series

Страница 1: ...FFICIENCY GUIDELINES SET BY NATURAL RESOURCES CANADA AND THE US EPA THEY MEET ENERGY STAR REQUIREMENTS ONLY WHEN USED IN CANADA HRV150S VB0234 HRV190S READ AND SAVE THESE INSTRUCTIONS Broan NuTone LLC Hartford Wisconsin www broan com 1 877 862 7626 REGISTER YOUR PRODUCT ONLINE AT www broan com register For additional information visit www broan com ...

Страница 2: ...s including possibility of death Denotes an instruction which if not followed may severely damage the unit and or its components WARNING Some activities create dust or vapors which may damage your unit You must therefore turn off and unplug your unit in the following situations Major renovation work Sanding e g gypsum joints etc Housing construction Varnishing During very heavy snowstorms or rain ...

Страница 3: ...oor temperature is below 23 F recovery of heat or energy creates frost in the module To maintain its proper operation the unit is programmed to defrost the recovery module The defrost frequency varies according to the outdoor temperature Defrost lasts 7 minutes for HRV150S 6 minutes for HRV190S and 10 minutes for ERV180S models or 10 minutes for all models if set on Extented Defrost During the def...

Страница 4: ... control LED will light GREEN or AMBER for 5 seconds and then will shut off for 2 seconds After that the LED will light RED for the rest of the booting sequence During this RED light phase the unit is checking and resetting the motorized damper position Once the motorized damper position completely set the RED light turns off and the booting sequence is done NOTE No command will be taken until the...

Страница 5: ...ONTHS Regular maintenance should be performed every 3 months Annual maintenance should take place every Fall season 1 Disconnect power supply 2 Unlatch the door Lift the panel towards you Hold it firmly and hit on the right side of the panel The door will slide to the left 3 Clean the inside of the door with a damp cloth 4 Clean filters Remove filters Vacuum to remove most of the dust Wash with a ...

Страница 6: ...terior air intake hood Make sure there are no leaves twigs ice or snow that could be drawn into the vent Clean if necessary 7 Reassemble the components 8 Reconnect power supply CAUTION Even a partial blocking of this air vent could cause the unit to malfunction VO0230 ...

Страница 7: ... soft brush attachment 3 Reassemble the components 4 Reconnect power supply CAUTION Hot water and a strong detergent will damage the heat recovery core 3 3 1 HEAT RECOVERY CORE Repeat steps 1 to 6 from the Section 3 1 and continue with the following steps 1 Clean the energy recovery core Remove core Remove dust using a vacuum cleaner with a soft brush attachment 2 Clean blower assembly Remove dust...

Страница 8: ...ds are not blocked Operate the unit at low speed Have the system s balancing checked Have the unit s defrost system checked Install a duct heater For wall controls problems refer to the Troubleshooting section in the Main and auxiliary wall controls user guide included with the ventilation unit and also available at www broan com If the problem is still not solved contact your installer REPLACEMEN...

Отзывы: