background image

3

1.  DEFROST MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2. CONTROLS  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

 2.1 

I

NTEGRATED

 C

ONTROL

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

 2.2 

B

OOT

 S

EQUENCE

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

 2.3 

O

PTIONAL

 M

AIN

 

AND

 A

UXILIARY

 C

ONTROLS

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

3. MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-7

 3.1 

U

NIT

 D

ESCRIPTION

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

 3.1 

E

VERY

 T

HREE

 M

ONTHS

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-6

 3.2 

A

NNUAL

 M

AINTENANCE

 (F

ALL

)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

 3.2.1 

H

EAT

 R

ECOVERY

 C

ORE

   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

 3.2.2 

E

NERGY

 R

ECOVERY

 C

ORE

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

4. TROUBLESHOOTING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

TABLE OF CONTENTS

1. DEFROST 

MODE

When the outdoor temperature is below 23°F, recovery (of heat or energy) creates frost in the 
module. To maintain its proper operation, the unit is programmed to defrost the recovery module. 
The defrost frequency varies according to the outdoor temperature. Defrost lasts 7 minutes for 
HRV150S, 6 minutes for HRV190S and 10 minutes for ERV180S models (or 10 minutes for all 
models if set on “Extented Defrost”). During the defrost cycle, the unit shifts to maximum speed and 
the dampers close.

After defrosting, the unit returns to the operating mode selected by the user.

Содержание HRV150S

Страница 1: ...LER 22644 REV 03 ERV180S HRV150S VB0297 HRV190S READ AND SAVE THESE INSTRUCTIONS Broan NuTone LLC Hartford Wisconsin www broan com 1 877 862 7626 REGISTER YOUR PRODUCT ONLINE AT www broan com register...

Страница 2: ...including possibility of death Denotes an instruction which if not followed may severely damage the unit and or its components WARNING Some activities create dust or vapors which may damage your unit...

Страница 3: ...or temperature is below 23 F recovery of heat or energy creates frost in the module To maintain its proper operation the unit is programmed to defrost the recovery module The defrost frequency varies...

Страница 4: ...control LED will light GREEN or AMBER for 5 seconds and then will shut off for 2 seconds After that the LED will light RED for the rest of the booting sequence During this RED light phase the unit is...

Страница 5: ...NTHS Regular maintenance should be performed every 3 months Annual maintenance should take place every Fall season 1 Disconnect power supply 2 Unlatch the door Lift the panel towards you Hold it firml...

Страница 6: ...erior air intake hood Make sure there are no leaves twigs ice or snow that could be drawn into the vent Clean if necessary 7 Reassemble the components 8 Reconnect power supply CAUTION Even a partial b...

Страница 7: ...soft brush attachment 3 Reassemble the components 4 Reconnect power supply CAUTION Hot water and a strong detergent will damage the heat recovery core 3 3 1 HEAT RECOVERY CORE Repeat steps 1 to 6 from...

Страница 8: ...s are not blocked Operate the unit at low speed Have the system s balancing checked Have the unit s defrost system checked Install a duct heater For wall controls problems refer to the Troubleshooting...