QP3 SERIES
Page 5
3¼” X 10”
HORIZONTAL DUCTING
CABINET
BOTTOM
CABINET FRONT
HORIZONTAL DUCT
ACCESS HOLE
5¼"
5¼"
HOOD
MOUNTING
SCREWS (5)
ELECTRICAL
ACCESS
HOLE
(in wall)
4"
CENTER
LINE
WOOD SHIMS
(recessed-bottom
cabinets only)
6
7
/
8
"
1
3
/
8
"
3
/
8
"
*
17
5/8
" (42" hood)
17
5/8
" (42" hood)
14
5/8
" (36" hood)
14
5/8
" (36" hood)
11
5/8
" (30" hood)
11
5/8
" (30" hood)
3
5
/
8
"
MAKE-UP AIR
DAMPER ELECTRICAL
CONNECTION HOLE
(in wall)
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
2
1
/
8
"
6
7
/
8
"
10
7
/
8
"
2
5
/
8
"
HOOD MOUNTING SCREWS (5)
4
5
/
8
"
8" DIA.
HOLE
7-IN. ROUND
DUCT
ACCESS
HOLE
7-IN. ROUND
DUCT
ACCESS
HOLE
11"
17
5/8
" (42" hood)
17
5/8
" (42" hood)
14
5/8
" (36" hood)
14
5/8
" (36" hood)
11
5/8
" (30" hood)
11
5/8
" (30" hood)
*
7-IN. ROUND
DUCTING
5
Use the proper diagram below, for placement of ductwork
and electrical cutout in cabinet or wall. For a non-ducted
installation, DO NOT cut a duct access hole.
VERTICAL DUCT
ACCESS HOLE
¾"
10
7/8
"
5¼"
5¼"
CENTER
LINE
HOOD MOUNTING SCREWS (5)
ELECTRICAL
ACCESS HOLE
(in cabinet bottom)
WOOD SHIMS
(recessed-bottom
cabinets only)
CABINET FRONT
CABINET
BOTTOM
17
5/8
" (42" hood)
4½"
2
1/8
"
2
5/8
"
11"
6
7/8
"
*
17
5/8
" (42" hood)
14
5/8
" (36" hood)
14
5/8
" (36" hood)
11
5/8
" (30" hood)
11
5/8
" (30" hood)
3¼” X 10”
VERTICAL DUCTING
*
Note the extra wood shim and mounting screw near the
cabinet front, on the cabinet center line.
To change the depth of bulb sockets:
- Remove bottom pan (See Step 10).
- Remove 2
Light Panel Screws and Light Panel. Set
screws aside.
- Loosen 2
Screws holding Lamp Socket Bracket to
Light Panel.
- Adjust socket/bracket to desired depth.
- Re-tighten screws securely.
- Re-attach light panel and bottom pan.
LAMP SOCKET
BRACKET
SCREWS
LIGHT
PANEL
SOFFIT
24" - 30" ABOVE
COOKING SURFACE
CABINET
3¼" X 10" DUCT
(For horizontal discharge)
WALL CAP
ROOF CAP
3¼" X 10" or
7" ROUND DUCT
(For vertical
discharge)
HOUSE WIRING
(Top or Back of hood)
HOOD
HOOD
1
Determine whether hood will discharge vertically (3¼” x
10” or 7” Round), or horizontally (3¼” x 10” only).
INSTALL THE DUCTWORK
(Ducted Hoods Only)
2
Decide where the ductwork will run between the hood
and the outside.
3
Choose a straight, short duct run to allow the hood to
perform most efficiently. Long duct runs, elbows and
transitions will reduce the performance of the hood. Use
as few of them as possible. Larger ductwork may be
required for best performance with longer duct runs.
4
Install wall cap or roof cap. Connect metal ductwork to
cap and work back towards the hood location. Use duct
tape to seal the joints between ductwork sections.
PREPARE HOOD LOCATION