6. PERMANENT FILTER (
OPTIONAL
)
The optional permanent filter can be used with or without the disposable bag. This
filter protects the motor and stops small particles from escaping to the outside of
the power unit wihout the need to replace it. The filter can be removed by means
of a pull-tab for cleaning (if need be). Be sure to reinstall properly. Appropriate
location is critical to insure proper protection of the motor.
6.1 INSTALLING FILTER
Squeeze the filter in order to place it over the bag
adapter (
A
). Let the filter prop against the unit wall by
releasing the squeezing pressure. Make sure to
place the rigid ring between the upper rib (
B
) and the
three bottom posts (
C
) to ensure proper sealing.
Make sure the filter is installed so that the pull tab (
D
)
is accessible for future filter removal.
6.2 REMOVING FILTER
Remove debris pail and disposable bag. Using pull
tab on edge of filter, pull and loosen filter from inlet
chamber wall by squeezing it on itself. Then, carefully
remove it from the unit.
6.3 CLEANING FILTER
Simply brush filter clean. If the filter is excessively soiled, wash in a mild detergent
and let it dry
completely
before putting it back in its place.
NOTE: The permanent filter (model PF450) may be purchased from your local
Broan-NuTone Sales Outlet. To locate your nearest Broan-NuTone Sales
Outlet, call toll free 1-888-882-7626.
AO002
8
B
C
A
AA0005
D
AO0027
CAUTION
Ensure that the filter is completely dry before reinstalling.
- 5 -