Broan BW5330SS Скачать руководство пользователя страница 1

Serial number: 

23452 rev. 01

WWW.BROAN.CA

CHIMNEY

RANGE HOOD

BW5330SS

INSTALLATION, USE 

AND CARE MANUAL

Содержание BW5330SS

Страница 1: ...Serial number 23452 rev 01 WWW BROAN CA CHIMNEY RANGE HOOD BW5330SS INSTALLATION USE AND CARE MANUAL...

Страница 2: ...f the surface element 1 For indoor use only 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbala...

Страница 3: ...efficiently Long duct runs elbows and transitions will reduce the performance of the hood Use as few of them as possible Larger ducting may be required for longer duct runs Install wall or roof cap C...

Страница 4: ...t in a risk of electric shock Consult a qualified electrician if the grounding instructions are not completely understood or if doubt exists as to whether the appliance is properly grounded Do not use...

Страница 5: ...ter downward Set filters aside HD1028 7 INSTALL 6 ROUND ADAPTER DAMPER Mount the 6 round adapter damper included using 4 no 8 x 5 16 screws included Seal the adapter damper to the hood using metal foi...

Страница 6: ...wer cord into the outlet Slide the 6 round flexible metal duct included in the non duct kit over the adapter without damper flaps on the hood attach with one included tie wrap Use metal foil duct tape...

Страница 7: ...RACKET BACK VIEW SLOTS UP LOWER FLUE Peel off both corners at the top of the upper flue NOTE For non ducted installation only remove enough plastic film to clear the louvers Position the lower flue ta...

Страница 8: ...acket using 2 no 8 x 5 16 mounting screws NOTE Duct or non duct plenum not shown in illustration to ease understanding Remove protective plastic film covering the upper flue and the hood HO0287 UPPER...

Страница 9: ...art It will then operate at the desired setting BLOWER OFF SPEED DECREASE PUSH BUTTON DOUBLE FUNCTION PUSH BUTTON Press on this push button to lower the blower speed If need be press until the blower...

Страница 10: ...leaners that contain bleach will attack stainless steel Any products containing chloride fluoride iodide bromide will deteriorate surfaces rapidly Any combustible products used for cleaning such as ac...

Страница 11: ...cally reduce the performance level of your unit which will result in premature failing Venmar Ventilation ULC recommends to contact a certified service depot for all replacement parts and repairs KEY...

Страница 12: ...insurance or other freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pa...

Страница 13: ...Num ro de s rie 23452 r v 01 WWW BROAN CA HOTTE CHEMIN E BW5330SS MANUEL D INSTALLATION D UTILISATION ET D ENTRETIEN...

Страница 14: ...uventilateur Nelaissezpaslagraisse s accumuler sur le ventilateur les filtres ou les conduits d vacuation d Utilisezlebonformatdecasserole Servez voustoujoursdecasseroles et d ustensiles appropri s la...

Страница 15: ...U CONDUIT D CORATIF SUP RIEUR SUPPORT DE MONTAGE DE LA HOTTE SUPPORT DE MONTAGE DU CONDUIT D CORATIF SUP RIEUR ADAPTATEUR VOLET DE 6 PO ROND 2 CHOISIR LE TYPE D INSTALLATION 2 1 INSTALLATION EN RECIRC...

Страница 16: ...ultez un lectricien si les instructions de mise la terre ne sont pas tout fait compr hensibles ou si un doute persiste quant savoir si l appareil est correctement reli la terre Ne pas utiliser de rall...

Страница 17: ...FENTES DU SUPPORT DE MONTAGE DU CONDUIT D CORATIF SUP RIEUR HJ0162 VOLETS Fixer l adaptateur volet de 6 po rond l aide de 4 vis n 8 x 5 16 po incluses Sceller l adaptateur la hotte l aide de ruban ad...

Страница 18: ...tation de la hotte dans la prise murale Glisser le conduit flexible rond de 6 po en m tal inclus dans le kit de recirculation par dessus l adaptateur sans les volets de la hotte et le fixer avec une a...

Страница 19: ...tique protectrice recouvrant le conduit d coratif inf rieur seulement Assembler le support de montage du conduit d coratif inf rieur celui ci l aide de 2 vis de montage n 8 x 5 16 po en vous assurant...

Страница 20: ...onduit de ventilation ou plenum non montr dans l illustration afin de faciliter la compr hension Retirer la pellicule de plastique protectrice recouvrant le conduit d coratif sup rieur et la hotte HO0...

Страница 21: ...R T DU VENTILATEUR DIMINUTION DE LA VITESSE BOUTON POUSSOIR DOUBLE FONCTION Pour diminuer la vitesse du ventilateur appuyer sur ce bouton poussoir Au besoin appuyer jusqu ce que le ventilateur s arr t...

Страница 22: ...ent Nettoyer les filtres fabriqu s enti rement de m tal l aide d un d tergent sans phosphate L utilisation d un d tergent avec phosphates ainsi que les conditions locales de l eau peuvent entra ner un...

Страница 23: ...ULC recommande galement de toujours vous r f rer une entreprise de services comp tente et reconnue par Venmar Ventilation ULC pour vos pi ces de remplacement et appels de service NON ILLUSTR 1 2 3 4...

Страница 24: ...ez envoyer le produit ou la pi ce la Soci t tel que la Soci t vous l indiquera vous devrez l emballer correctement La Soci t n est pas responsable des dommages subis lors du transport La Soci t se r s...