Prepare the Hood Location

NOTE: Before starting installation, read all the steps of these instructions.
Use the illustration below to identify your kitchen cabinet type.

EZ1 one-person installation system (BNDF1 Series only)

EZ1 installation is designed for use with kitchen cabinets that have the same width designation as 
the range hood width. If the cabinet is greater than 1/2” wider than the range hood width, please 
use the standard installation method.

1 ] 

Use the proper template for vertical OR horizontal disharge (included) for placement of 
ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a 
duct access hole, only cut the hole for electrical wiring. 

If replacing a hood and plan to use 

the existing duct and electrical, steps 2 to 5 may not be necessary. If so, skip to step 6.

2 ]  

Measure and mark the hood center line on cabinet bottom.

3 ]  

Align the center line on template with the hood center line marked on the bottom of the 
cabinet, placing the edge (where indicated) of the template against back wall. When using 
with framed cabinet for vertical exhaust installation, fold over rear edge of template equal 
to the depth of the cabinet frame at the wall (use graduations on template, 

C

 locations on 

template). Tape the template in place.

 

NOTE: When facing the installation, 

A

 and 

B

 (on template) must be at right.

This manual covers 2 kinds of installation: the standard (without EZ1 brackets) and the EZ1 
one-person installation system (using included template and brackets). Note that the EZ1 one-
person installation system is not available for BNSC1Series. For the standard installation, go to 
page 17.

FRAMED CABINET

FRAMELESS CABINET

CABINET FRONT

C

L

A

B

Apoyar este borde contra la pared de atrás

Place this edge against back wall

VERTICAL EXHAUST

A

S

A

A

V

RTICAL EX

= 3¼” x 10”

= 3¼” x 14”

RECTANGULAR DUCTING

7” ROUND DUCTING

OR

Use this template for marking;  do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

= 3¼ po x 10 po

= 3¼ po x 14 po

CONDUIT RECTANGULAIRE

CONDUIT ROND DE 7 PO

OU

= 3¼ pulg. x 10 pulg.

= 3¼ pulg. x 14 pulg.

CONDUCTO RECTANGULAR

CONDUCTO REDONDO

DE

 7 PULG.

O

Appuyer ce bord au mur arrière

Utiliser ce gabarit pour marquer vos repères;  ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados;  no trate de cortar el
agujero del conducto a través de la plantilla.

NOTA: To be translated in Spanish.

MARK WHERE INDICATED 

FOR

 THE APPROPRIATE SIZE DUCT OPENING

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON 

LE

 FORMAT DE CONDUIT UTILISÉ

TITLE TO BE TRANSLATED IN SPANISH

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

4¼”

10½”

14½”

8”

7½”

C

C

C

Bend template along graduated
scale when installing to framed
cabinet.

Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l’épaisseur du
décalage causé par le mur de 
l’armoire et plier le gabarit en 
conséquence.

To be translated in Spanish.

P

C

CABINET FRONT

C

L

A

B

VERTICAL EXHAUST

A

S

A

A

V

RTICAL EX

= 3¼” x 10”

= 3¼” x 14”

RECTANGULAR DUCTING

7” ROUND DUCTING

OR

Use this template for marking;  do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

= 3¼ po x 10 po

= 3¼ po x 14 po

CONDUIT RECTANGULAIRE

CONDUIT ROND DE 7 PO

OU

= 3¼ pulg. x 10 pulg.

= 3¼ pulg. x 14 pulg.

CONDUCTO RECTANGULAR

CONDUCTO REDONDO

DE

 7 PULG.

O

Utiliser ce gabarit pour marquer vos repères;  ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados;  no trate de cortar el
agujero del conducto a través de la plantilla.

NOTA: To be translated in Spanish.

MARK WHERE INDICATED 

FOR

 THE APPROPRIATE SIZE DUCT OPENING

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON 

LE

 FORMAT DE CONDUIT UTILISÉ

TITLE TO BE TRANSLATED IN SPANISH

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

4¼”

10½”

14½”

8”

7½”

C

C

C

Bend template along graduated
scale when installing to framed
cabinet.

Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l’épaisseur du
décalage causé par le mur de 
l’armoire et plier le gabarit en 
conséquence.

To be translated in Spanish.

A

C

ELECTRICAL

ACCESS HOLE

LOCATION (

A

)

(

IN

 

CABINET

 

BOTTOM

)

CENTER LINE

F

OLD

 

TEMPLATE

 

ALONG

 

GRADUATED

SCALE

 

WHEN

 

INSTALLING

 

TO

 

FRAMED

CABINET

.

VERTICAL EXHAUST 

DUCTING

Electrical access hol

A

 = single blower ho

B

 = double blower 

Centre du tr
d’alim

ELECTRICAL

ACCESS HOLE

LOCATION (

A

)

(

IN

 

WALL

)

CENTER LINE

A

C

L

A

B

Place this edge against
cabinet bottom.
Appuyer ce bord contre le bas
de l’armoire.
Apoyar este borde contra
la base del armario.

HORIZONTAL EXHAUST

T

T

= 3¼ pulg. x 10 pulg.
= 3¼ pulg. x 14 pulg.

CONDUCTO RECTANGULAR

= 3¼” x 10”
= 3¼” x 14”

RECTANGULAR DUCTING

= 3¼ po x 10 po
= 3¼ po x 14 po

CONDUIT RECTANGULAIRE

MARK WHERE INDICATED 

FOR

 THE APPROPRIATE SIZE DUCT OPENING

MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON 

LE

 FORMAT DE CONDUIT UTILISÉ

TITLE TO BE TRANSLATED IN SPANISH

Use this template for marking;  do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.

Utiliser ce gabarit pour marquer vos repères;  ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
 

être du format exact des conduits.

Use esta plantilla para crear marcados;  no trate de cortar el
agujero del conducto a través de la plantilla.
NOTA: To be translated in Spanish.

Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Centre du trou pour fil
d’alimentation électrique

A

 = hotte ventilateur simple

B

 = hotte ventilateur double

To be translated in Spanish
Electrical access hole center

A

 = single blower hood

B

 = double blower hood

Содержание BNDF1 Series

Страница 1: ...Serial number 99045659 002A RANGE HOOD Series BNDF1 and BNSC1 INSTALLATION USE AND CARE MANUAL WWW BROAN COM ...

Страница 2: ...Recommended Tools and Accessories for Installation 7 Install Ductwork Ducted Installations Only 7 Contents 8 Prepare the Hood 9 11 Prepare the Hood Location 12 EZ1 One Person Installation 12 14 Install the Hood EZ1 Brackets 15 16 Standard Installation 17 Install the Hood Standard Installation 18 Connect the Wiring 19 Light Bulbs BNCS1 Series only 20 Install the Filters 20 Wiring Diagrams 21 Servic...

Страница 3: ...ing equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting or drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the ...

Страница 4: ...and you know how to operate it B The fire is small and contained in the area where it started C The fire department has been called D You can fight the fire with your back to an exit Based on Kitchen Fire Safety Tips published by NFPA CAUTION For indoor use only For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors To avoid motor bearing damage and nois...

Страница 5: ...is activated a beep is heard and LED indicators light up to show the corresponding speed chosen lower LED for LOW speed lower and center LEDs for MEDIUM speed and all LEDs for HIGH speed When blower is on no matter the speed level press and hold this button until the beep sound ends this will turn off the blower and save this blower speed to memory LIGHT BUTTON When lights are OFF press once on th...

Страница 6: ...recirculation filters FAN BLADE The fan blade should be cleaned frequently Use a clean cloth soaked with warm detergent solution STAINLESS STEEL CLEANING Do Regularly wash with clean cloth or rag soaked with warm water and mild soap or liquid dish detergent Always clean in the direction of original polish lines Always rinse well with clear water 2 or 3 times after cleaning Wipe dry completely You ...

Страница 7: ...ABOVE COOKING SURFACE CABINET 3 X 10 DUCT FOR HORIZONTAL DISCHARGE WALL CAP ROOF CAP 3 X 10 OR 7 ROUND DUCT FOR VERTICAL DISCHARGE HOUSE WIRING TOP OR BACK OF HOOD HOOD NOTE Distances over 24 are at the installer and user discretion 1 Determine whether hood will discharge vertically 3 x 10 or 7 round or horizontally 3 x 10 only 2 Decide where the ductwork will run between the hood and the outdoors...

Страница 8: ... ne pas tenter de découper le trou pour le conduit à travers le gabarit NOTE Les découpes incluent le jeu nécessaire à l installation elles ne doivent pas être du format exact des conduits Use esta plantilla para crear marcados no trate de cortar el agujero del conducto a través de la plantilla NOTA To be translated in Spanish MARK WHERE INDICATED FOR THE APPROPRIATE SIZE DUCT OPENING MARQUER LES ...

Страница 9: ...ove the EZ1 brackets from inside the hood by cutting off the tie wrap no EZ1 brackets for BNSC1 Series Remove both screws holding damper assembly to hood Remove parts bag captured behind the damper assembly Remove damper assembly from inside the hood and keep the screws for further use 4 Remove the wiring cover shaded part on illustration below by sliding it out from the hood and set it aside B C ...

Страница 10: ...ble Knockout from top vertical exhaust or back horizontal exhaust of hood Install an appropriate strain relief 1 2 diameter not included 7 Remove 3 screws retaining the recirculation cover plate shaded part in illustration below to the hood Discard this plate with its screws 7 ROUND DUCT PLATE 2 SCREWS ELECTRICAL POWER CABLE KNOCKOUT RECIRCULATION COVER PLATE SCREWS ...

Страница 11: ...late can be installed up to 1 2 on either side of the hood center 7 ROUND KNOCKOUT PLATE ALSO REMOVE VERTICAL KNOCKOUT PLATE 3 X 10 VERTICAL KNOCKOUT PLATE 3 X 10 HORIZONTAL KNOCKOUT PLATE FIGURE 1 A 7 ROUND DUCT PLATE SCREWS FIGURE 3 3 X 10 DAMPER ASSEMBLY TOP BACK EDGE OF HOOD DAMPER FLAP PIVOT SCREWS FIGURE 2 A FIGURE 2 B FIGURE 1 B 3 X 10 DAMPER ASSEMBLY BACK OF HOOD DAMPER FLAP PIVOT SCREWS 9...

Страница 12: ...ur une installation sous une armoire à fond en retrait utiliser les lignes pour mesurer l épaisseur du décalage causé par le mur de l armoire et plier le gabarit en conséquence To be translated in Spanish P C CABINET FRONT C L A B VERTICAL EXHAUST A S A A V RTICAL EX 3 x 10 3 x 14 RECTANGULAR DUCTING 7 ROUND DUCTING OR Use this template for marking do not attempt to cut out the ducting hole throug...

Страница 13: ...crews Repeat for the other side frame 7 Install the proper installation brackets according to the type of cabinet framed or frameless See below 4 Drill a 1 8 dia pilot hole for house wiring at A location on template 5 Use a sharp pencil or 1 8 drill bit to mark the locations for the appropriate duct access holes 16 locations for 7 round duct or 4 corner locations for rectangular duct Remove the te...

Страница 14: ...on the outer edge of the bracket as shown Slide the bracket towards the center of cabinet and align the outside edge of the bracket with the marked line keeping the rear end edge leaning on the wall Use a pencil to mark 3 holes Remove the bracket Using a 7 64 drill bit drill 3 holes where marked Assemble the bracket to the cabinet bottom using a Phillips screwdriver and 3 provided countersunk wood...

Страница 15: ...the brackets and hang the hood using its 2 recessed FRONT HOLES C and D While holding the hood attach the power cable to the hood using the strain relief 5 Hang the hood on the brackets using the 2 recessed FRONT HOLES C and D While holding the hood run the house power cable into the hood through the strain relief previously installed in step 6 on page 10 Attach power cable to the hood HORIZONTAL ...

Страница 16: ...bag Insert 2 screws and washers per side in the slots as shown in inset on illustration below 8 For frameless cabinet secure the hood to the cabinet using 4 no 8 x 5 8 round head wood screws screws and washers included in parts bag Insert 2 screws and washers per side in the slots as shown in inset on illustration below FRAMED CABINET FRAMELESS CABINET WOOD SCREWS METAL SCREWS ...

Страница 17: ...TTOM CABINETS ONLY CABINET FRONT 3 4 1Ǫ 1 7 16 47 16 CABINET BOTTOM 12Ǭ 30 HOOD 15Ǭ 36 HOOD 18Ǭ 42 HOOD 12Ǭ 30 HOOD 15Ǭ 36 HOOD 18Ǭ 42 HOOD 3 X 10 VERTICAL DUCTING CABINET BOTTOM CABINET FRONT HORIZONTAL DUCT ACCESS HOLE HOOD MOUNTING SCREWS 4 ELECTRICAL ACCESS HOLE IN WALL 3Ǭ CENTER LINE WOOD SHIMS RECESSED BOTTOM CABINETS ONLY 13 16 3 16 5 5 12Ǭ 30 HOOD 15Ǭ 36 HOOD 18Ǭ 42 HOOD 12Ǭ 30 HOOD 15Ǭ 36...

Страница 18: ... back towards wall until mounting screw heads are engaged in narrow end of keyhole slots in top of hood While holding the hood tighten screws securely Attach power cable to the hood using the strain relief DUCTED INSTALLATION ONLY Install the Hood Standard installation 3 Connect ductwork to hood and use metal foil duct tape to make joints secure and air tight Make sure the damper assembly or round...

Страница 19: ...tandards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power from being switched on accidentally CAUTION Ensure both tabs on inner top of hood are engaged in their corresponding slots in wiring cover Also take care not to pinch wires while reinstalling wiring cover SCREW MOTOR GROUND WIRE HOUSE POWER CABLE GROUND SCREW 2 Reinstall wiring ...

Страница 20: ...clockwise until secure The BNSC1 Series range hoods require two shielded Halogen Bulbs 120 V 50 W max MR16 or PAR16 with GU10 base not included NOTE The Suction Cup Tool included with hood can be used to install and remove light bulbs Press suction cup tool on bulb and rotate counterclockwise to remove bulb or clockwise to install bulb SUCTION CUP TOOL WARNING Do not touch lamps during or soon aft...

Страница 21: ...K High W 120 V AC Line Neutral Ground G Y W BK O R FAN MOTOR BN BN W R BK LED LED W COLOR CODE BK BL BN BN W BLACK BLUE BROWN BROWN WHITE G Y O R W GREEN YELLOW ORANGE RED WHITE 1 2 3 4 5 6 BNDF1 SERIES G Y W BK O R FAN MOTOR BN BN W G Y R Low BK High W 120 V AC Line Neutral Ground BK BK Motor Switch Light Switch Y Low BL High W W BK BK COLOR CODE BK BL BN BLACK BLUE BROWN R W Y RED WHITE YELLOW B...

Страница 22: ...0433 CAPTOUCH CONTROL LED BLACK WITH SCREWS 1 1 S97020452 WIRE HARNESS 1 1 1 1 1 1 1 S97020360 PARTS BAG INCLUDING 4 METAL SCREWS NO 8 18 X 1 2 4 WASHERS 6 ROUND HEAD NO 8 X 5 8 WOOD SCREWS 6 NO 8 X 1 2 COUNTERSUNK WOOD SCREWS 1 1 1 1 1 1 1 S97020466 NON DUCTED FILTER TYPE XC SET OF 2 NON DUCTED INSTAL ONLY 1 1 1 S97020467 NON DUCTED FILTER TYPE XD SET OF 2 NON DUCTED INSTAL ONLY 1 1 1 S97020468 N...

Страница 23: ...VER PLATE BLACK INCLUDING SCREWS 1 1 S97020030 RECIRCULATION COVER PLATE WHITE INCLUDING SCREWS 1 1 S97020031 RECIRCULATION COVER PLATE STAINLESS STEEL INCLUDING SCREWS 1 1 2 SR680708 7 ROUND DUCT PLATE INCLUDING SCREWS 1 1 1 1 1 1 3 S97020534 3 X 10 DAMPER ASSEMBLY INCLUDING SCREWS 1 1 1 1 1 1 4 S97020408 BLOWER MOTOR INCLUDING 4 SCREWS AND 1 CAPACITOR 1 1 1 1 1 1 5 S97020407 FANPELLER INCLUDING ...

Страница 24: ...or replaced Product or replacement parts to you at no charge You are responsible for all costs for removal reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or part the Company is not responsible for damage i...

Отзывы: