#2 Chootoo Road, South Aranguez, San Juan, Trinidad
MODELS B5830SS • B5836SS
Page 6
INSTALL THE HOOD
(Non-Ducted Hoods Only)
NOTE: Non-ducted installations require Non-Duct Kit,
Model RK58 (purchase separately).
1. CAUTION: Do not use plastic or rigid metal duct.
2. Do not remove the protective plastic film covering the
decorative flue and the hood at this time.
3. Lay the back side of the hood flat on a table. Use a piece of
cardboard to avoid damaging the table or the hood.
4. Attach damper / duct connector to top of hood using (4) #8
x 3/8” Pan Head mounting screws.
5. Remove damper flaps from damper / duct connector and
discard flaps.
NON-DUCT KIT MODEL RK58 CONTENTS
8. Measure and install steel ductwork to hood duct connector.
Use duct tape to make all joints secure and air tight.
9. Hold hood up close to wall mounting location and plug
power cord into wall outlet.
10. Align the hood and center it above the hood mounting
bracket. Make sure ductwork on hood lines up and attaches
to ductwork in ceiling. Gently lower the hood until it securely
engages the bracket.
11. Use duct tape to make all joints secure and air tight.
INSIDE BACK OF HOOD
MOTOR/BLOWER
ASSEMBLY
HOLES
LOCATION
SIDE VIEW
Ø 5/16” TYP.
12. With the hood hanging in place, drill through both holes
located in the inside lower back of hood using a 5⁄16” drill
bit. Insert the included drywall anchors into the drilled holes
(one for each hole). Install (2) washers and (2) #8 x 1-1/2”
mounting screws through the hood back and into the drywall
anchors. Verify that the hood is centered and leveled. Tighten
all screws completely.
13. Reinstall grease filters by aligning rear filter tabs with slots
in the hood. Pull down the metal latch tab, push filter into
position and release. Make sure filters are securely engaged
after installation.
14. Slightly push aside the upper flue to avoid any damage while
installing the lower flue to the hood top using (2) #8 x 3/8”
screws through the lower flue side slots.
15. Slide the upper flue upward until it is aligned with its mounting
bracket. The bracket should be inside the flue. Secure the
upper flue to the upper flue mounting bracket using (2) #8 x
3/8” mounting screws.
16. Remove protective plastic film covering the upper flue and
the hood.
UPPER
FLUE
UPPER FLUE MOUNTING BRACKET
DUCT LENGTH
DECORATIVE
FLUE
6” ROUND
STEEL DUCT
NON-DUCT
PLENUM
2 TIE
WRAPS
FLEXIBLE DUCT
NON-DUCTED
RECIRCULATION
FILTERS
NON-DUCT PLENUM
COLLAR
8 MOUNTING
SCREWS
(ST4 x 8
Round Head)
MODELS B5830SS • B5836SS
Page 7
9. Attach
aluminum
flexible
duct to the
damper / duct
connector
with a tie
wrap.
10. Attach flexible
duct to non-
duct plenum
collar and
secure with
tie wrap. Tape
all joints with
duct tape.
NOTE: 10-ft. ceilings require 10-ft. Flue Extension Model
FXN58SS (purchase separately). Discard the upper flue
supplied with your hood and replace it with the Model
FXN58SS flue extension.
11. Remove the upper flue from inside the lower flue. Install the
lower flue bracket to the lower flue using (2) flue bracket
screws #8 x 3/8”, make sure that the slots are at the top.
Carefully replace the upper flue inside the lower flue.
Remove protective plastic film covering the lower flue only.
12. Carefully place both flues into the recessed area of hood
top. Slightly push aside the upper flue to avoid any damage
while installing the lower flue to the hood top by using (2) #8
x 3/8” screws through the lower flue side slots.
13. Attach non-duct plenum with collar to upper flue using (4)
ST4 x 8 round head screws.
14. Hold hood up close to wall mounting location and plug
power cord into wall outlet.
15. Align the hood and center it above the hood mounting bracket.
Gently lower the hood until it securely engages the bracket.
6. Remove the
grease filters
by pulling
down the
metal latch
tab and
tilting filters
downward to
remove.
7. Attach non-duct collar to non-duct plenum using (4) ST4 x
8 round head screws.
8. Measure distance “A”. This will be the length of the
extended flex duct.
LOWER FLUE MOUNTING BRACKET
LOWER
FLUE
16. With the hood hanging in place, drill through both holes
located in the inside lower back of hood using a 5⁄16” drill
bit. Insert the included drywall anchors into the drilled holes
(one for each hole). Install (2) washers and (2) #8 x 1-1/2”
mounting screws through the back of the hood and into
the drywall anchors. Verify that the hood is centered and
leveled. Tighten all screws completely.
17. Attach (2)
two non-duct
recirculation
filters to sides
of blower by
aligning key lock
slot and rotating
until filters lock
into place.
UPPER
FLUE
UPPER FLUE MOUNTING BRACKET
A
NON-DUCT PLENUM
6” ALUMINUM
FLEX DUCT
DAMPER / DUCT
CONNECTOR
3-5/8”
For replacement non-duct recirculation filters - purchase
S97018030 or ROUNDFILTER.
18. Reinstall grease filters by aligning rear filter tabs with
slots in the hood. Pull down the metal latch tab, push filter
into position and release. Make sure filters are securely
engaged after installation.
19. Slide up the upper flue upward until it is aligned with its mounting
bracket. The bracket should be inside the flue. Secure the
upper flue to the upper flue mounting bracket using (2) #8 x
3/8” mounting screws.
20. Remove protective plastic film covering the flue and the hood.
INSIDE BACK OF HOOD
MOTOR/BLOWER
ASSEMBLY
HOLES
LOCATION
SIDE VIEW
Ø 5/16” TYP.
MODELS B5830SS • B5836SS
Page 8
OPERATION
The hood is operated using the push buttons on the front panel.
Push the light button to turn the lights on and off.
Push the fan controls to select low, medium, or high blower
speed.
Push the OFF button to turn the blower off.
VQ0010
!
VQ0010
!
OFF
LOW
MED.
HIGH
LIGHT
FAN CONTROLS
ON/OFF
LIGHT BULBS
VQ0009
!
WARNING
Bulbs may be hot. Always allow bulbs to cool down before
removing them.
This range hood requires two halogen bulbs (Type JC, 12V, 20W
Max, G-4 Base).
To change bulbs:
1. Remove light bulb cover by gently pushing it upward and
turning it counterclockwise.
2. Replace bulb.
3. Re-install light bulb cover by gently pushing it upward and
turning it clockwise.
LIGHT BULB COVER
MAINTENANCE
Grease Filters
Grease filters should be cleaned monthly. Remove grease
filters by pulling down on the metal latch tab. This will
disengage the filter from the hood. Tilt the filter downward and
remove.
To clean all-metal filters: Use a warm detergent solution or
put them in the dishwasher using a non-phosphate detergent.
Discoloration of the filter may occur if using phosphate
detergent or as a result of local water conditions - but this will
not affect filter performance. This discoloration is not covered
by the warranty.
Non-Duct Recirculation Filters
Change the non-duct recirculation filters every 6 months.
Rotate the filters to remove them from the blower and replace.
Hood Cleaning
How to maintain the bright look of stainless steel and help
prevent corrosion.
Dos:
- Once a month, wash surfaces with clean cloth or rag soaked
with warm water and mild soap or liquid dish detergent.
- Always clean in the direction of original polish lines.
- Always rinse well with clear water (2 or 3 times) after
cleaning. Wipe dry completely.
- You may also use a specialized household stainless steel
cleaner.
Don’ts:
- Do not use any steel or stainless steel wool or any other
scrapers to remove stubborn dirt.
- Do not use any harsh or abrasive cleansers.
- Do not allow dirt to accumulate.
- Do not let plaster dust or any other construction residues
reach the hood. During construction or renovation, cover the
hood to make sure no dust sticks to stainless steel surface.
Avoid: when choosing a detergent
- Any cleaners that contain
bleach
will attack stainless steel.
- Any products containing :
chloride
,
fluoride
,
iodide
,
bromide
will deteriorate surfaces rapidly.
- Any
combustible products
used for cleaning such as
acetone
,
alcohol
,
ether
,
benzol
, etc., are highly explosive
and should never be used close to a range.
MODELS B5830SS • B5836SS
Page 9
SERVICE PARTS
WARRANTY
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of
original purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER
ACCESSORIES FOR DUCTING. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper
maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the
above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-
NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states
do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of
any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711
Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9 www.broan.ca 877-896-1119
99526964D
KEY PART NO.
DESCRIPTION
QTY.
1 S99526972 Decorative Upper and Lower Flues
1
2 S99526974 Motor / Blower Assembly
1
3 S99526975 Light Socket Assembly
2
4 S99527010 Light Trim Ring / Lens Assembly
2
5 S99526976 Push Button Assembly
1
6 S97018027 Aluminum Grease Filters (2 per hood) B5830SS 1
S97018028 Aluminum Grease Filters (3 per hood) B5836SS 1
7 S97018030 Non-Duct Recirculation Filters (pair)
1
8 S99526983 Damper / Duct Connector
1
9 S99526984 6” Dia. Expandable Flexible Aluminum Duct
1
10 S99526992 Non-Duct Plenum Assembly
1
11 S99526986 Hood Mounting Bracket
1
12 S99526988 Lower Flue Mounting Bracket
1
13 S99526990 Upper Flue Mounting Bracket
1
S99527011 Transformer (not shown)
1
S99527012 Capacitor (not shown)
1
S99527013 Plastic Cover (not shown)
1
S99526993 Parts Bag (not shown)
1
Order service parts by Part No. - not by Key No.
1
2
4
5
6
7
8
9
10
11
12
13
Replacement parts can be ordered on our website:
www.broan.com
WIRING DIAGRAM
3
TO MOTOR
HALOGEN LIGHTS
TRANSFORMER PCB
CAPACITOR
PUSHBUTTON
B
R
N
B
L
K
BLK
BLK
R
W
Y B
R
N
W G
R
Y
B
L
K
O
BLK
W
R
BRN
W
O
R
stop low mid high lamp
GRN
B
L
K BLU
W
GRN / YLW
BROAN - B58 SERIES - RANGE HOODS
INSTALLATION GUIDE