Appendix B 

(cont’d)

UNIT DIMENSIONS

B-3: B12LC (WITHOUT RECIRCULATION MODULE)

41.206"

40.326"

20.000"

5.715"

20.620"

14.250"

34.000"

5.125"

19.207"

4.028"

1

1.325"

12.000"

15.000"

20.000"

4.000"

2.750"

1

1

.000"

20.000"

9.878"

24.500"

8.000"

8.000"

4.000"

8.000"

10.000"

B

A

FRESH AIR

T

O

 B

UILDING

EXHA

UST

 AIR

T

O

 OUTDOORS

LINE PO

WER

LO

W V

O

L

T

A

G

E

TERMINAL

 STRIPS

CONTR

OL

 BO

X

A

CCESS

CONTR

OL

 CO

VER

A

CCESS DOOR

CORE

REVERSED DOOR OPTION

A

CCESS DOOR

DRAIN FITTING

EXHA

UST

 AIR

FR

OM B

U

ILDING

FRESH AIR

FR

OM OUTDOORS

STRAP

 MOUNT

LOCA

TION

REVERSE DOOR

OPTION

C

D

B

A

TO

P

OUTDOOR AIR

RETURN AIR

NO

TE:

 FOR UNITS 

WITH 

THE REVERSED DOOR OPTION,

INTERIOR 

COMPONENTS 

WILL

 APPEAR AS A

 MIRR

OR

IMA

GE OF 

THE 

ABO

VE DIA

GRAM.

A

 MINIMUM OF 12.000" CLEARANCE FR

OM 

ANY

 OBSTR

UCTION

IS REQ

UIRED FOR REMO

V

A

L

 OF CONTR

OL

 BO

X.

A

 MINIMUM OF 15.000" CLEARANCE FR

OM 

ANY

 OBSTR

UCTION IS REQ

UIRED FOR REMO

V

AL

OF HEA

T

 RECO

VER

Y

 CORES

, F

ANS

, ETC

.

THE 

A

CCESS DOOR CAN BE REMO

VED FR

OM CABINET

 WITH ONL

Y

 2.000" OF CLEARANCE.

EXHA

UST

 AIR

SUPPL

Y

 AIR

FR

ONT

 VIEW

RIGHT

 SIDE

LEFT

 SIDE

Center of g

ra

vity

Direction of airflo

w

NO

TES:

PTS

B12LC POL

Y

 CORE

 B12LC ALUMINUM CORE

LB

.

54.02

38.98

54.02

38.98

186.00

Kg

24.50

17.68

24.50

17.68

84.36

PTS

A

B

C

D

TO

T

A

L

LB

.

60.41

43.59

60.41

43.59

208.00

27.40

19.77

27.40

19.77

94.34

Kg

A

B

C

TO

T

A

L

D

14 GA

UGE 

WIRE NUT

CONDENSA

T

E DRAIN FITTING (2X)

A

B

3/4" NPT

CONNECTION T

ABLE

CONNECTION SIZES

NO

TE:

 THIS MODEL

 HAS 

A

 D

AMPER LOCA

TED ON 

THE OUTDOOR INT

AKE CONNECTION.

 THIS D

AMPER 

WILL

 CLOSE DURING 

A

 DEFR

OST

 CYCLE OR 

WHEN 

THE UN

IT

 IS PLA

CED IN 

THE 'OFF' POSITION 

WITH PO

WER MAINT

A

INED 

T

O

 THE UNIT

.

            

THIS D

AMPER IS NO

T

 DESIGNED 

AS 

A

 BA

CKDRAFT

 D

AMPER 

AND 

WILL

 REMAIN OPEN IF PO

WER IS DISCONNECTED FR

OM 

THE UNIT

 FOR 

A

NY

 REASON.

VK0110A

 B12LC ER

V HM CORE

PTS

LB

.

Kg

A

B

C

D

TO

T

A

L

57.84

41.68

57.92

41.68

199.00

26.84

19.35

26.88

19.34

92.41

Содержание B12LC

Страница 1: ...Heat Recovery Ventilators and Energy Recovery Ventilators Installation Operation and Service Instructions INSTALLER READ THESE INSTRUCTIONS AND LEAVE THIS MANUAL TO THE END USER VB0002 VB0001 22638 r...

Страница 2: ...6 4 Airflow Measurements and Balancing 7 5 Maintenance 7 8 5 1 Bi Monthly Maintenance 7 5 2 Annual Maintenance 8 6 Service 8 9 6 1 Parts Replacement 8 9 6 2 Troubleshooting 9 7 Service Parts 10 11 7 1...

Страница 3: ...unit OFF during construction or renovation Do not use the unit when sanding drywall Certain types of dust and vapors may damage the system 2 Please read specification label on product for further info...

Страница 4: ...cal building codes regarding the use of rubber straps in commercial buildings Attach the straps to the unit with two no 8 screws provided Then attach the other end of the strap to the ceiling joists t...

Страница 5: ...the use smooth radius elbows or square elbows with turning vanes to achieve maximum performance 2 6 Exterior Hoods It is important that the fresh air intake hood be positioned well away from any sourc...

Страница 6: ...st damper opens recirculation opening Power connected FF control contacts close during unit ventilation or defrost cycle 3 3 Defrost The unit functions are controlled by integrated controls in the uni...

Страница 7: ...a soft cloth and mild cleaning solution Also ensure that the drain fittings are free from dirt and are draining freely WARNING Risk of electric shocks Before performing maintenance always stop the un...

Страница 8: ...ld soap Rinse under a heavy stream of water For ERV HM core use a vacuum cleaner or low pressure air jet It is not recommended to use solvents or detergents as these may damage the media or structure...

Страница 9: ...CAUSES SOLUTIONS Inside air is too dry Over ventilation speed setting too high Dehumidistat setting is too low Adjust speed setting Set dehumidistat control in a higher position if applicable Persist...

Страница 10: ...2 Optional MERV8 Filter for B6LC B2LC unitary Ref Part No Description L SV1808130 PCB Electronic B6LC B12LC SV202382 Thermistor B6LC B12LC SV500025914 Relay SPDT 120 VAC 1 HP 30 A 120 VAC B6LC B12LC S...

Страница 11: ...ter Optional MERV 8 B6LC B12LC unitary Ref Part No Description K SV1808130 PCB Electronic B6LC B12LC SV202382 Thermistor B6LC B12LC SV500025914 Relay SPDT 120 VAC 1 HP 30 A 120 VAC B6LC B12LC SV500025...

Страница 12: ...r Rubber Vibration Isolator Supplied by others U Channel Supplied by others 3 8 10mm Threaded Rod Supplied by others NOTE Diagrams show standard unit configuration For units with the reversed door opt...

Страница 13: ...TION IS REQUIRED FOR REMOVAL OF HEAT RECOVERY CORES FANS ETC THE ACCESS DOOR CAN BE REMOVED FROM CABINET WITH ONLY 2 000 OF CLEARANCE CONTROL PLATE ACCESS DOOR CORE REVERSED DOOR OPTION Center of grav...

Страница 14: ...53 12 00 15 00 Access Door Core Reversed Door Option Control Plate A minimum of 12 00 clearance from any obstruction is required for removal of control box A minimum of 15 00 clearance from any obstr...

Страница 15: ...NCE FROM ANY OBSTRUCTION IS REQUIRED FOR REMOVAL OF HEAT RECOVERY CORES FANS ETC THE ACCESS DOOR CAN BE REMOVED FROM CABINET WITH ONLY 2 000 OF CLEARANCE EXHAUST AIR SUPPLY AIR FRONT VIEW RIGHT SIDE L...

Страница 16: ...of the above diagram A minimum of 12 00 clearance from any obstruction is required for removal of control box A minimum of 15 00 clearance from any obstruction is required for removal of heat recovery...

Страница 17: ...aft Damper for recirculation defrost option only Min 12 305 mm Exhaust Air to Outdoors Fresh Air to Building Appendix D DRAIN CONNECTIONS Min 3 76 mm Min 1 25 mm 3 4 NPT coupler Water trap Min 4 102 m...

Страница 18: ...r electronic control within the unit to control ventilation sequences This wall control requires a 4 wire connection to the unit as shown below Without the wall control fans can be operated with a rem...

Страница 19: ...ER 24 VAC 24 VAC WALL CONTROL COMMANDE MURALE NOTE Use of 24 VAC circuit requires isolating contacts ex thermostat to prevent interconnection of Class 2 outputs Black Noir ON OFF MARCHE ARR T LOW BASS...

Страница 20: ...building The tables below gives the heating requirements at different temperatures and airfl ows NOTE The data does not refl ect a reduction in effectiveness due to frosting Based on the standard air...

Страница 21: ...N POSITION SETTING 10K Defrost Thermistor Main Electrical Enclosure UCB1 B6LC B12LC Exhaust Defrost Normal Low Speed stop GREEN YELLOW LOW COM HIGH BLACK RED OCC UNOCC REM FAN INTERLOC 9 8 7 6 5 4 3 2...

Страница 22: ...L WH R WH Y Y BLACK BLACK RED BLACK YELLOW BLUE BROWN GREEN GREEN YELLOW ORANGE RED WHITE WHITE BLUE WHITE RED WHITE YELLOW YELLOW WIRING COLOR CODE BN BN BN BN 5 6 4 2 3 1 LOGIC DIAGRAM VE0469A Ref 1...

Страница 23: ...e UCB1 SYSTEM DIAGRAM ITEM C JU1 OFF B OFF A OFF D ON E ON F ON G ON POSITION SETTING From To J3 9 J3 1 J3 8 J3 9 J3 6 J3 7 J3 8 J3 8 J3 2 J3 8 J3 9 GREEN YELLOW LOW COM HIGH BLACK RED OCC UNOCC REM F...

Страница 24: ...K BK R BK Y BL BN G G Y O R WH WH BL WH R WH Y Y BLACK BLACK RED BLACK YELLOW BLUE BROWN GREEN GREEN YELLOW ORANGE RED WHITE WHITE BLUE WHITE RED WHITE YELLOW YELLOW WIRING COLOR CODE LOGIC DIAGRAM BN...

Отзывы: