Page 3
MODEL 741SN
SWITCH BOX
LIGHT
FAN
DUAL CONTROL
(purchase separately)
WHITE
BLACK
RED
GROUND
(bare)
WIRING
PLATE
120 VAC
LINE IN
BLUE
BLACK
RECEPTACLE
(FAN)
WHITE
RECEPTACLE
(LIGHT)
INSTALL THE HOUSING
(continued)
ATTACH THE GRILLE PAN AND
GLASS SHADE
INSTALL THE DUCTWORK
FLUSH
NOTE:
The duct connector has a counter-
balanced damper flap. The flap will be
“open” approx. 1” when duct connector is
attached to housing. This design permits
insulation to be in direct contact with
fan/light housing per UL (Underwriters
Laboratories) standards. The slightest
backdraft, however, will close the damper
flap, preventing air from entering unit or
finished space.
CONNECT THE WIRING
1. Snap the damper/duct connector onto housing. Make sure
that tabs on the connector lock into slots in housing. Top of
damper/duct connector should be flush with top of housing.
NOTE:
Make sure damper flap is in place inside of duct
connector. If it is not:
Squeeze top and bottom of connector
to
snap flap back into place.
4. Place housing in opening so that its bottom edge is flush
with finished ceiling. Nail to joist through keyhole on both
sides. To ensure a noise-free installation, drive another nail
through the top hole of each mounting bracket.
Existing Construction
5. Additional mounting holes are provided for installations
where access from above is inconvenient or not possible.
Nail or screw housing directly to joists or framing.
ADDITIONAL
MOUNTING
HOLES
1. Locate the grille pan over
the fan housing and con-
nect the wiring harness
plug into white receptacle
in the fan housing.
2. Insert rod through center
hole of grille pan. Use
washer between collar
on rod and pan.
3. Thread rod onto grille
screw in housing, until
pan is tight against ceil-
ing.
4. Install bulbs. (see “Bulb
Replacement” chart on
next page for proper
bulbs for your model).
5. Place glass shade over
mounting rod and align
shade onto grille pan.
Secure glass shade to
grille pan with finial cap
and finial nut as shown.
6. Restore electrical power
and check operation of
the unit.
1. Wire unit following diagram above. Run electrical cable as
direct as possible to unit. Do not allow cable to touch sides
or top of unit after installation is complete.
GRILLE
SCREW
GRILLE
PAN
ROD
COLLAR
WASHER
2. Connect 4” round duct to damper/duct connector and
extend duct to outside through a roof or wall cap. Check
damper to make sure that it opens freely. Tape all duct
connections to make them secure and air tight.