background image

INSTALLATION

8.  For best results, choose a location which allows fan to be vented 

outside with the shortest possible duct run and the fewest num-

ber of elbows.

9.  Position unit between joists and extend mounting brackets.  

Position brackets such that the bottom edge of housing will be 

flush with finished ceiling.  Mark the top of keyhole slot on all 

four mounting brackets.

10.  Remove unit temporarily, and pound nails partially into joists at 

all four marked locations.

EMBOSSED 

MEASURING 

GUIDES

FLUSH

11.  Hang unit from nails and use embossed measuring guides to 

check if unit will be flush with finished ceiling.  Pound nails tight.  

For wide joist centers:  A #8 x 3/8 self-tapping screw can be used 

to join extended brackets together and create a rigid mount.  To 

ensure a noise-free mount, crimp the bracket channels tightly 

around mounting brackets.

12.  Snap the damper/duct connector onto housing.  Make sure that 

tabs on the connector lock in housing slots. (Top of damper/duct 

connector will be flush with top of housing.)

NOTE

WIRE 

OPENING

RELEASE SLOT

If the switch has not been wired properly and wires need to be 

moved:
1.  Each wire opening has a release slot.
2.  Push a small nail or screwdriver into release slot while gently 

removing wire.

3.  DO NOT pull any wire out of the switch without using the release 

slot. The switch may be damage

d.

2

WARNING: To reduce the risk of fire, do not store or use gaso-

line or other flammable vapors and liquids in the vicinity of 

the heater.

CAUTION: High temperature, risk of fire, keep electrical cords, 

drapery, furnishings, and other combustibles at least 3 feet (0.9 

m) from the front of the heater and away from the side and rear.

Содержание 655C

Страница 1: ...t least 3 feet 0 9 m from the front of the heater 6 Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended 7 Do not operate any heater after it malfunctions Disconnect power at service panel and have heater inspected by a reputable electrician before reusing 8 Do not use outdoors 9 To disconnect heater turn cont...

Страница 2: ... and create a rigid mount To ensure a noise free mount crimp the bracket channels tightly around mounting brackets 12 Snap the damper duct connector onto housing Make sure that tabs on the connector lock in housing slots Top of damper duct connector will be flush with top of housing NOTE WIRE OPENING RELEASE SLOT If the switch has not been wired properly and wires need to be moved 1 Each wire open...

Страница 3: ...overheating and or fire the grille must be installed as shown Acorn nut must attach to threaded rod through proper hole in light reflector 16 Slide the light reflector into opening in grille and plug into WHITE receptacle Use acorn nut from plastic bag to attach grille re flector assembly to threaded rod on housing Tighten securely using pliers or nut driver Install a light bulb 100 Watt maximum 1...

Страница 4: ...Before using heater make sure heater has been properly installed according to installation steps beginning with the PREPARATION section on page 1 4 OPERATION ...

Страница 5: ...y depressing sides and pull down Use bulb rated up to 100 watts only LUBRICATION The heater is permanently lubricated and never needs oiling or disassembly CLEANING Clean heater once a month as follows 1 Turn off power at service panel 2 Make sure heating element is cool 3 Use a soft brush attachment to gently vacuum grille openings or wipe grille clean with a soft cloth 4 Restore power CAUTION ME...

Страница 6: ... A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence ac...

Отзывы: