INSTALLATION
8. For best results, choose a location which allows fan to be vented
outside with the shortest possible duct run and the fewest num-
ber of elbows.
9. Position unit between joists and extend mounting brackets.
Position brackets such that the bottom edge of housing will be
flush with finished ceiling. Mark the top of keyhole slot on all
four mounting brackets.
10. Remove unit temporarily, and pound nails partially into joists at
all four marked locations.
EMBOSSED
MEASURING
GUIDES
FLUSH
11. Hang unit from nails and use embossed measuring guides to
check if unit will be flush with finished ceiling. Pound nails tight.
For wide joist centers: A #8 x 3/8 self-tapping screw can be used
to join extended brackets together and create a rigid mount. To
ensure a noise-free mount, crimp the bracket channels tightly
around mounting brackets.
12. Snap the damper/duct connector onto housing. Make sure that
tabs on the connector lock in housing slots. (Top of damper/duct
connector will be flush with top of housing.)
NOTE
WIRE
OPENING
RELEASE SLOT
If the switch has not been wired properly and wires need to be
moved:
1. Each wire opening has a release slot.
2. Push a small nail or screwdriver into release slot while gently
removing wire.
3. DO NOT pull any wire out of the switch without using the release
slot. The switch may be damage
d.
2
WARNING: To reduce the risk of fire, do not store or use gaso-
line or other flammable vapors and liquids in the vicinity of
the heater.
CAUTION: High temperature, risk of fire, keep electrical cords,
drapery, furnishings, and other combustibles at least 3 feet (0.9
m) from the front of the heater and away from the side and rear.