background image

MODEL 655C

READ AND SAVE THESE INSTRUCTIONS

PREPARATION

1.  Make sure the heater 

assembly is unplugged 

from the RED receptacle.

2.  Loosen the two retain-

ing screws on the inside 

of the heater discharge 

opening. Place a screw-

driver tip between the 

outer wall of the dis-

charge opening and the 

fan housing.  Gently pry 

outward until the exhaust 

discharge slips off the 

support lip on the outer 

housing.

3.  Unhook hinge pins and 

lift heater assembly out 

of housing.

4.  Unplug the fan assembly 

from the BLACK recepta-

cle.  Remove the plastic 

bag and set it aside.

5.  Remove the mounting 

screw and carefully lift 

the fan assembly out of 

the housing.

HINGE PIN

RETAINING 

SCREWS

1

IMPORTANT INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE 

INSTALLING OR USING THIS  HEATER.

To reduce the risk of fire, electric shock, or injury to persons, observe 

the following:

1.  Use this unit only in the manner intended by the manufacturer. If 

you have questions, contact the manufacturer at the address or 

telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service panel 

and lock the service disconnecting means to prevent power from 

being switched on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prominent warning 

device, such as a tag, to the service panel.

3.  Installation work and electrical wiring must be done by a qualified 

person(s) in accordance with all applicable codes and standards, 

including fire-rated construction codes and standards.

4.  When cutting or drilling into wall or ceiling, do not damage electrical 

wiring and other hidden utilities.

5.  This heater is hot when in use. To avoid burns, do not let bare skin 

touch hot surfaces. Keep combustible materials, such as furniture, 

pillows, bedding, papers, clothes, etc. and curtains at least 3 feet 

(0.9 m) from the front of the heater.

6.  Extreme caution is necessary when any heater is used by or near 

children or invalids and whenever the heater is left operating and 

unattended.

7.  Do not operate any heater after it malfunctions. Disconnect power at 

service panel and have heater inspected by a reputable electrician 

before reusing.

8.  Do not use outdoors.

9.  To disconnect heater, turn controls to off, and turn off power to heater 

circuit at main disconnect panel (or operate internal disconnect 

switch, if provided).

10. Do not insert or allow foreign objects to enter any ventilation or 

exhaust opening, as this may cause an electric shock or fire, or 

damage the heater.

11.  To prevent a possible fire, do not block air intakes or exhaust in any 

manner.

12. A heater has hot and arcing or sparking parts inside. Do not use it in 

areas where gasoline, paint, or flammable vapors or liquids are used 

or stored.

13. Use this heater only as described in this manual. Any other use not 

recommended by the manufacturer may cause fire, electric shock, 

or injury to persons.

14. This product must be grounded.

15. Do not install heater in a tub or shower enclosure.

16. This product is designed for ceiling installation only. This product 

is designed for installation in ceilings up to a12/12 pitch. Ductwork 

must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.

17.  Install heater at least 6 inches from floor or any adjacent wall.

18. Do not connect heater to dimmer switch or speed control.

19. Provide a separate 20 AMP circuit.  Use 12 GA. power cable of type 

which meets code.

20. For greatest efficiency, install heater so heat is directed toward tub 

or shower area.  Avoid directing toward walls or windows.

SAVE THESE INSTRUCTIONS

6.  Refer to the wiring diagram of your unit on the next page.  Re-

move appropriate knockout(s) by inserting a screwdriver blade 

into slots and bending it back and forth to break tabs.

KNOCKOUTS

7.  Insert the adjustable mounting brackets into the bracket chan-

nels on the housing.

Содержание 655C

Страница 1: ...t least 3 feet 0 9 m from the front of the heater 6 Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended 7 Do not operate any heater after it malfunctions Disconnect power at service panel and have heater inspected by a reputable electrician before reusing 8 Do not use outdoors 9 To disconnect heater turn cont...

Страница 2: ... and create a rigid mount To ensure a noise free mount crimp the bracket channels tightly around mounting brackets 12 Snap the damper duct connector onto housing Make sure that tabs on the connector lock in housing slots Top of damper duct connector will be flush with top of housing NOTE WIRE OPENING RELEASE SLOT If the switch has not been wired properly and wires need to be moved 1 Each wire open...

Страница 3: ...overheating and or fire the grille must be installed as shown Acorn nut must attach to threaded rod through proper hole in light reflector 16 Slide the light reflector into opening in grille and plug into WHITE receptacle Use acorn nut from plastic bag to attach grille re flector assembly to threaded rod on housing Tighten securely using pliers or nut driver Install a light bulb 100 Watt maximum 1...

Страница 4: ...Before using heater make sure heater has been properly installed according to installation steps beginning with the PREPARATION section on page 1 4 OPERATION ...

Страница 5: ...y depressing sides and pull down Use bulb rated up to 100 watts only LUBRICATION The heater is permanently lubricated and never needs oiling or disassembly CLEANING Clean heater once a month as follows 1 Turn off power at service panel 2 Make sure heating element is cool 3 Use a soft brush attachment to gently vacuum grille openings or wipe grille clean with a soft cloth 4 Restore power CAUTION ME...

Страница 6: ... A PARTICULAR PURPOSE During this one year period Broan NuTone will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or parts which have been subject to misuse negligence ac...