WIRING
BOX
WHITE
GROUND
BLACK
120/127 VAC
POWER CABLE
TAPE HERE
ATTACH GRILLE
1. Attach power cable to electrical wiring box and switch box using
the proper connector for the type of cable being used.
2. Make electrical connections. Connect black to black, white to
white and bare or green wire to electrical wiring box using the
green ground screw.
CONNECT THE DUCT
(FOR WALLS 6" TO 10" THICK ONLY - INCLUDING INSIDE AND OUTSIDE
WALL COVERINGS)
1. Stretch the adjustable duct, slide it over the housing and tape it
in place. (You may need to shorten non-tapered end of flexible
duct to fit.)
INSTALL VENTILATOR IN WALL
1. Place ventilator into wall opening. Re-install electrical wiring box
and cover. Plug motor into receptacle in wiring box cover.
2. Fasten ventilator to inside wall with appropriate screws.
1. From outside, slip adjustable duct into wall cap and tape the joint.
2. Compress the excess duct back into the opening by positioning the
wall cap against the outside wall.
3. Fasten wall cap to outside wall and caulk around the edges.
ON/OFF
SWITCH
TAPE HERE
ATTACH WALL CAP
(FOLLOW STEPS 1 & 2 ONLY IF ADJUSTABLE DUCT IS USED)
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in
materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO OTHER WARRAN-
TIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is
found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover
(a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident,
improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended
installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do
not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PUR-
CHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE FOR
INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE
OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the
above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty
supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the
model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting
warranty service, you must present evidence of the original purchase date.
Broan-NuTone LLC Hartford, Wisconsin www.broan-nutone.com 800-558-1711
1 99110454 Grille
2
99260428
#6-32 Sheet Metal Nut (2 req.)*
3
99170245
#8B x 3/8 Sheet Metal Screw (3 req.)*
4
97005322
Motor Mounting Bracket 97005322
5
99080199
Motor (512M)
6 99020125 Blade
7
98004932
Wiring Box Cover
8
99150471
#10-32 x 1/2 Green Ground Screw*
9
98005329
Wiring Box
10 97011741
Housing
11 99270982 Receptacle
12
99610012
Adjustable Duct
13
97011740
Wall Cap
DESCRIPTION
NO.
PART
KEY
NO.
1. Spin grille onto its mounting screw until
the grille is tight against the wall.
2. Turn on the power and check for proper
operation of ventilator.
13
1
2
3
6
7
9
8
3
12
10
11
* Standard Hardware - May be purchased locally.
Always order replacement parts by “PART NO." - NOT by “KEY NO.”
5
4
WIRE THE VENTILATOR
WARNING:
SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE
PANEL BEFORE MAKING ELECTRICAL CONNECTIONS.
USE AND CARE
WARNING: SWITCH OFF POWER AT SERVICE PANEL AND LOCK
SERVICE PANEL BEFORE CLEANING OR SERVICING THIS VENTILATOR.
TO CLEAN FAN ASSEMBLY:
Unplug motor from black receptacle. Remove the motor assembly by
loosening the mounting screws and rotating the motor assembly clockwise.
Gently vacuum motor assembly and inside of housing.
METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED
IN WATER.
PERIODICALLY CHECK THE OUTER LOUVER FOR ACCUMULATED
DUST, LINT, ETC., WHICH MAY INTERFERE WITH PROPERLOUVER
CLOSURE.
WARNING: DO NOT SPRAY WATER INTO LOUVER-DAMAGE TO THE
FAN COULD OCCUR AND WATER COULD ENTER HOUSE.
MOTOR LUBRICATION
The motor is permanently lubricated. Do not oil or disassemble motor.
If the fan makes excessive noise or if there is unusual noise or smells of
smoke, disconnect power supply and contact customer service.
SERVICE PARTS
Model 512M
99043228D