background image

Содержание 43000 Series

Страница 1: ...or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FiRE DEPARTMENT 2 NEVER PICK UP A FLAMING PAN You may be burned 3 DO NOT USE WATER including wet dishcloths or towels a violent steam explosion will result 4 Use an extinguisher ONLY if A You know you have a Class ABC extinguisher and you already know how to operate it B...

Страница 2: ...OUND DUCT VENTING 3 I 4 x IO RECTANGULAR VENTING Ducting directly through the wall for range hoods mounted on an exterior wall Shown are two ways to duct through an outside wall If a wall cap is used directly off the back of the hood special care must be taken to make sure that the damper in the damper duct connector on the hood and damper in the wall cap do not interfere with each other when the ...

Страница 3: ...ize used so that duct will line up easily with damper duct connector on hood Install casing strips if cap will be installed on siding Attach required amount of duct to wall cap and run duct back to hood Fasten cap to wall and caulk well Make sure that enough duct runs into the room so that the duct will overlap the damper duct connector when the hood is installed Roof Cap Discharge Cut a hole in r...

Страница 4: ...ng burned REPLACEMENT PARTS 6 7 3 Key No Part No 1 97016971 97016972 97016970 97016973 2 97016971 97016972 97016970 97016973 3 R730088 4 R610045 R610050 R610051 5 R566088 6 99091020 99091021 99091022 99091027 7 R6689601 R6689602 R6689604 R6689605 Description FanSwitch White IncludesLightSwitch FanSwitch Almond IncludesLightSwitch FanSwitch Black IncludesLiqhtSwitch FanSwitch Biscuit IncludesDghtSw...

Страница 5: ...on una tapa ajustada o charola de metal despu6s apague la hornilla TENGA CUIDADO A FIN DE EVlTAR QUEMADURAS Si las llamas no se apagan de inmediato EVACUE Y AVlSE A LOS BOMBEROS 2 NO LEVANTE NUNCA UNA SARTEN QUE ESTEEN LLAMAS Usted se podr_ quemar 3 NO UTILICE AGUA incluyendo toallas de cocina mojadas puede resultar una explosi6n de vapor violenta 4 Utilice un extinguidor SOLAMENTE si A Usted sabe...

Страница 6: ... 10 8 3 X 25 4 cm REGISTRO _ tNCLUIDO SAQUE LA COM PANA ALETA DEL REGISTRO ESTORBA AL REGISTRO DEL TAPAPARED VENTIACION DE DUCTO VENTEACION RECTANGULAR DE REDONDO DE 7 17 8 cm 31 4 X 10 8 3 X 25 4 cm Et ducto directo a traves de la pared para campanas de cocina montadas en una pared exterior Se muestran dos maneras de instalar et ducto a traves de una pared exterior Si se usa un tapapared directam...

Страница 7: ...opiadas que se dan abajo parael tipode ducto que va a instalar Descarga por laTapapared Use una sierrade sableo de calar paracortar unagujero ligeramente mas grande que et tamaSo del ducto empleado a fin de que elducto quede bien alineado con et conector de registro ducto de ta campana Instaletiras contramarco si latapa va a instalarse en tas tablas de ta pared Conecte ta Iongitudrequerida de duct...

Страница 8: ...la Lasllamasprovocadasperlagrasatambiensepuedenapagarcon bicarbonate de sodio o un extinguidorquimico Apaguelas hornillas sipuedehacerlosin quemarse LISTADE REPUESTO 6 7 Clave NO Pieza NO Descripci6n 1 97016971 Interruptorde Ventilador Blanco incluye interruptorde la luz 97016972 Interruptorde Ventilador Almendra incluyeinterruptorde la luz 97016970 Interruptorde Ventilador Negro incluye interrupt...

Отзывы: