background image

Page 1

MODEL 345

WARNING  

  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have any questions, contact the manufacturer at the 
address or telephone number listed in the warranty.

2. Before servicing or cleaning unit, switch power off at 

service panel and lock the service disconnecting means to 
prevent power from being switched on accidentally. When the 
service disconnecting means cannot be locked, securely 
fasten a prominent warning device, such as a tag, to the 
service panel.

3. Installation work and electrical wiring must be done by a 

qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction codes and 
standards.

4. Sufficient air is needed for proper combustion and 

exhausting of gases through the flue (chimney) of fuel burning 
equipment to prevent backdrafting. Follow the heating 
equipment manufacturer’s guideline and safety standards such 
as those published by the National Fire Protection Association 
(NFPA), and the American Society for Heating, Refrigeration 
and Air Conditioning Engineers (ASHRAE), and the local code 
authorities.

5. When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.  The wiring must be permanent. DO NOT USE AN EXTENSION 

CORD! Use 14 GA. MINIMUM copper wire. Although the 
Powered Attic Ventilator may be wired directly to power, we 
advise that some type of shut off switch be installed in the 
line. Please see the section on electrical wiring for suggested 
wiring diagrams and instructions.

7.  To reduce the risk of electric shock, do not use this fan with 

any solid-state speed control device.

8.  This unit must be grounded.

9.  When applicable local regulations comprise more restrictive 

installation and/or certification requirements, the aforementioned 
requirements prevail on those of this document and the installer 
agrees to conform to these at his own expenses.

10. When performing installation, servicing or cleaning this unit, it 

is recommended to wear safety glasses and gloves.

MODEL 345 ROOF-MOUNT
POWERED ATTIC VENTILATOR

READ AND SAVE THESE INSTRUCTIONS

Installer: Leave this manual with the homeowner.

Register your product 

online at www.broan.ca

CAUTION  

!

1.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.  To avoid motor bearing damage and noisy and/or unbalanced 

impeller, keep drywall spray, construction dust, etc. off power 
unit.

3. This unit has an unguard impeller. Do not use in locations 

readily accessible to people or animals.

4. Fan is equipped with a thermostat which may start fan 

automatically. To reduce risk of injury or electric shock while 
servicing or cleaning unit, switch power off at service panel 
and lock service panel to prevent power from being switched 
on accidentally. When the service disconnecting means cannot 
be locked, securely fasten a prominent warning device, such 
as a tag, to the service panel.

5.  Home Ventilating Institute (HVI) recommends one square foot of 

open air inlet per 300 cfm of fan capacity. The best location for 
these air intake vents are under the eaves with direct access 
to the attic. Failure to provide these intakes could cause naturaldraft 
gas appliances to backdraft.

6.  Your attic fan installation will create a screened opening into 

your attic space. During a heavy rain storm there could be a light 
spray of rain into this attic space. This is a normal condition with 
all attic ventilators and will not cause any damage to the structure. 
We recommend that you do not store any valuable articles 
directly under the fan opening in the roof. During extreme rain 
and wind storms you may want to turn on your attic ventilator 
to prevent excess moisture accumulation in your attic.

7.  Records show, under ideal conditions, exposed galvanized steel 

can remain rust free up to 100 years. For best protection, the 
exposed portion of the roof sheet should be painted, especially 
in areas of unusually high industrial air pollution. Follow paint 
manufacturer’s instructions for good adhesion.

8.  This ventilator is intended for roof installation. 

9.  The dome may be painted with a high-quality paint. Follow the 

paint manufacturer’s recommendations for powder-coated steel.

10. Please read specification label on product for further information 

and requirements.

TOOLS AND MATERIAL REQUIRED

 

Slotted Screwdriver 

 

Sabre Saw or Keyhole Saw 

 

Pencil 

 

Roofing Cement

 

Drill 

 

Utility Knife or Shears (to cut shingles) 

 

Hammer 

 

Galvanized Roofing Nails (1¾” min)

 

1/4” Drill Bit 

 

Pry Bar (to remove roofing nails) 

 

Measuring tape 

 

Electrical Supplies (to comply with codes)

Содержание 345

Страница 1: ...the homeowner Register your product online at www broan ca CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impeller keep drywall spray construction dust etc off power unit 3 This unit has an unguard impeller Do not use in locations readily accessible to people or animals 4 Fan i...

Страница 2: ...tic measure and place a mark at the point which is one half the distance between 2 rafters closest to the position of the powered attic ventilator Draw a line parralel to the rafters Measure down from the roof peak the distance found in Step 1 and mark that measurement on the center line between the 2 rafters 3 Drill a guide hole through the roof at this mark 17 14 3 8 4 Cut out the red and blue t...

Страница 3: ... a pry bar remove nails holding shingles down from top two thirds of the 23 square drawn on the roof 9 Cut out the roof board s inside of the line Do not cut rafters INSTALLATION CONTINUED INSTALLATION CONTINUED 11 Slide the flashing under the shingles Start two thirds of the way down from the top of the 23 square Do not bend the shingles any more than necessary Center the ventilator over the hole...

Страница 4: ...RANCEBEFOREWIRING INSTALLATIONWORK AND ELECTRICALWIRING MUST BE DONE BY A QUALIFIED PERSON S IN ACCORDANCE WITH ALL APPLICABLE CODES AND STANDARDS INCLUDING THE NATIONAL ELECTRICAL CODE 1 Remove the thermostat wiring box cover plate Bring the power cable at least 6 into the ventilator wiring box Fasten to box with appropriate connector MOTOR VENTILATOR WIRING BOX MASTER ON OFF SWITCH BLK GRD WHT B...

Страница 5: ...e thermostat to turn the ventilator ON or OFF manually 3 Replace the metal cover plate over the thermostat wiring box and fasten securely 4 The thermostat setting determines the temperature at wich the ventilator turns on The ventilator automatically turns off when the attic temperature is 8 C 10 F lower than the thermostat setting The thermostat is factory set at 35 C 95 F for optimum operating e...

Страница 6: ...ated to it s original position on the motor mounting bracket The fan blade must also be relocated to it s original position on the motor shaft MAINTENANCE CONTINUED SERVICING FROM THE ATTIC SIDE 1 Remove three screws 1 4 bolts 9 holding the motor assembly to the roof plate 5 2 Motor assembly will drop down as the three bolts are removed TAKE CARE NOT TO BEND THE FAN BLADES 3 Lubricate top and bott...

Страница 7: ...utilisez pas pour évacuer des vapeurs ou des matières dangereuses ou explosives 2 Afin d éviter tout dommage au roulement du moteur et de débalancer ou de rendre bruyante l hélice du moteur gardez l appareil à l abri des poussières de gypse ou de construction rénovation etc 3 Cet appareil est muni d une hélice non protégée Ne pas utiliser dans des endroits faciles d accès autant pour des personnes...

Страница 8: ...e l intérieur du grenier mesurer et tracez un repère au milieu des chevrons du toit le plus près possible de la position du ventilateur Tirer une ligne parallèle aux chevrons Mesurer depuis le faîte du toit la même distance qu à l étape 1 et inscrire cette mesure sur la ligne centrale entre les 2 chevrons 3 Percez un avant trou dans le toit au niveau du repère 17 14 3 8 4 Découpez le gabarit rouge...

Страница 9: ...de d un pied de biche enlever les clous des bardeaux du haut jusqu au deux tiers du carré de 23 po dessiné sur le toit 9 Couper les planches du toit à l intérieur de la ligne Ne pas couper les chevrons INSTALLATION SUITE INSTALLATION SUITE 11 Glisser le solin sous les bardeaux Commencer au deux tiers du carré de 23 po à partir du haut Ne pas plier les bardeaux plus que nécessaire Centrer le ventil...

Страница 10: ...RE EFFECTUÉS PAR DU PERSONNEL QUALIFIÉ EN RESPECTANT LES NORMES ET RÈGLEMENTS EN VIGUEUR Y COMPRIS CEUX DU CODE NATIONAL D ÉLECTRICITÉ 1 Retirer le couvercle du boîtier de raccordement électrique du thermostat Insérer au moins 6 po de câble électrique dans ce boîtier Fixer le câble au boîtier avec un connecteur approprié MOTEUR COMPARTIMENT ÉLECTRIQUE DU VENTILATEUR NOIR TERRE BLANC NOIR BLANC TER...

Страница 11: ...ir actionner le ventilateur position ON ou faire cesser son fonctionnement position OFF de façon manuelle 3 Remettre en place le couvercle de métal du boîtier de raccordement électrique du thermostat et le fixer solidement 4 Le réglage du thermostat détermine la température à laquelle le ventilateur se mettra en marche Le ventilateur s arrête automatiquement lorsque la température du grenier est d...

Страница 12: ...e SAE n 20 6 Réassembler les pièces en s assurant que le moteur est dans sa position originale dans son support L hélice doit aussi être replacée en position originale sur l arbre du moteur ENTRETIEN SUITE ENTRETIEN PAR LE GRENIER 1 Retirer les trois boulons 1 4 9 retenant l ensemble du moteur au solin 5 2 L ensembledumoteurtomberaunefoislestroisboulonsenlevés PRENDRE SOIN DE NE PAS DÉFORMER LES P...

Отзывы: