In the CLI Utility window, click the checkbox for
Enable
Any CLI Command
.
To activate the license, in the Command field, enter:
license load file://localhost/<file path>
where <file path> is the name and location of the license
file on the appliance.
NOTE:
Filenames are case sensitive. Make sure to enter
the license filename with the same upper and lower case
characters entered when the file was saved.
4. To reboot, in the Command field, enter:
reset
NOTE:
Rebooting the appliance may take several min
-
utes or longer, depending on the network. DO NOT un
-
plug the power cords during reboot, as this can corrupt
the configuration.
5. After the appliance reboots, to verify the license’s attri
-
butes and expiration date, return to the appliance’s Man
-
agement Console window and go to the
Info
tab.
6 — Perform a Graceful Shutdown
Before mounting the appliance, log in to CLI and perform a
graceful shutdown of the appliance.
To perform a graceful shutdown:
1. Open a terminal emulation program and log in to the
appliance.
NOTE:
Confirm the appliance’s
DB9 Serial
port is con
-
nected to a serial terminal or workstation and that the ter
-
minal emulation software is configured as in
2. When prompted with the Serial Console welcome
screen, to access CLI, press:
1
3. To access privileged commands, enter:
enable
4. When prompted, enter the enable
Password
specified
during the initial configuration.
5. Enter:
shutdown
WARNING!
Do not power off the appliance with the soft pow
-
er switch or by removing the power cables! Abruptly removing
power can result in irreparable data loss. Always use the
shutdown
command from CLI to power off the appliance.
7 — Mount the Appliance
The fixed-mount brackets included with the PC
-
S200 allow
it to be installed into a 4- or 2-post equipment rack. An
optional slide-rail kit is also available.
NOTE:
To rack-mount the appliance, you need a #2 Phillips
head screwdriver and rack screws.
NOTE:
For information on installing the optional slide rails, see
the
S-Series WebGuide
, available at:
Rack Warnings and Precautions
CAUTION!
Before mounting the appliance:
) and disconnect all cables.
Verify that the weight of the system does not exceed the
rack’s fully populated weight limit. For more information,
refer to the manufacturer’s instructions included with
the rack.
For weight stability, load the rack from the bottom up.
Read the “Rack Mount Warnings” section of the
Safety
and Compliance Guide
.
Take adequate safety and grounding measures to avoid
creating an electrical shock hazard and to prevent
bodily injury.
Do not place objects on the appliance or use it as a
work surface. Its mounting hardware does not support
additional weight.
Figure 2: PC
-