background image

MegaRAID SAS 9361-24i RAID Controller Quick Installation Guide

 

February 20, 2017

Driver Installation 

Figure 2

. Create New Virtual Drive Screen

Install

ing the Driver

All driver installation instructions are available at 

https://www.broadcom.com/support/download-search

Access this site, then select 

Storage Adapters, Controllers, and ICs > All Storage Adapters, 

Controllers, and ICs > MegaRAID SAS 9361-24i > Driver.

Replacing the Bracket on the MegaRAID SAS 9361-24i RAID 
Controller

To replace the bracket on the Broadcom 12Gb/s SAS RAID controller, follow these steps:

1.

At an ESD-safe workstation, remove the controller from its ESD protective bag.

ATTENTION:

Never apply pressure to the bracket or the heat sink when inserting the controller. Do not 
handle the controller by the bracket. Do not handle the heat sink at any time. Do not bend 
or twist the controller at any time.

2.

Use an ESD-safe #No.1 Phillips screwdriver to carefully remove the two Phillips screws that 

connect the bracket to the controller.

 The following figure shows how to unscrew the two screws 

located at the top edge and bottom edge of the controller.

ATTENTION:

Damaging the screw can void the warranty. To prevent damage to the screw, make sure 
that the screwdriver is centered in the top of the screw.

Содержание MegaRAID SAS 9361-24i

Страница 1: ...these steps 1 Unpack the controller Unpack the controller in a static free environment Remove it from the antistatic bag and inspect it for damage A low profile bracket is included with the RAID controller If you notice any damage contact Broadcom or your reseller support representative ATTENTION To avoid the risk of data loss back up your data before you change your system configuration 2 Prepare...

Страница 2: ...the required airflow for the controller Airflow must be at least 300 linear feet per minute LFM at 50 C inlet temperature to avoid operating the SAS3324 processor above the maximum junction temperature 7 Replace the cover and reconnect any cords and cables and power up the system Replace the chassis s cover reconnect any power cords and reconnect any network cables Turn on the power 8 Run the Mega...

Страница 3: ...ntroller follow these steps 1 At an ESD safe workstation remove the controller from its ESD protective bag ATTENTION Never apply pressure to the bracket or the heat sink when inserting the controller Do not handle the controller by the bracket Do not handle the heat sink at any time Do not bend or twist the controller at any time 2 Use an ESD safe No 1 Phillips screwdriver to carefully remove the ...

Страница 4: ...9361 24i RAID Controller Figure 3 Removing the Screws 3 Keep the controller on a level surface to make sure you do not lose any retaining clips The heat sink is held in place by the same screws that attach the bracket The black retaining clips shown in the following figure can come loose when the screws are removed 3_03574 ...

Страница 5: ...screws Doing so might damage the thermal interface material which causes the controller to overheat during operation Damage to the heat sink or the interface material while changing the bracket might void the controller warranty 4 Place the controller on top of the replacement bracket Place the controller on top of the replacement bracket Make sure to position the bracket so that the screw holes i...

Страница 6: ...oadcom refers to Broadcom Limited and or its subsidiaries For more information please visit www broadcom com Broadcom reserves the right to make changes without further notice to anyproducts or data herein to improve reliability function or design Information furnished by Broadcom is believed to be accurate and reliable However Broadcom does not assume any liability arising out of the application ...