TECHNICAL SUPPORT
For assistance installing, configuring, or running
the HBA, contact Avago Technical Support:
WARRANTY NOTICE
1.
The warranty does not cover the return of
parts damaged by changing the bracket.
2.
The warranty does not cover ESD damage to
the HBA. HBAs returned without a bracket
mounted on the board will be returned without
return merchandise authorization (RMA)
processing.
Web Site:
www.avagotech.com
For product information and a complete list of distributors, please go to our website:
www.broadcom.com
.
Broadcom, the pulse logo, Connecting everything, Avago Technologies, and the A logo are the trademarks of Broadcom in
the United States, certain other countries and/or the EU.
Copyright © 201
7
Broadcom. All Rights Reserved.
www.broadcom.com
.
Broadcom reserves the right to make changes without further notice to any products or data herein to improve reliability,
function, or design. Information furnished by Broadcom is believed to be accurate and reliable. However, Broadcom does
not assume any liability arising out of the application or use of this information, nor the application or use of any product or
circuit described herein, neither does it convey any license under its patent rights nor the rights of others.
pub-005708
January 31
, 201
7
.
Figure 1
. Installing the 9400-16e HBA in a PCIe Slot
NOTE: This example shows the 9400-16e HBA being installed. The 9400-8e HBA is connected in the
same way. The difference between the two adapters is that the 9400-16e HBA supports 16 ports,
and the 9400-8e HBA supports eight ports.
6.
Connect the cables between the adapter and the enclosure or the storage devices.
The 9400-
16e HBA has four SFF-8644 external x4 Mini SAS HD connectors and the 9400-8e HBA has two SFF-8644
external x4 Mini SAS HD connectors. Use cables with an external Mini SAS HD connector on one end (to
connect to the HBA) and the appropriate connector on the other end to attach to the enclosure or the
storage devices.
7.
Make sure the system provides the required airflow for the controller.
The following table
shows the required airflow and the inlet temperature for the 9400-16e HBA and the 9400-8e HBA. The
adapter requires appropriate airflow and inlet temperature to avoid operating the SAS3416 I/O controller
or the SAS3408 I/O controller above the maximum junction temperature.
8.
Replace the cover and reconnect any cords and cables, and power up the system.
Replace the
chassis cover, reconnect any power cords, and reconnect any network cables. Turn on the power.
The hardware installation of your 12Gb/s SAS HBA is complete.
Driver Installation
The firmware and drivers are routinely updated and made available on the Support and Download
center. Please visit
http://www.avagotech.com/support/download-search
firmware and driver for the controller.
PCIe Adapter
Airflow
Inlet Temperature
9400-16e
200 LFM
55 °C
9400-8e
200 LFM
55 °C
Edge of Motherboard
PCIe Slot
Bracket Screw
Press
Here
Press
Here
3_03255