CETECOM Inc.
Test report no.:EMC_381EN328-2002
Issue date:2003-01-10
Page 8 (33)
EFFECTIVE ISOTROPIC RADIATED POWER
CLAUSE 5.2.1
TRANSMITTER POWER (dBm)
EIRP
TEST CONDITIONS
Low frequency
2412MHz
Mid frequency
2442MHz
High frequency
2472MHz
T
nom
( 23 )
0
C V
nom
(3.3)
Pk
15.14
Pk
15.64
Pk
15.64
T
min
( 0 )
0
C V
nom
(3.3)
Pk
15.15
Pk
16.09
Pk
15.85
T
max
( +70 )
0
C V
nom
(3.3)
Pk
15.41
Pk
15.93
Pk
15.71
Av – Average power during Burst
LIMITS:
CLAUSE 5.2.1
Under all test conditions
≤
20dBm / -10dBW / 100mW