background image

DUAL G703 Detector 

B044  

Configuration and operation 

 2004 dB Broadcast Ltd 

 Version 1.0 

Selecting the relay drive signal 

Each channel has a relay with two sets of contacts, which may be driven from one of four 
detected error signals. 

The error signals are: 

Error 

JP1 
CH A 

JP2 
CH B 

Description 

Frame 

FRM 

FRM 

Loss of framing or multi-framing (if enabled) 

Level 

LVL 

LVL 

Signal level below threshold set by RV1 (CHA) or 
RV2 (CHB) 

AIS 

AIS 

AIS 

Alarm insertion signal present (AIS & TS16 AIS) 

CRC-4 

CRC 

CRC 

Quality below CRC-4 threshold (if enabled) 

 

 

Selecting the micro-controller mode 

The micro-controller may be operated in one of three modes: 

Mode 

JP3 position 

Description 

 

Near front panel 

Not used 

CRC4 

CRC4_1 

CRC-4 threshold alarm enabled (default) 

CRC4 

CRC4_2 

CRC-4 threshold alarm disabled  

MF-Dis 

MF-Dis 

Multi-frame disabled 

 

 

 

 

 

 

 

 

 

 

 

Содержание B044

Страница 1: ...B044 DUAL G703 DETECTOR Handbook Version 1 0...

Страница 2: ...ses only and does not constitute any form of warranty or guarantee All trademarks acknowledged The information in this document is subject to change without notice dB Broadcast Ltd Registered Office K...

Страница 3: ...DUAL G703 Detector B044 2004 dB Broadcast Ltd D Do oc cu um me en nt t h hi is st to or ry y Date of first publication 12 06 2004 Current issue and date Board issue numbers covered 259 044 011...

Страница 4: ...onnections 4 CONFIGURATION AND OPERATION 5 Front panel control 5 CONFIGURATION 6 Channel A link functions and adjustments 6 Channel B link functions and adjustments 6 Mode selection affects both chann...

Страница 5: ...Volt rails The B044 dual G703 detector The module monitors two incoming signals and provides active loop through outputs on BNC s and provides local indications on the front panel of the module It als...

Страница 6: ...ollectors Any one of the four alarms is selectable to the summary alarm Relay Four alarms Signal level indication Alarm insertion signal present AIS TS16 AIS Loss of Framing or Multi Framing CRC 4 qua...

Страница 7: ...ti io on n Selecting rear connectors The available rear connectors and the frames signal I O used are as follows Type Frame Connectors Signal types VMC 3306K 1U 3U Avitel BNCs G703 at 2 048MHz VB110 1...

Страница 8: ...1 Ctrl 0V 14 0V 2 Not connected 15 Relay B1 Com 3 Frame Error A open collector 16 Relay B1 NC 4 Level Low A open collector 17 Relay B1 NO 5 AIS Present A open collector 18 Relay B2 Com 6 CRC 4 High A...

Страница 9: ...ed from front panel Level Green Input selection controlled remotely CRC Yellow Indicate G703 error detection Controls Threshold Signal loss threshold adjustment Avitel Vistek LED Ext Alrm Meaning when...

Страница 10: ...CRC see next section RV1 Adjust signal loss threshold JP10 Fit this jumper to enable voltage spike suppression on the Channel A input Channel B link functions and adjustments Adjustment Main Module C...

Страница 11: ...Loss of framing or multi framing if enabled Level LVL LVL Signal level below threshold set by RV1 CHA or RV2 CHB AIS AIS AIS Alarm insertion signal present AIS TS16 AIS CRC 4 CRC CRC Quality below CR...

Страница 12: ...e frame Check that the appropriate rear connector has been cabled correctly The Level LED keeps blinking on and off for good signals Check that the front panel threshold sensitivity is set correctly t...

Страница 13: ...cluded MPS 3392L PSU for above chassis no PSUs included VMC 3306K BNC Rear connector module no PSUs included 1U Avitel configuration ERF 1131K 1U Chassis 3 Module slots PSU mounted externally no PSUs...

Страница 14: ...0 Version 1 0 S Sp pe ec ci if fi ic ca at ti io on n INPUTS OUTPUTS Interface G703 75 Ohm or 120 Ohm factory fitted option with active loop though outputs Framing CRC4 Multi frame or Non CRC4 Data ra...

Отзывы: