background image

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742

14

AES Audio Sentinel

®

+ Web Installation and Operation Manual

OPERATION

Step 4:

On the Local Area Connection Properties page, double click on 

Internet

Protocol (TCP/IPv4) 

to display properties.

Step 5:

Before making any changes to the network settings, write down the current

settings (or screen capture the page and print) so that they can be restored
once the unit is configured.  Next, select the radio button labeled 

“Use the

following IP address”

and type in the IP address 

192.168.1.60

.  Type in the

subnet mask of 

255.255.255.0

.  Leave the default gateway field blank.

Click OK to apply the new settings.

WEBSITE:

Visit our web site for
product updates and
additional information.

Содержание AES Audio Sentinel + Web

Страница 1: ...arks of Broadcast Tools Inc Copyright 1989 2019 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www broadcasttools com for...

Страница 2: ...8 Audio Input Connections 9 Audio Output Connections 9 Remote Control Connections 10 LAN NET Jack 10 Chassis ground 10 Operation 11 Reset to Defaults 11 Ethernet Quick Start Guide 12 Opening the LOGI...

Страница 3: ...contact a properly qualified engineer to handle the installation and setup of the AES Audio Sentinel Web Broadcast Tools Products as with any electronic device can fail without warning Do not use thi...

Страница 4: ...itoring config uration and control Front panel remote and web based switcher controls Both AES inputs feature silence sensors phase monitors with front panel activity and alarm LED indicators Silence...

Страница 5: ...entinel and connected equipment if it is not properly protected For lightning protection devices check out www polyphaser com and www itwlinx com UPS Standby Power System We recommend that you connect...

Страница 6: ...tton option is engaged Green Front Panel Switching Controls 1 and 2 pushbuttons Used to select which input is routed to the output when in Manual mode Each push button has an LED indicator which will...

Страница 7: ...nob Fed by the internal DACs SW7 Fixed PM Powered Monitor Switch The recessed Fixed PM switch toggles the Analog Out monitor output audio between a fixed output level 4 dBu mode and a power monitor mo...

Страница 8: ...of 0 25 and insert the conductor fully into the terminal Turn the capture screw fully clockwise to secure the conductor Verify that no bare wires are exposed XLR Connector Pinout The input and output...

Страница 9: ...ut AES Silence Sensor 1 XLR F and RJ45 AES In 2 Backup AES input AES Silence Sensor 2 XLR F and RJ45 AES Output AES Switcher Output XLR M and RJ45 AES EBU signal switching is accomplished via mechanic...

Страница 10: ...T K3 and K4 relays are each available for user configurable notification The operation of K3 K4 is determined by the configuration assigned on the Silence Sensor Setup page Top row TB2 K4NO K4CM K4NC...

Страница 11: ...witch the backup input to the output and Manual Mode where switching control must be performed manually via the front panel controls web controls or remote control inputs Email and SNMP alarm notifica...

Страница 12: ...will be used for the configuration of this product are given here Note that these instructions are specif ically for computers with the Windows 7 operating system For setup using other operating syst...

Страница 13: ...lled Change adapter settings The Network Connections windows will pop up as shown below Step 3 Right click on the icon labeled Local Area Connection or Ethernet A menu will appear Select the option at...

Страница 14: ...ore making any changes to the network settings write down the current settings or screen capture the page and print so that they can be restored once the unit is configured Next select the radio butto...

Страница 15: ...d the products NET network RJ45 s jack 2 Connect the supplied PS 1515 power supply Verify that the green PWR Heartbeat LED is blinking and the left LINK LED above the NET Network RJ 45 is illuminated...

Страница 16: ...6 783 1742 16 AES Audio Sentinel Web Installation and Operation Manual WEB SETUP Web Setup and Operation Login Web Page The Login screen displays the Username and Password entry points WEBSITE Visit o...

Страница 17: ...played Depending on your access level you may or may not be able to control or modify the product s configuration Monitor Control Web Page The Monitor Control page allows the monitoring and or control...

Страница 18: ...lected as denoted by the LED being illuminated Monitor Input buttons Control analog monitor headphone audio outputs The user may switch between each input by placing the cursor under each input LED th...

Страница 19: ...ete configuration access and control 2 Monitor Control allows the following access About Monitor Control Show log Help and Logout 3 Monitor Only allows the following access About Monitor only Help and...

Страница 20: ...Web Installation and Operation Manual WEB SETUP I O Setup Web Page The I O setup page allows you to label and configure both AES inputs silence sen sors as well as configure the relay output and remo...

Страница 21: ...Manual mode EXTernal Sustained Holding the RMT3 input low switches the unit to the backup input releasing returns to the primary input Monitor Audio Switching Mode Follow AES Analog monitor audio out...

Страница 22: ...valid stereo audio to return and remain present before the unit clears the alarm and if in automatic bouce mode switches back to input ONE from input TWO Trip Level db The left right or both input le...

Страница 23: ...ched to or inactive not switched to The logic for each relay is as follows When input 1 or input 2 Is Active Inactive Silent or AES Error delay X sec onds then Engage for X seconds NOTE Delay timing 0...

Страница 24: ...asttools com voice 360 854 9559 fax 866 783 1742 24 AES Audio Sentinel Web Installation and Operation Manual WEB SETUP Email Network Setup Web Page WEBSITE Visit our web site for product updates and a...

Страница 25: ...dicate they are from this address If an email cannot be delivered a mes sage stating why will be sent to this address SMTP Host ID Enter string here to identify the device No spaces or special charact...

Страница 26: ...if the Snapshot Interval is less than the Update Interval Each snapshot will be identified by the date and time Email Network Setup Web Page Email Alarm Settings Email Alarms Choose Immediate and or...

Страница 27: ...unity This is the community name used for Read Only access SNMP Write Community This is the community name used for Read Write access NOTE A cold start trap will be sent when the unit boots up if the...

Страница 28: ...year boxes can be used to set the time of the real time clock The time is only updated if you click Save Time and not when you Save Settings Enable Event Logging Event logging will generate an alarm...

Страница 29: ...After you are done making changes to the Email Network Setup page you MUST press the Save Settings button to save your changes Reload Defaults When you press the Reload Defaults button the device res...

Страница 30: ...shold In Phase Stereo audio exited out of phase alarm Out of Phase Stereo audio entered out of phase alarm AES Error Error flag from AES receiver AES signal error or loss Controls Disable Sound Mutes...

Страница 31: ...ation Manual WEB SETUP About Web Page The About web page displays the product name firmware version numbers and Broadcast Tools web site link For firmware updates please contact Broadcast Tools Techni...

Страница 32: ...65535 seconds 18 hours 12 minutes and 15 seconds Remote Control Inputs Closure to ground Sustained or momentary depending on mode Internally pulled up to 5 VDC Relays K4 K5 K6 K7 K4 K5 K7 SPDT K6 STST...

Страница 33: ...ies NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED T...

Страница 34: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 AES Audio Sentinel Web Installation and Operation Manual 34 APPENDIX...

Страница 35: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 35 APPENDIX...

Страница 36: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 36 APPENDIX...

Страница 37: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 37 APPENDIX...

Страница 38: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 38 APPENDIX...

Страница 39: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 39 APPENDIX...

Страница 40: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 40 APPENDIX...

Страница 41: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 41 APPENDIX...

Отзывы: