12

Smart Relay 4 G2 Installation and Operation Manual

PROGRAMMING

Set Modes

Each of the four channels can be programmed with its own independent mode/logic
function. See the Mode Settings section of this manual for information on the modes
available. The default mode for each channel is: 00.

Current Mode Settings:
CH1:  00
CH2:  00
CH3:  00
CH4:  00
Select1-4

1. Type the channel number 1, 2, 3 or 4.
2. Type a timer value of as a two-digit value (00-15). For example, to set a

channel to mode 05 type: 05 and press enter. To return to the Program menu
press the ESC key.

To exit Program mode, press the ESC key until “EXIT PGM” is displayed. Program
mode will be exited automatically after 60 seconds of keyboard inactivity.

Restoring to factory defaults:

The default program values may be reloaded at any time by removing power from
the Smart Relay 4 G2, holding down the front panel Defaults (Def.) button and
plugging in the power and then releasing the Defaults button after a few seconds.

WEBSITE:

Visit our web site for
product updates and
additional information.

Содержание SR-4 G2

Страница 1: ...are registered trademarks of Broadcast Tools Inc Copyright 1989 2021 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www b...

Страница 2: ...rotection 5 UPS Standby Power System 5 LED Indicators 5 USB Serial PGM Port 5 Inputs 6 Input Jumper Configuration 7 Relay Outputs 7 Operation Overview 8 Channel Pinouts 8 Mode Settings 9 Programming P...

Страница 3: ...Smart Relay 4 G2 Broadcast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hardware software problems If you experience these problems please rese...

Страница 4: ...ude sustained toggle set reset flip flop dual alternate action or failing rising edge along with additional Boolean logic functions Independent pulse stretcher or time delays may be user programmed fr...

Страница 5: ...r high voltage surges may damage your Smart Relay 4 G2 and connected equipment if it is not properly protected For lightning protection devices check out www polyphaser com and www itwlinx com UPS Sta...

Страница 6: ...external resistor is nec essary if the input voltage is between 5 and 24 VDC Higher DC voltages from 25 to 48 VDC can be used but must be reduced with an additional external resistor of the appropria...

Страница 7: ...lace ONE jumper over pins 2 3 Relay Outputs The Smart Relay 4 G2 s relays are 2PDT normally open dry Make your connections to the desired relays K1 A B thru K4 A B Front panel LEDs indicate when a rel...

Страница 8: ...ctory default mode setting is Mode 00 where the relay closes when the odd input is active and opens when the odd input is inactive See the Mode Settings and Programming sections of the manual for more...

Страница 9: ...elay opens after the trailing edge is closed for the time period Mode 05 Relay output closes on leading edge of the odd input for time period Mode 06 Relay output closes for the time period on the tra...

Страница 10: ...il support broadcasttools com voice 360 854 9559 fax 866 783 1742 10 Smart Relay 4 G2 Installation and Operation Manual OPERATION WEBSITE Visit our web site for product updates and additional informat...

Страница 11: ...application like PuTTY Tera Term or HyperTerminal configured for the connected COM port set to 9600 baud 8 N 1 flow control to NONE Emulation set to ANSI and local character echo enabled Programming...

Страница 12: ...r 4 2 Type a timer value of as a two digit value 00 15 For example to set a channel to mode 05 type 05 and press enter To return to the Program menu press the ESC key To exit Program mode press the ES...

Страница 13: ...r with non volatile memory USB Serial 9600 8 N 1 USB type B female FTDI Chipset Connectors Inputs and Relay Outputs 4 6 position pluggable screw terminal blocks Power 9 to 12 VDC only greater than 500...

Страница 14: ...NO OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO I...

Страница 15: ...and Operation Manual 15 APPENDIX K1 K2 K3 K4 USB PGM PWR Def RELAYS INPUTS Smart Relay 4 G2 1 2 3 4 5 6 7 8 PWR 9 12 VDC Chs Gnd 1A 3A 1B 3B 2A 4A 2B 4B GND GND R1 R2 5A 7A 5B 7B 6A 8A 6B 8B GND GND R...

Страница 16: ...K2 K3 K4 3 4 N3 J3 S1 C C 9 C C U15 R07 C20 C19 U15 74HC04 LED3 U U14 RN5 U14 LED2 LED4 74HC04 C 1 C C F C C C C C F D1 FT23 1 C 1 2 C L5 1 C1 RN3 C01 C09 LED4 RL R 32RL U02 C02 U01 18F25K22 R04 JP2...

Страница 17: ...Relay 4 G2 Modified 04 29 21 131 State Street Sedro Woolley WA 98284 360 854 9559 Fax 866 783 1742 Copyright 1989 2021 by Broadcast Tools Inc All Rights Reserved Visit us online at www broadcasttools...

Отзывы: