Silence Sentinel
®
Basic Installation and Operation Manual
PROGRAMMING
K1 & K2 relay connections
External equipment to be controlled should be attached to the terminal J2 labeled
KxNO, KxCM and KxNC (where x is the control relay number) for relay 1 or 2.
NOTE: If mechanical latching relays are required, we suggest the Broadcast
Tools LR-5 (4PDT & SPST) mechanical latching relay.
Remote “Disable/Alarm Reset” input connection
The remote disable/alarm reset switch should be connected between the disable and
ground terminals on J2. The remote disable/alarm reset input requires a sustained
closure to ground.
NOTE: If the front panel disable/alarm reset switch is
engaged (unit disabled), then the remote input is disabled.
Power/HB LED
The flashing LED Indicates valid power and that the control processor is operating.
Programming Guidelines
DIPSwitch Setup
Locate dipswitch S1 on the front of the unit and follow the grid below.
Delay Time (SW1-9 ON) SW1-1 SW1-2 SW1-3 SW1-4
Restore SW1-5
SW1-6
Delay SW1-9
Delay Time
Resolution
OFF / Instant
OFF
OFF
OFF
OFF
OFF/Instant OFF
OFF
2 seconds
OFF
2 Sec (20 Sec)
ON
OFF
OFF
OFF
5 seconds
ON
OFF
20 seconds
ON
4 Sec (40 sec)
OFF
ON
OFF
OFF
30 seconds OFF
ON
6 Sec (1 Minute)
ON
ON
OFF
OFF
90 seconds ON
ON
8 Sec (1 Minute, 20 sec)
OFF
OFF
ON
OFF
Mode Select
SW1-10
10 Sec (1 Minute, 40 sec)
ON
OFF
ON
OFF
Stereo Mode *
OFF
12 Sec (2 Minutes)
OFF
ON
ON
OFF
Dual monaural
ON
mode.
14 Sec (2 Minutes, 20 sec) ON
ON
ON
OFF
Trip Level SW1-7
SW1-8
16 Sec (2 Minutes, 40 sec) OFF
OFF
OFF
ON
- 20dB
OFF
OFF
18 Sec (3 Minutes)
ON
OFF
OFF
ON
- 25dB
ON
OFF
20 Sec (3 Minutes, 20 sec OFF
ON
OFF
ON
- 30dB
OFF
ON
22 Sec (3 Minutes, 40 sec) ON
ON
OFF
ON
- 35dB
ON
ON
24 Sec (4 Minutes)
OFF
OFF
ON
ON
26 Sec (4 Minutes, 20 sec) ON
OFF
ON
ON
K2 Pulse length * JPR1
28 Sec (4 Minutes, 40 sec) OFF
ON
ON
ON
2 Second
OFF
30 Sec (5 Minutes)
ON
ON
ON
ON
20 Seconds