AES Audio Sentinel 4» Web Installation and Operation Manual
WEB SETUP
“Email/Network Setup” Web Page – NTP Settings
NTP Enabled:
Enable for NTP network time sync.
Default: Enabled
NTP (Time) Server Address:
Enter the NTP address here.
Default: pool.ntp.org
NTP Port:
Port used to connect to NTP server.
Default: 123
NTP Update Interval (Min):
Interval between time updates. Default: 60
“Email/Network Setup” Web Page – Other Settings
Site ID:
This is the Site Identifier that is displayed on the
web and in email.
Monitor Refresh Time (Sec):
Interval at which the Monitor page refreshes.
Shorter times may increase network traffic.
Time Zone Offset from UTC:
Sets the time zone used for the internal clock.
Default: -8
Enable Daylight Savings:
Adjusts the clock for daylight savings time.
Set Time:
The hour, minute, second, month, day and year
boxes can be used to set the time of the real time
clock. The time is only updated if you click “Save
Time” and not when you “Save Settings”.
Enable Event Logging:
Event logging will generate an alarm, but it will
not send an email. If the system is configured for
Daily Alarm emails, then that Daily Alarm email
will contain the event logging alarms as well as
the alarms configured on the I/O Setup page.
Login:
When someone logs into the unit, the username
and date/time will be logged.
Email:
When an email is sent, the type of email and
date/time will be logged.
Reboot:
When the device boots the date/time will be
logged.
Alarms Cleared:
When the Daily Logs or Normal Alarms are cleared,
the type of log cleared and date/time will be stored.
When Daily Logs are sent, the Daily Logs are also
cleared; this will cause an event log as well.