2x6 DA Plus Installation and Operation Manual

INSTALLATION

Installation/Operation

Power

Connect the supplied PS-1515 power supply’s 3-pin AMP-style latching power con-
nector to the unit and the +/-15 VDC switching power supply with domestic con-
nector into a 120 Vac 50-60 Hz power source.  The Power+ and Power- LEDs will
light to indicate proper supply voltage.
NOTE:  Never use any type of power supply other than the specified/supplied power
supply.

Surge Protection

The 2X6 DA PLUS has built-in resistance to voltage changes; we recommend that
you use a power surge protector or line conditioner on the incoming AC line.
Lightning strikes and/or other high voltage surges may damage your 2X6 DA PLUS
and connected equipment if it is not properly protected. For lightning protection
devices, check out www.polyphaser.com and www.itwlinx.com.

UPS Standby Power System

We recommend that you connect your 2X6 DA PLUS to a UPS system. A UPS helps
minimize the risk to the 2X6 DA PLUS and provides power during a power outage.

LED indicators

“Power+” and “Power-“ LEDs: Indicate positive and negative power supply.

“LT Act” and “RT Act” LEDs: Indicate left and right audio input activity.

Input Connection

Connect your audio source to the DA’s 5-position input terminal block. The input is
labeled: “INPUT” “L-“ “L+” for the left channel and “R-“ “R+” for the right chan-
nel. Connect the cable shields to G (ground) connection.  For unbalanced inputs,
install a jumper between the "-" input and G (ground). Single (mono) inputs may be
fed to all output channels by connecting the left and right inputs in parallel.

NOTE: Please verify proper phasing. 

Input Level Switch

The input on the 2x6 DA Plus can be switched between two gain ranges using the
rear panel “Input Level” switch. With the switch in the +4 dBu “in” position the
input gain is set to accept a +4 dBu nominal signal. With the switch in the -10 dBu
“out” position 12 db of gain is added to the input to accommodate consumer/low line
level input signals.

WEBSITE:

Visit our web site for
product updates and
additional information.

Содержание 2x6 DA Plus

Страница 1: ...tinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2015 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www broadcasttools com for important product update information Manual update 6 16 2015 If you need a firmware upgrade contact Broadcast Tools No part of this document may be reprodu...

Страница 2: ...tion 4 Installation Operation 5 Power 5 Surge Protection 5 UPS standby power system 5 LED indicators 6 Input connection 6 Input Level switch 6 Audio Output connections 6 Stereo Monaural Jumper Settings 6 Output Level adjustment 6 Specifications 7 Warranty 8 Front and rear panel drawings Appendix Connector and configuration jumper layout Appendix Fractional schematic Appendix WEBSITE Visit our web ...

Страница 3: ...Broadcast Tools Inc is unable to support NON Broadcast Tools software hardware or NON Broadcast Tools computer hardware software problems If you experience these problems please research your hardware software instruction manuals or contact the manufacturers technical support department WHO TO CONTACT FOR HELP If you have any questions regarding your product or you need assistance please con tact ...

Страница 4: ...BV or 4dBU sources eliminating the need for external level conversion Removable euro block screw terminal connectors are used for audio con nections Necessary mating plugs are supplied Fully RFI proofed Surge protected internal power supply PS 1515 universal switching 15VDC power supply with domestic connectors supplied International AC connectors optional Up to three units may be mounted on the o...

Страница 5: ...at you connect your 2X6 DA PLUS to a UPS system A UPS helps minimize the risk to the 2X6 DA PLUS and provides power during a power outage LED indicators Power and Power LEDs Indicate positive and negative power supply LT Act and RT Act LEDs Indicate left and right audio input activity Input Connection Connect your audio source to the DA s 5 position input terminal block The input is labeled INPUT ...

Страница 6: ...Stereo Monaural Jumper Settings Each stereo output can be set to output a monaural sum of the left and right input audio Follow the silk screened Mono labels on the PCB If the jumper is installed that output will be combined to monaural Placing a jumper over JP1 con verts output one to mono JP2 output two and JP3 addresses output three The fac tory setting is Stereo The three stereo outputs operat...

Страница 7: ...ut Impedance 100 Ω balanced 47 Ω unbalanced System Gain 20 dB Frequency Response 0 2dB 20Hz 20kHz Noise 75 dB below nominal Power PS 1515 universal switching power supply with domestic AC connector supplied International AC connectors optional 15 VDC 400mA output with 3 pin AMP style latching power connector Dimensions 6 x 5 25 x 1 63 in W x L x H Options RA 1 Rack Shelf 1 RU Accommodates up to 3 ...

Страница 8: ...O OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABIL ITY OR FITNESS FOR A PARTICULAR PURPOSE AND THE FOREGOING ALTERNATIVE REMEDIES SHALL BE EXCLUSIVE OF ALL OTHER REMEDIES THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL R...

Страница 9: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 2x6 DA Plus Installation and Operation Manual 9 APPENDIX ...

Страница 10: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 10 APPENDIX ...

Страница 11: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 11 APPENDIX ...

Страница 12: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 Product_Name Installation and Operation Manual 12 APPENDIX ...

Отзывы: