6
AES-408 DIP Switch Programming Guide of Operation Table 1.
S1-1 OFF = Front Panel Button Disables A/B and AUTO/MAN Buttons - Factory Default – ON
S1-6
Silence Indication on 1-8 Select buttons - ON = Enabled – Factory Default ON
S1-7
Unused
S1-8
Serial Control Enable - ON = Enabled - Factory Default ON
Digital Parameter Switch Selection:
S2-1
AES Error Switching Delay – Factory Default ON
S2-2
Unlock – ON - Factory Default ON
S2-3
Parity – ON -Factory Default ON
S2-4
- UNUSED -
S2-5
CRC
S2-6
Audio Bit
S2-7
Non-PCM Audio
S2-9
The AES-408 analog inputs can be sampled at 32, 44.1 or 48 KHz. The factory default setting is
44.1 KHz. To change the analog input sample rate as it appears at the AES3 output locate DIP
switch SW1 on the main board and make switch adjustments according to the chart below.
AES-408 Main PC Board DIP Switch SW1 Settings
DIPSWITCH1 1-4
ADC Sample
Rate
1
2
3
4
32 KHZ
ON
OFF
ON
ON
44.1 KHZ
OFF
ON
OFF
ON
48 KHZ
ON
OFF
ON
OFF