ENGLISH

Installation and 

User Manual

Please read this manual carefully and 

follow instructions exactly!

MOBILE

MANUAL

BRM 630 S

Elevator Emergency 

Communication Set

Содержание 630S

Страница 1: ...TD T Ostim OSB Mahallesi Al nteri Bulv No 29 36 Yenimahalle Ankara Phone 0850 220 28 81 Online Email brm brmelektronik com Website www brmelektronik com ENGLISH Installation and User Manual Please rea...

Страница 2: ...omatically Artificial intelligence is prepared to receive alarms of the battery It has a light system meeting requirements of the EN 81 70 or optionally relay outputs which can be connected with butto...

Страница 3: ...Module Antenna ATTENTION It should be installed in easily accessible places that will not be affected by water and moisture Follow these instructions during installation maintenance and application s...

Страница 4: ...ways ATTENTION If the 12V power input on the cabinet is taken directly from the revision battery the BRM Device measures the power level of your revision battery and can give you the necessary warnin...

Страница 5: ...elektronik com Cab Top Module to Main Module Connection Type 2 Type 3 Connection with 3 cables Main Module Cab Top Mod 1000 to the common 1000 line of the Panel Connection with 4 cables Main Module Ca...

Страница 6: ...le and the Pit Bottom Module can be connected to each other in 3 different ways The pit bottom module can be connected to the 12V line in the revision box 5 6 Kuyu Dibi Revizyon Kuyu Dibi Connection w...

Страница 7: ...m Main Module to Pit Bottom Module Connection 5 6 7 5 6 7 8 5 6 7 8 Connection with 3 cables Main Module Pit Bottom Mod Type 2 Type 3 Connection with 4 cables Main Module Pit Bottom Mod to the common...

Страница 8: ...www brmelektronik com 8 In Cab Module to Cab Top Module Connection A A Cab Top Mod In Cab Mod...

Страница 9: ...on 3 Cabin Module Please contact BRM Technical Support in case an interconnect module is required 90 555 109 57 40 Useage Areas Old type 530 N Cabin Module ARGESET Cabin Module AMETAL Amekon 3 Cabin M...

Страница 10: ...Connection Types ATTENTION Connection with It is made with the in cab module that written v 02 If the module you have is not v 02 please turn the end to with relay In Cab Mod Floating connection Worki...

Страница 11: ...m Button Connection Types ATTENTION If there are external led connections on the buttons panel the led connections can be made via BRM module Working With coming 12V when you press the button External...

Страница 12: ...www brmelektronik com 12 GENEMEK Connection Schema Green LED Yellow LED...

Страница 13: ...13 www brmelektronik com MEGA 7 V Connection Schema...

Страница 14: ...evice ATTENTION Connect by checking the and ends of the battery In case of reverse connection the battery input may be damaged BRM main module checks your battery and sends you the necessary warnings...

Страница 15: ...INGLE CABLE FILTERING FEATURE THROUGH BRM CLOUD Filtration Positions ENERGY there is 1 12 24 there is not 0 DOOR closed 1 12 24 open 0 ENGINE working 1 12 24 stopped 0 According to the standard extern...

Страница 16: ...or informational purposes only ENTRANCE 2 You can connect a module you want to monitor from the control panel and follow it through the system For informational purposes only RS 485 A For devices with...

Страница 17: ...n the engine room is searched automatically c If the intercom device does not respond for 15 seconds phone calls to other registered numbers d Intercom device talk time is 20 minutes e When the interc...

Страница 18: ...ard If the PIN code is not removed the device will make a card error and the system will not work Enter the Security Settings by inserting the sim card into a mobile phone cancel the PIN code from her...

Страница 19: ...14 shown in the PICTURE BELOW The signal strength of BRM630S models is between 1 31 Critical level device will inform V indicates battery power V 13 7 The battery is at 13 7 volts The above screen app...

Страница 20: ...efault password is 123456 You can change it later The setup will remain on for another 300 seconds with each successful SMS command Note Do not leave spaces between characters in SMS messages you writ...

Страница 21: ...ssword changing command is Sifre After writing Sifre without quotation marks write current password and leave a space then write new password Finally push the send button The password must consist of...

Страница 22: ...es as Tel1 Tel2 Tel3 Tel4 Tel5 An international code should be written at the beginning of the phone number When the above SMS is sent to the device the screen below should appear Tel1 905551095740 Te...

Страница 23: ...e is only one d and r as you see Up to 100 characters can be written including spaces Do not use special characters You must use the English alphabet When the above SMS is sent to the device the scree...

Страница 24: ...EQUIRED Start writing with Firma Up to 100 characters can be written including spaces Do not use special characters You must use the English alphabet When the above SMS is sent to the device the scree...

Страница 25: ...0 to 9 are available For example 0 Turkish 1 English 2 German When the above SMS is sent to the device the screen below should appear CHANGING THE MENU LANGUAGE ADDING OR REMOVING EXTERIOR DOORS TO T...

Страница 26: ...d address information Write Kaydet for save When the above SMS is sent to the device the screen below should appear FIRST STEP SAVING SETTINGS SECOND STEP COMMAND CLOSE Bitir Bitir Write Bitir for com...

Страница 27: ...er 10 seconds after the cabin doors are closed when the inside cabin alarm button is pressed for 20 seconds This time can be adjusted via BRM CLOUD the device switches to test mode after 3 times DIT s...

Страница 28: ...tery level Sound level imei no Status of the filters You can likewise use option 1 or 2 to exit test mode Seeing the BRM Software Version By pushing the test button you can see the software versions o...

Страница 29: ...he BRM CLOUD system 1 VIA BRM MAIN MODULE The alarm termination process occurs by pressing the alarm termination button on the BRM main module for 3 seconds 2 VIA BRM CLOUD After the rescue operation...

Страница 30: ...or determination of technical methods to apply in repairing the breakdown and parts to be changed Repair can be carried out in situ of the device authorized service workplaces or manufacturing site Ou...

Страница 31: ...owns originating from incorrect type selection If the device is not installed with equipment appropriately as shown in the installation image of the manual If the device is used in too humid or watery...

Страница 32: ...tomer Name and Surname Address Phone Seller Company Title Addres s Phone Date STAMP SIGNATURE WARRANTY DEED The T R Ministry of Science Industry and Technology and General Directorate of Consumer and...