EN-2
•
Do not place the heater near new walls, curtains or furniture while in operation. Always face the
heater towards the centre of the room when in use. Minimum clearance to combustibles to the
rear and sides of the heater behind the plane of the front panel 500 mm. Minimum clearance to
combustibles to the front panel 1.000 mm.
•
The heater must not be moved while operating.
•
Do not place objects on or against the heater.
•
The guard on this appliance is to prevent risk of fire or injury from burns and no part of it should
be permanently removed. IT DOES NOT GIVE FULL PROTECTION FOR YOUNG CHILDREN OR THE
INFIRM.
•
This appliance should be leakage tested before initial use and whenever the cylinder has been
reconnected after filling.
•
Always close the gas cylinder valve whenever the heater is not in use.
•
For the connection of this device you need an approved gas hose (BS3212 type 2 or BSEN1763
Class B) with a recommended length of 40 cm. It should be replaced if it appears to be damaged
or cracked. You need to check on this frequently. We recommend to replace the gas hose every 3
years.
•
The gas hose should be connected in such a way that it can’t be twisted.
•
You are obliged to replace the gas hose if national circumstances require.
•
This appliance is designed to operate with 5 kg till 15 kg butane or propane gas bottles, with an
adequate pressure reducing valve. See below schedule for gas and operating pressure:
Category
Gas and pressure
Countries
Injector
Heat input
I3+
(28-30/37)
Butane 28mbar /
Propane 37mbar
GB, IE, BE, CH, ES,
FR, GR, IT & PT
Main burner: 0,55mm
Pilot burner: 0,20mm
3,7kW (269gr/h)
I3 B/P
(30)
Butane / Propane
30mbar
DK, FI, GR, LU, NL,
NO & SE
Main burner: 0,55mm
Pilot burner: 0,20mm
3,7kW (269gr/h)
I3 B/P
(50)
Butane / Propane
50mbar
AT, CH & DE
Main burner: 0,48mm
Pilot burner: 0,18mm
3,7kW (269gr/h)
All manuals and user guides at all-guides.com