background image

brixlelektronik

...we got the solution

bc-12er   12 channel receiver 

bc-20 plus 20 channel receiver

Description 

bc-12er

The bc-12er is a 12 channel receiver designed for the brixlcontrol system. 
Supplying 12 universal channels, the bc-12er is the ideal unit for smaller models or  
trailers. Multiple units can be linked by either cable or infrared connections.
The 12 universal channels can be used as an output to drive servos, LED´s or PWM
controlled drivers. Some of the channels can also be used as inputs to be 
connected with sensors for telemetry purposes or as inputs for switches.
Technical data bc-12er
Supply voltage 

4V – 8V 

Outputs (universal)

12

Maxmimum load (output)

20mA

Analogue input (switch)

max 4

PWM output

max 5

PWM output for bc-msII

max 2

Dimensions

22 x 34 x 12 mm 

bc-20plus

The bc-20 plus is a 20 + 12 output receiver designed for the brixlcontrol system. 
This receiver is equipped with 20 universal channels that can be used as an output  
to drive servos, LED´s or PWM controlled drivers. Some of the channels can also 
be used as inputs to be connected with sensor for telemetry purposes or as 
inputs for switches. The bc-20 plus offers additional 12 outputs for on/off purposes 
with an internal driver for a maximum load of 100mA per output.

23.06.14 Vxx417

Connector for antenna

Ground -

Signal

Plus +

1

1

12

Picture 1

Содержание bc-12er

Страница 1: ...inputs for switches Technical data bc 12er Supply voltage 4V 8V Outputs universal 12 Maxmimum load output 20mA Analogue input switch max 4 PWM output max 5 PWM output for bc msII max 2 Dimensions 22 x 34 x 12 mm bc 20plus The bc 20 plus is a 20 12 output receiver designed for the brixlcontrol system This receiver is equipped with 20 universal channels that can be used as an output to drive servos ...

Страница 2: ... information Outputs universal 20 Outputs on off 12 Maxmimum load universal output 20mA Analogue input switch max 4 PWM output max 5 PWM output for bc msII max 2 Dimensions 30 x 60 mm 23 06 14 Vxx417 Connector for antenna Connector for infrared LED 12 on off outputs max 100mA load per output 12 on off outputs max 100mA load per output Ground Plus 20 universal outputs 1 20 Ground Plus Picture 2 ...

Страница 3: ...s below for further details bc 12er G G G G G G G G G G G G V V V V V V V V V V V V S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 P P P P P MP M M M DI O I V V G G bc 20 plus G G G G G G G G G G G G G G G G G G G G G G V V V V V V V V V V V V V V V V V V V V V S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11 S12 S13 S14 S15 S16 S17 S18 S19 S20 V M M M MP P P P P P DI P PN PN N N N N Led3 Led2 O Led1 I V V V V V V V V ...

Страница 4: ...established the blue LED on the tranmitter will light up and you can start programming the reciver Remarks The texts and terms in the programming menues are german and can not be translated by now This manual will use the german terms as they appear in the menues The english translation willl appear in brackets The term input device is used in the text for all devices on the transmitter that can b...

Страница 5: ... wich is permanently assigned to the built in status LED Funktion Status Feature Status With this feature you can assign a number to the the bc 12er module This is required for cable linked modules for remote programming This module number must be unique in one model and is only required for programming In normal operation all linked modules will get the information sent out by the transmitter If ...

Страница 6: ...le signal is 10 and 10 below A will reset the resetable hour meter BEC Wandler Ein bei Verb With this option the internal BEC system on the BEC on if connected bc 20 plus will be switched off when the module is in park mode saves energy while in park Immer Ein BEC will remain always on Servos will hold load Always on Aus b LoBat BEC will be disabled if the programmed min Off if battery low voltage...

Страница 7: ...device when the signal is fail safe lost or the transmitter is switched off halten Current position will be held hold kein Sig No servo signal send to the connected device no signal 125 Connected device will be set to the programmed position 0 Neutral signal will be provided 1 5ms Wie begrenzen ohne Feature disabled limtation of signal without Endschalter Pos 100 This output will be set to neutral...

Страница 8: ...nzung mit A z Defines the input device that controls the limitation limitation with input devices connected to the bc 12er can also control the limitation Ebeneschalter A z Defines the input device on the transmitter that Level control enables controls the different levels Ebenenestellung Defines on which level this output will work Level assignment use 3 position switch for proper control of the ...

Страница 9: ... when the module is powered up AusgangsSignal Puls Default setting for servos and esc Output signal PWM1 A 0 100 PWM signal will be provided on this output to be used with bc msII PWM2 100 100 PWM signal will be provide on this output to be used with bc msII Choosing PWM2 will also release the feature PWM Erweitert PWM extended which will only be uesd on the bc msII Please refer to the manual of t...

Страница 10: ... send to the connected device no signal 125 Connected device will be set to the programmed position 0 Neutral signal will be provided 1 5ms Ebenenschalter A z Defines the input device on the transmitter that Level control enabled controls the different levels Ebenenestellung Defines on which level this output will work Level assignment use 3 position switch for proper control of the levels E 0 A w...

Страница 11: ...the tranmitter Input device 3 Position switch recommeded here Gang1 125 125 Defines the position in gear 1 Gear 1 switch in down position Gang2 125 125 Defines the position in gear 2 Gear 2 switch in mid position Gang3 125 125 Defines the position in gear 3 Gear 3 switch in up position Funktion 6Gang Getriebe Feature 6 speed gear 6 positions can be programmed to control a 6 speed gear with a momen...

Страница 12: ...t 1 12 linked origin channel for the 6 speed gear G Position 1 6 125 125 Defines the 6 available positions for the linked Gear position connected device Funktion Raupe Links Feature Track mixer left With this feature you can control tracked models or models with one motor per side like a standard model This is the feature for excavaors or dozer to be controled in the same way as you are used to co...

Страница 13: ...ogrammed position 0 Neutral signal will be provided 1 5ms Lenkkanal A z Defines the input device of the transmitter Stick direction switch etc for the direction control Lenkung Zugabe 100 100 defines the increase of speed of the outer track steering increase Lenkung Abnahme 100 100 defines the decrease of speed of the inner track steering decrease Ebeneschalter A z Defines the input device on the ...

Страница 14: ...ue for the conncted device Min value Schnelligkeit 0 01 100 Maximum speed of the signal change for the Speed connected device Controls servo esc speed Funktion Raupe rechts Feature Track mixer right With this feature the second output for the track mixer will be defined Raupe links ist 1 12 Track mixer left is defined on output Track mixer left Gegenläufig Nein Normal movement of connected device ...

Страница 15: ...r proper control of the levels E 0 A works on all levels E 0 A works just in the upper level switch up E 0 A works just in the mid level sw Mid position E 0 A works just in the lower level switch down Funktion Licht LED Feature Light LED Senderkanal A z Defines the input device of the tranmitter Stick switch etc Input device Einschaltwert Defines the staus of the output when the module Default val...

Страница 16: ... A works just in the lower level switch down Gegenläufig Nein Normal Reverse no Ja Invers Feature inverted Yes Reverse Ausgabeart EIN AUS Defines switching points for on and off if a stick or Definition of switch pot is used to control this output Memory Ein Momentary switch moved to EIN down toggles Memory on output Memory Aus Momentary switch moved to AUS up toggles Memory off output EIN 0 AUS S...

Страница 17: ...lashes 0 is Off time Pause permanent on Funktion Blinker Links Feature Indicator Left This feature defines the settings for the output of an indicaor on the left side Senderkanal A z Defines the input device of the tranmitter Stick switch Input device etc Einschaltwert Defines the status of the output when the module is Default value power on powered up Warnbl Hazard lights both indicators on Haza...

Страница 18: ...genläufig Nein Normal operation Reverse no Ja Invers Reverse option US indicator style Yes Reverse Lenkkanal Sender A z Defines the input device that stops the indicator Steering channel Steering stick Ein Zeit 1 500 Defines the on time of the indicator On time Aus Zeit 1 500 Defines the off time of the indicator Off time Funktion Blinker Rechts Feature Indicator Right This feature defines the out...

Страница 19: ... between 2 2k and 10k and will be used as a voltage divider 0V 125 and 3 3V 125 Auf Kanal n z n z Which letter shall be assigned to this input Channel n z Please note Letters n x will be transmitted via infrared to linked modules Letters y and z will not be transmitted This will allow the usage of y and z exclusively on the module where the coresponding sensor is connected Please ensure the unique...

Страница 20: ...ressure using the Pressure brixl bc MM DR brixlelektronik sensor with the range of 0 0 35 bar This sensor is equipped with a 3mm thread for universal connection Please note that the range of the displayed pressure migh differ from the ranges printed on the sensors This is system related and ha no effect on the display values Min Alarm 0 0 100 0 If the measured value falls below this value an alarm...

Страница 21: ...tent swap between measuring values and hour meter Momentary switch is recommended for this option Screen content measuring values brixlcontrol status mv1 mv2 mv3 mv4 Akku 12 0V bc 20 plus only BEC 5 04V status can be either Spannung EIN Power supply on betrieb Connected to transmitter Empf konfig Receiver in programming mode Funkabriss Connection lost receiver in fail safe mode geparkt Receiver in...

Страница 22: ...ktion Mischer Feature Mixer only available in bc 20 plus This feature offers up to 6 completely free programmable mixers M1 to M6 The mixers can handle up to 8 different input devices Ausgang 1 32 M1 M6 Chosse the mixer to be programmed Output 1 32 MischerFunk Addierer All input devices will be added and send to Mx Mixer function Addition MaxWert The highest value will be sent to Mx Max value Misc...

Страница 23: ...brixlelektronik we got the solution bc 12er 12 channel receiver bc 20 plus 20 channel receiver 23 06 14 Vxx417 ...

Страница 24: ...d using this connection To program a module which is intended to be used via infrared an antenna must be connected directly and the module adress must be 0 Once programming is done the antenna can be removed an the infrad red connection can be used If you are using Servonaut or SGS equipment with multiple input lines motor control and steering or additional functions make sure that all inputs of t...

Страница 25: ... are running Servonaut speed controllers with cruise control options M20 E20 or similar we recommend to program a high negative value as fail safe for the throttle channel to ensure a proper behaviour in the case of a signal loss e g 60 to activate the brake funktion Within Europe This product is produced and labeled according to the Directive 2002 96 EC of the European Parliament and of the Counc...

Отзывы: