NOTE: Output Ratings for the ACS300
•
Two (2) reader ports, 11.4 - 12VDC, 350mA each
•
Two (2) selectable wet contacts, 11.4 - 12VDC, 350mA each
•
Four (4) dry contacts are 28VDC, 6A each
•
One (1) RS-485 port, 11.4 - 12VDC, 350mA
1.
Wire the REX & DOOR terminal block.
a)
Connect the Normally Open (NO) contacts of the REX device to the REX and COM
terminals.
•
When this switch closes, it initiates a Request-to-Exit (REX) program sequence,
as defined by the appropriate application, including the option to activate the
door or other relays, fire the door strike, and suppress any “Door Forced”
messages.
b)
Connect the Normally Closed (NC) contacts of the Door Sensor to the COM and
CONTACT terminals.
•
In this context, an NC switch is considered closed when the door is closed
(magnet is present), and open when the door is open (no magnet is present).
•
When the switch is
open, the control panel interprets this input as a “Door
Open” condition. When the switch is closed, the control panel interprets this
input as a “Door Closed” condition.
•
This circuit provides door status information (open/closed) to the control panel
so ACS Online can take appropriate action locally, or send email notifications if
necessary.
2.
Wire the DOOR LOCK RELAY terminal block.
a)
Connect the door latch to the COM terminal and either the NO or NC terminal.
b)
The DOOR LOCK RELAY provides both NO (Normally Open) and NC (Normally Closed)
contacts, and is driven in response to the presentation of valid credentials or the
programmable REX input.
c)
Timing and other aspects of relay activation are programmed through the Brivo
programming interface.
3.
If used for an alarm shunt, wire the AUX RELAY 1 terminal block. If not used for an alarm shunt,
AUX RELAY 1 can be used for a variety of purposes.
4.
Wire AUX RELAY 2. Like the AUX RELAY 1, this terminal block can be used for a variety of
purposes, and are programmed via the Brivo programming interface.
NOTE:
The fully programmable AUX RELAYs provide both NO (Normally Open) and
NC (Normally Closed) contacts.