BRIVO ACS300 

INSTALLATION MANUAL 

 

 

06/21/2019 

 

Содержание ACS300

Страница 1: ...BRIVO ACS300 INSTALLATION MANUAL 06 21 2019 ...

Страница 2: ...quipment and receiver Connect the equipment to a circuit other than the one to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including inte...

Страница 3: ...ocument is subject to change without notice and does not represent a commitment on the part of Brivo Systems LLC For the most up to date information visit www brivo com This document and the data herein shall not be duplicated used or disclosed to others for procurement or manufacturing except as authorized with the written permission of Brivo Systems LLC The information contained within this docu...

Страница 4: ... Brivo Systems LLC All rights reserved P MAN PUB Brivo ACS300 Installation Manual 4 Table of Contents INTRODUCTION 5 PRE INSTALLATION PROCEDURES 7 GENERAL ASSEMBLY PROCEDURES 10 POWERING AND TESTING PROCEDURES 14 INSTALLATION PROCEDURES 16 ...

Страница 5: ...f the manual are Pre Installation Procedures General Assembly Procedures Power and Testing Procedures Installation Procedures Terminology The following is a list of terms that are used throughout this document While some of these terms may have other meanings the definitions provided below are the ones intended in this Installation Manual Control Panel Brivo s one or two door Door Controller ACS30...

Страница 6: ...8 Yes Yes 1500 ft Door Contact 5500FE 22 Yes Yes 1500 ft Transformer Block 6300FE 18 Yes Yes 1500 ft Molex Connector N A 22 Yes No 1 ft Earth ground N A 6 Yes Yes 20 to 40 ft Reader Option 1 22 AWG 5504FE 22 Yes Yes 250 ft Reader Option 2 20 AWG 5400FE 20 Yes Yes 300 ft Reader Option 3 18 AWG 6300FE 18 Yes Yes 500 ft Additional Resources The following additional resources are available for the ins...

Страница 7: ...bit data and OSDP readers using RS 485 A current list of compatible readers and keypads is maintained on Brivo s website at http www brivo com If you have a specific model of reader or keypad that is not listed on the Brivo website please contact Technical Support at 1 866 BRIVO 4 U to determine compatibility Verify that the client site is ready to support the installation 1 Check with the IT depa...

Страница 8: ...between the ACS300 and its associated keypad or reader The ACS300 does not specify a maximum distance between the ACS300 and a keypad or reader but the keypad reader manufacturer does Follow manufacturer guidelines for each keypad and reader b Place the ACS300 within 500 feet of its associated electronic strike or latch Follow safety precautions WARNING Fire Code NEVER CONNECT A KEYPAD READER OR L...

Страница 9: ...s advisable to isolate it by using a high quality UPS Uninterruptible Power Supply between the AC Mains and the transformer This product is not intended for outside wiring as covered by Article 800 in the National Electrical Code NFPA 70 Unit is for indoor use only Power wiring attached to the ACS300 unit should be 26 AWG or larger Category 5 cabling is the minimum performance category recommended...

Страница 10: ...the ACS300 box using one of the three methods described below a Option 1 Use four bolts at the corners of the ACS300 enclosure to mount the ACS300 securely in place ACS300 Mounting Option One b Option 2 Looking at the back of the enclosure use two of the four bolts to hang the ACS300 board in place and then secure the enclosure with the remaining two bolts ACS300 Mounting Option Two ...

Страница 11: ...d cutouts mount the ACS300 enclosure to a 4 gang junction box ACS300 Mounting Option 3 5 Verify presence of optical tamper reflector on the inside lid of the ACS300 6 OPTIONAL Install the physical tamper switch in the ACS300 a Install the tamper switch in the ACS300 Confirm the SW 2 switch settings are in the correct positions ACS300 SW 2 Switch Bank Location ACS300 SW 2 Switch Settings ...

Страница 12: ...ionality OPTIONAL Connect the physical tamper switch to the ACS300 If the ACS300 unit is installed within an external metal chassis i e ACS6000 EXP the option for attaching an external physical tamper switch is provided Connect the physical tamper switch to the ACS300 Connect Tamper Switch to the ACS300 b The tamper header connects to the supplied tamper switch c The header connector for the tampe...

Страница 13: ...OUTLET OR OTHERWISE CONTROLLED AC OUTLET DO NOT CONNECT THE TRANSFORMER TO THE 120 VAC OUTLET UNTIL ALL WIRING IS COMPLETED 1 Use 18 AWG wire minimum grade to connect the screw terminals on the transformer to the POWER INPUT terminal block on the ACS300 using terminals DC AC1 and DC AC2 Compliance with IEEE 802 3 at or af specifications was not verified as part of UL294 B Connect AC Transformer to...

Страница 14: ... 12 VDC power b Check the ACS300 to confirm that the Health and Connect Status Lights have come on ACS300 Health and Connect Status Lights and Diagnostic LEDs Front Panel Meaning Health Connect Mostly Solid Slow blink every 15 seconds Solid Unit is healthy and connected to host server Mostly Solid Slow blink every 15 seconds Off Unit is healthy but not connected to host server Blinking Solid Unit ...

Страница 15: ...s 3 OFF ON OFF Unable to reach Brivo Server 4 OFF ON ON Time not known 5 ON OFF OFF Rebooted within the last hour 6 ON OFF ON Internal Fault within the last hour 7 ON ON OFF File corruption detected Device is damaged but still aware enough to indicate it cannot function properly 8 ON ON ON Device not registered configured ACS300 Diagnostic LEDs NOTE When an ACS300 is experiencing any issues shown ...

Страница 16: ...g and manual configuration utilities b The port uses auto sensing technology to determine polarity which permits either a straight or crossover cable to be used between the board and the computer Verify connection of the LAN to the ACS300 this should already have been done when powering up the ACS300 using Power over Ethernet Connect LAN to ACS300 1 Verify the connection of the LAN to the ACS300 a...

Страница 17: ...ly above it ACS300 Wiring Recommendation For each node to be used for controlling a door as indicated in the completed Installation Worksheet make the following connections NOTE The ACS300 has two Wiegand wiring blocks and one RS 485 wiring block The ACS300 can support up to two wired locks and up to 30 wireless locks with a total of 30 in any combination NOTE The RS 485 block can support an OSDP ...

Страница 18: ... open the control panel interprets this input as a Door Open condition When the switch is closed the control panel interprets this input as a Door Closed condition This circuit provides door status information open closed to the control panel so ACS Online can take appropriate action locally or send email notifications if necessary 2 Wire the DOOR LOCK RELAY terminal block a Connect the door latch...

Страница 19: ...DOOR 2 terminals on the left side of the ACS300 board 7 If using OSDP RS 485 readers wire the reader terminal to the RS 485 terminal on the upper left side of the ACS300 board Important RS 485 Wiring Information NOTE Ensure that when wiring the RS 485 bus that BOTH ENDS of the RS 485 bus are terminated using a 120𝛺 resistor NOTE When wiring the RS 485 bus use only twisted pair shielded wire NOTE T...

Страница 20: ...ACS300 board s factory default setting is Half Duplex communication when using RS 485 reader functionality In order to switch to Full Duplex communication move the HDX FDX switch to the Full Duplex position RS 485 Half Duplex Full Duplex Switch Location NOTE RS 485 bus requires termination The RS 485 termination switch is located in the upper left hand corner of the ACS300 ...

Страница 21: ... power by using Door 1 Wet Dry Switch above Door Node 1 and Door 2 Wet Dry Switch above Door Node 2 NOTE When powering a maglock through the ACS300 unit the lock relay must be set to Wet on the corresponding Wet Dry Switch Door 1 or Door 2 ACS300 Wet Dry Door Contact Switches for Doors 1 and 2 NOTE Refer to the Approved Wiegand and OSDP Reader List for Brivo approved devices and connection diagram...

Страница 22: ...r yellow reader wire to the BUZZ terminal This is the standard Buzzer circuit for the reader NOTE In regards to the BUZZ terminal please consult the manufacturer s wiring instructions to determine the color of the wire Connect the red reader wire to the 12VDC terminal This provides 12VDC to power the reader Connect the orange reader wire to the GRN LED terminal This is the green LED circuit Connec...

Страница 23: ... the wire recommended by the manufacturer of the electric strike or latch If no wire is recommended use a minimum of 18 AWG wire with sufficient strands for the specific electronic strike or latch Connect the ACS300 Wi Fi Antenna 1 The ACS300 Wi Fi antenna sits atop the mylar shield over the ACS300 board and already comes connected on the ACS300 unit Should it become detached and need to be reatta...

Страница 24: ...vo ACS300 Installation Manual 24 Ground the ACS300 1 When grounding the ACS300 unit use 18 AWG or larger wire to connect the ACS300 to a suitable earth ground 2 The ground contact point is the copper ringed screw point located in the lower left corner of the ACS300 board ACS300 Earth Ground ...

Страница 25: ...Government and removed reference to ACS300 S and Brivo Onsite 1 7 6 7 2017 LMW Added FCC 15B Class A and EN 55032 Class A language 1 8 11 9 2017 LMW Updated the SW 2 switch bank diagram and ACS300 board graphics replaced references to the Reader Keypad Wiring Guide with Approved Wiegand and OSDP Reader List and added the ACS300 Diagnostic LEDs table 1 9 11 22 2017 LMW Added a note after the ACS300...