BRIVIS CALL CENTRE  WALL CONTROL MANUAL 601 ISSUE 1 

29 

PROGRAMMABLE TH4110 

 

P

ROGRAM SCHEDULE OVERRIDE 

(

TEMPORARY

 
Press the 

UP

 and 

DOWN

 arrows to immediately adjust the temperature, this 

will temporarily override the temperature setting for the current time period. 
 
The new temperature will be maintained only until the next programmed time 
period begins.  
 
To 

cancel

 the temporary override at any time press 

RUN

 
P

ROGRAM SCHEDULE OVERRIDE 

(

PERMANENT

 
Press 

HOLD

 to permanently adjust the temperature. This will override the 

temperature settings for all time periods. 
 
The 

hold

 feature turns 

OFF

 the program schedule and allows you to adjust the 

thermostat 

manually

 
Whatever temperature is set will be maintained 

24hrs 

a day until you 

manually change it or press 

RUN

 to cancel 

hold 

and resume the program 

schedule. 
 
A

DAPTIVE INTELLIGENT RECOVERY 

(

AIR

 

Allows the thermostat to learn how long your heater or air conditioner takes to 
reach the set temperature. The thermostat turns the unit on at the right time to 
reach the desired temperature setting at the scheduled time. 
 
E.g. 

if the wake time is set for 6am and the temperature at 21. The unit will 

turn on before 6am to ensure that the temperature is at 21 by 6am. 

 
 
 
 
 
 
 
 
 

Содержание TH4110

Страница 1: ...o set the correct day of the week Press RUN to save SYSTEM SWITCH Switches between heating and cooling depending on which unit is selected COOL cooling system is in use OFF all systems are off HEAT heating system is in use FAN SWITCH Set the fan switch to AUTO or ON In AUTO MODE the fan runs only when the heating or cooling system is on If set to ON the fan will run continuously Use this setting f...

Страница 2: ... after they are all asleep ADJUSTING THE PROGRAM SCHEDULE Press SET until set schedule is displayed Press the UP and DOWN arrows to set your weekday wake time Mon Fri then press SET Press the UP and DOWN arrows to set the temperature for this time period then press SET Set the time and temperature for the next time period leave Repeat steps 2 and 3 for each weekday time period Press SET to set the...

Страница 3: ...ll override the temperature settings for all time periods The hold feature turns OFF the program schedule and allows you to adjust the thermostat manually Whatever temperature is set will be maintained 24hrs a day until you manually change it or press RUN to cancel hold and resume the program schedule ADAPTIVE INTELLIGENT RECOVERY AIR Allows the thermostat to learn how long your heater or air cond...

Страница 4: ...gether until screen changes Display will appear as shown below Press the UP arrow 5 times until the screen displays the number 13 on the left side of the screen and 1 on the right Press the DOWN arrow to change the number 1 on the right of the screen to a 0 Press the RUN key to return to normal screen Adaptive Intelligent Recovery has now been removed ...

Страница 5: ...en the REPLACE BATT warning begins to flash The warning flashes about two months before the batteries are depleted If the batteries are inserted within one minute the time and day will not have to be reset All other settings are permanently stored in memory and do not require battery power Pull at bottom to remove from wall plate Turn thermostat over remove batteries insert AA alkaline batteries t...