background image

by

Brivis Inverter Icebox

Installation Manual

REFRIGERANT

R410A

Models:
Outdoor Units

  

Indoor Units

DONSC10Z71  

DINIB10Z7

DONSC13Z71  

DINIB13Z7

DONSC15Z71  

DINIB15Z7

 

Содержание DINIB10Z7

Страница 1: ...by Brivis Inverter Icebox Installation Manual REFRIGERANT R410A Models Outdoor Units Indoor Units DONSC10Z71 DINIB10Z7 DONSC13Z71 DINIB13Z7 DONSC15Z71 DINIB15Z7 ...

Страница 2: ...oor condensing unit Prior to positioning the Icebox heater flue location and service clearances shall be considered All rights reserved No part of these documents may be used in any way or form without prior written consent from Brivis Climate Systems Pty Ltd Specifications are subject to change without notice Brivis Climate Systems Pty Ltd 2019 ...

Страница 3: ...Side 7 3 0 COMPONENTS 8 3 1 Icebox Unit 8 3 2 Starting Collars 8 3 3 Flashing Kit 9 3 4 Fixing Screws 9 4 0 ICEBOX INSTALLATION 9 4 1 Location 10 4 2 Area to cut into the wall 10 4 3 Condensate Drain 11 4 4 Electrical Connection 11 4 5 Thermistor Location BX5 Models 11 4 6 Flashing Wiring Installation 12 4 7 Mounting and secure the Heater 16 4 8 Wiring the Icebox to a BX3 BX5 heater 17 5 0 SYSTEM ...

Страница 4: ...tity requirements passes through the ICE cooling coil at all times Ductwork and fittings must be sized to handle the total cooling airflow through the system on either whole home or zoned basis 1 2 MANDATORY INSPECTION PRIOR TO INSTALLATION Immediately report any damage or discrepancies to the Supplier of the appliance This appliance was inspected and tested at the time of manufacture and packagin...

Страница 5: ...ient Installation of Residential Heating Cooling Air Conditioning Plant Equipment AS 4254 Ductwork for air handling systems in buildings AS NZS 5141 Residential Heating and Cooling Systems Local Electricity Authority Local Building Regulations Environment Authorities Building Code of Australia BCA Brivis SuperSizeGuide Brivisize It is recommended the Brivis SuperSizeGuide Brivisize be followed in ...

Страница 6: ...deration shall be made for flue terminal location and clearance requirements refer to heater installation manual Diagram 2 Icebox Service Clearances Model A B C D E Duct ØRA Duct ØSA Flare ØLL Flare ØSL DINIB10Z7 L 772 844 392 670 460 350 350 9 5 15 9 DINIB10Z7 R 670 460 DINIB13Z7 956 881 566 846 417 19 05 DINIB15Z7 1026 955 496 400 400 Power Lead 2 5m Condensate Drain 3 4 BSP A ØSA ØRA Liquid Lin...

Страница 7: ...gram 3 Icebox Supply Return Air Side 2 3 Changing Icebox Supply Return Air Side To change the supply and return air side for the 13kW or 15kW Icebox do the following 1 Remove the three screws supporting the Top Rail and relocate to the opposite side 2 Remove the ten screws supporting the Pop Cover Plate and relocate to the opposite side Diagram 4 Changing Supply Return Air Side DINIB10Z7 L DINIB13...

Страница 8: ...efer to the General Arrangement drawings 3 2 Starting Collars Insert starting collar pop into the hole in pop plate ensuring pop flange is placed over the inner supply air wall of the cabinet Spread the pop flange to fit tight in the cabinet s hole with the notch side of the collar over lapping the other Secure the pops with the rivets supplied Rivets Supplied Pop Flange IMPORTANT HEATER FLUE THIS...

Страница 9: ...screws have been supplied in a bag with this installation manual and are required to secure the heater to the Icebox 4 0 ICEBOX INSTALLATION Diagram 8 Typical Icebox Installation Item Description Quantity 1 Heater Support Bracket 1 2 Flashing Top 1 3 Flashing Left Hand 1 4 Flashing Right Hand 1 Model Flashing Kit Number Width 150mm Width 250mm DINIB10Z7 L B062743 B062744 DINIB10Z7 R B062743 B06274...

Страница 10: ...hed at condenser end only 4 1 Location Choose a location that is suitable for refrigeration piping and condensate drainage Adequate provision shall be made available for service access Where the unit is installed the wall of the building shall be capable of effectively anchoring the heater Never put the Icebox coil unit in the return air part of the duct system this may result in condensation form...

Страница 11: ...city supply shall be 220 to 240 Volt at 50 Hz and from an authorised power supplier Generators should never be used as their output may be incompatible with or prone to damage the unit s electronic components 4 5 Thermistor Location BX5 Models The thermistor will have to be repositioned to the in cabinet thermistor arm Install the thermistor as follows a Orientate the unit onto the fan cabinet end...

Страница 12: ...that it is equally spaced 5 The small return on the top flashing must be beneath the rail on the Icebox Diagram 12 Top flashing installation Diagram 11 Left and Right hand flashing 1 Position the Icebox on hard level base in front of wall penetration and secure supply and return air duct 2 Remove screws from the Icebox as shown three each side 3 Position the left and right hand side flashings as s...

Страница 13: ...stallation 7 Run a bead of silicone on the flashing faces that will mate with the house 8 Push Icebox into position up against the building wall 9 Install condensate drain Note 2 core shielded communication cable shall be installed from the Icebox unit Terminals S1 S2 to the condenser unit The shield of the cable shall be earthed at the condenser end only refer Diagram 15 2 Core Shielded Communica...

Страница 14: ...14 Diagram 15 3 Core shielded communication cable between indoor and outdoor units ...

Страница 15: ...15 Diagram 16 Wiring at the Icebox PCB Note For installation requirements of the outdoor condenser refer to the installation manual supplied with it ...

Страница 16: ...n the bracket to accommodate all heaters and only two are utilised 3 Using suitable screws item 2 field supplied secure bracket to the building wall 4 Remove the six screws from the base of the heater as shown 5 Replace with the six long series screws supplied with the unit 1 2 Diagram 17 Securing heater support bracket Diagram 18 Securing heater to base box Note The Heater Support Bracket can be ...

Страница 17: ...ctronic Thermostat W Rc EARTH For connection refer to installation instruction supplied with B063033 Loom add on relay classic Add On connections A1 A2 at 516 Zone Module B023178 Add On connections A1 A2 at Brivis Programmable Thermostat and CDU for earth For G connection additional relay is required B063033 Note Early model Buffalos may have on board provisions for add on cooling For more informa...

Страница 18: ...to accept the full air capacity of the system at low noise levels Adequate air filtration must be provided If the system uses high level outlets e g ceiling diffusers then the return air inlet should be at a low level 5 1 Filtration A filter must be fitted into the system and should be easily accessible for regular cleaning Please refer to the guidelines for return air filter grilles accompanying ...

Страница 19: ...n the condenser unit please refer to the Brivis ICE Inverter Technical Specifications page Capacities tested in accordance with AS NZS3823 3 Due to our policy of continuous improvement specifications are subject to change without notice ...

Страница 20: ...ll higher from mobile or public phones For further information visit www rinnai com au or email enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel who are fully trained and equipped to give the best service on your Rinnai appliance If your appliance requires service please call our National Help Line Rinnai recommends that this appliance be serviced every 2 years Wit...

Отзывы: