background image

Supplied By www.heating spares.co  Tel. 0161 620 6677

B BOILER CONTROLS

LEGEND

A.

Boiler thermostat knob.

B.

Main burner 'On' neon.

C.

Control panel door.

Repeat the procedure 1 - 5 detailed in 'To light the boiler'.

Frost protection

If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls (if fitted) at a
reduced temperature setting.
For longer periods, the entire system should be drained -
including the domestic water supply.
If the system includes a frost thermostat then, during cold
weather, the boiler should be turned OFF at the time switch (if
fitted) ONLY. The mains supply should be left switched ON, with
the boiler thermostat left in the normal running position.

Boiler Overheat Thermostat

The  boiler is fitted with a safety 'cutout' thermostat:  this
thermostat will shut down the boiler in the event of overheating.
Should this occur turn off the boiler and consult 

a  

CORGI

registered installer .

Loss of system water pressure

(Boilers fitted with sealed system unit)

If the red arrow on the system pressure gauge is set above zero
and the system pressure is seen to fall below this value over a
period of time then a water leak is indicated.  In this event 

a

CORGI

 

registered installer  should be consulted.

DO  NOT  FIRE  THE  BOILER  IF  THE  PRESSURE  HAS
REDUCED  TO  ZERO  FROM  THE  ORIGINAL  SETTING

Escape of gas

Should a gas leak or fault be suspected, contact your gas supplier

without delay.

Do NOT search for gas leaks with a naked flame.

Cleaning

For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth and
finish off with a dry cloth.

Do NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by 

a

CORGI

 

registered installer .

Note.

 

The appliance model is given on the data plate, located on

the front of the boiler base plate, behind the grille assembly.

THIS SYMBOL IS YOUR
ASSURANCE OF QUALITY

These appliances are designed for use with Natural
Gas only. They have been tested and conform with
the provisions of BS. 6332 and BS. 5258.

CERTIFIED PRODUCT
Manufactured under a BS EN ISO
9001:1994 Quality System
accepted by BSI

May  2001

UIN 155 180 A03

The code of practice for the installation,

commissioning & servicing of central heating systems

British Gas Services

 

Limited

 is a member of the Benchmark

initiative and fully supports the aims of the programme.
Benchmark has been introduced to improve the standards of
installation and commissioning of central heating systems in
the UK and to encourage the regular servicing of all central
heating systems to ensure safety and efficiency.

British Gas

 pursues a policy of

continuing improvement in the
design and performance of its
products. The right is therefore
reserved to vary specification without
notice.

British Gas Services Limited.

 Registered in England No. 3141243. Registered Office:

Charter Court 50 Windsor Road, Slough, Berkshire SL1 2HA. British Gas Services Ltd.
has made every effort to ensure that the information contained in this leaflet is accurate.
However, not all the information is within the control of British Gas Services Ltd., and it
may have changed since publication. British Gas Services Ltd. does not accept any
liability for changes which occur after publication. No guarantee takes away any rights
you may have at law. Calls to this number may be monitored to maintain a high level of
service and for training purposes.

Priority Helpline 08459 500 400

This boiler is exclusively manufactured for British Gas by Ideal Boilers Ltd.

Содержание RD2

Страница 1: ...ww heating spares co Tel 0161 620 6677 USERS G U I D E the floor standing boiler Floor standing gas fired fanned flue boiler 40 125 RD2 Householders guide to domestic central heating boilers British Scottish Gas RD2 ...

Страница 2: ...natural gas models is available The ideal replacement boiler Easy to install easy to operate and easy to service The British Gas RD2 really is the ultimate replacement floor standing range you can depend on it Proven reliability Proven cast iron heat exchanger engineered and refined to be the most dependable floor standing boiler ensuring totally calm operation and quiet running whatever the syste...

Страница 3: ...ar Flue Side Top flue mm in mm in mm in 40 50 Up 10 35 60 70 to 3 8 1 3 8 80 100 600 125 23 5 8 55 2 1 4 55 2 1 4 40 50 600 to 60 70 3000 35 35 80 23 5 8 to 1 3 8 1 3 8 118 100 600 to 2000 35 35 23 5 8 to 1 3 8 1 3 8 78 3 4 125 600 to 1000 55 55 23 5 8 to 2 1 4 2 1 4 39 1 4 Remote appliance diagnostic system This appliance is capable of automatically communicating operational data to a central com...

Страница 4: ... Maintenance The appliance should be serviced at least once a year by a CORGI registered installer Note The appliance model is given on the data plate located on the front of the boiler base plate behind the grille assembly THIS SYMBOL IS YOUR ASSURANCE OF QUALITY These appliances are designed for use with Natural Gas only They have been tested and conform with the provisions of BS 6332 and BS 525...

Отзывы: