The code of practice for the installation,

commissioning & servicing of central heating systems

British Gas Services Limited

 is a member of the Benchmark

initiative and fully supports the aims of the programme.

Benchmark has been introduced to improve the standards of

installation and commissioning of central heating systems in

the UK and to encourage the regular servicing of all central

heating systems to ensure safety and efficiency.

THIS SYMBOL IS YOUR
ASSURANCE OF QUALITY

These appliances are designed for use with Natural
Gas only. They have been tested and conform with
the provisions of BS. 6332 and BS. 5258.

CERTIFIED PRODUCT
Manufactured under a BS EN
ISO 9001:1994 Quality System
accepted by BSI.

British Gas

 pursues a policy of

continuing improvement in the design
and performance of its products. The
right is therefore reserved to vary
specification without notice.

British Gas Services Limited.

 Registered in England No. 3141243. Registered Office:

Charter Court 50 Windsor Road, Slough, Berkshire SL1 2HA. British Gas Services Ltd. has
made every effort to ensure that the information contained in this leaflet is accurate.
However, not all the information is within the control of British Gas Services Ltd., and it may
have changed since publication. British Gas Services Ltd. does not accept any liability for
changes which occur after publication. No guarantee takes away any rights you may have
at law. Calls to this number may be monitored to maintain a high level of service and for
training purposes.

Priority Helpline 08459 500 400

This boiler is exclusively manufactured for British Gas by Ideal Boilers Ltd.

Control of water temperature

1.

Adjust the boiler thermostat (B) to give the required
temperature for central heating.

2.

The boiler thermostat automatically switches the main burner
OFF and ON to maintain the selected temperature.

To shut down the boiler

1. For short periods

Set the boiler On/Off knob (B) to OFF.
When heating is again required, turn the knob to the desired
position.

2. For longer periods

Set the boiler On/Off knob (B) to OFF.
Switch OFF the electricity supply.

To relight the boiler

Repeat the procedure 1 - 8, detailed in 'To light the boiler'.

Frost protection

If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls at a reduced
temperature setting.
For longer periods, the entire system should be drained -
including the domestic water supply.  If the system includes a
frost thermostat then, during cold weather,  the boiler should be

turned OFF at the time switch(es) ONLY. The mains supply
should be left switched ON, with the boiler thermostat left in the
normal running position.

Boiler Overheat Thermostat

The boiler is fitted with a safety 'cutout' thermostat. This will
shut down the boiler in the event of overheating. Should this
occur allow the boiler to cool, press the reset button (E) then
relight as detailed in steps 1-8 in 'To light the boiler'.

If the cutout condition still persists turn off the boiler and consult
a CORGI registered installer.

Loss of system water pressure

Boilers fitted with Sealed System Units only

If the red arrow on the unit pressure gauge is set above zero and
the system pressure is seen to fall below this value over a period
of time then a water leak is indicated.  In this event a CORGI
registered installer should be consulted.
DO NOT OPERATE THE BOILER IF THE PRESSURE HAS
REDUCED TO ZERO FROM THE ORIGINAL SETTING.

Escape of gas

Should a gas leak be suspected, contact your local gas supplier
without delay.

Do NOT search for gas leaks with a naked flame.

Cleaning

For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains, wipe with a damp cloth
and finish off with a dry cloth.

Do NOT use abrasive cleaning materials.

Maintenance

The appliance should be serviced at least once a year by a
CORGI registered installer

.

Approximate flow temperatures for the boiler thermostat settings
are:

Knob Setting

Flow Temperature

°C

°F

1

54

130

2

60

140

3

66

150

4

71

160

5

77

170

6

82

180

Содержание RD1

Страница 1: ...U S E R S G U I D E Householders guide to domestic central heating boilers British Scottish Gas RD1 the wall hung boiler Wall hung gas fired fanned flue boiler 30 100 RD1 ...

Страница 2: ...asy to install easy to operate and easy to service The British Gas RD1 really is the ultimate replacement wall mounted range you can depend on it Proven reliability Proven cast iron heat exchanger engineered and refined to be the most dependable wall mounted boiler ensuring totally calm operation and quiet running whatever the system demands Complete range There are 7 models in the range All model...

Страница 3: ... 100 mm 4 In front of the boiler 75 mm 3 Controls door CL 1037 4 Remote appliance diagnostic system This appliance is capable of automatically communicating operational data to a central computer processing system via the house ring main and telephone line known as Remote Appliance Diagnostic System RADS The information is transmitted in the early hours of the morning once every 30 days or immedia...

Страница 4: ...t the boiler On Off knob B to OFF When heating is again required turn the knob to the desired position 2 For longer periods Set the boiler On Off knob B to OFF Switch OFF the electricity supply To relight the boiler Repeat the procedure 1 8 detailed in To light the boiler Frost protection If no frost protection is provided and frost is likely during a short absence from home leave the heating cont...

Отзывы: