CAUTION. 

 

To avoid the possibility of injury during the installation, servicing or cleaning

of this appliance care should be taken when handling edges of sheet steel components

A BOILER CLEARANCES

Table 1

3.

Switch ON the electricity supply to the boiler and check that
all external controls, e.g. programmer, room thermostat etc.,
are ON.

4.

Set the boiler thermostat knob (A) to position 6. After about
25 seconds the boiler will light automatically and the 'Burner
On' neon (B) will illuminate. Set the boiler thermostat to the
desired position.

5.

Close the control panel door.

Note. 

If the boiler fails to light after 5 attempts consult  a  

CORGI

registered installer.

Winter conditions (i.e. central heating and domestic hot water).

The thermostat should  be positioned at setting 5 or 6.

Summer conditions (i.e. domestic hot water only).

 The

thermostat should be positioned at setting 3.

These settings are offered for general guidance only and other
settings may be found preferable, dependent upon the type of
system installed or as recommended by the installer.

Control of water temperature

1.

Set the boiler thermostat knob (A) to give the required
temperature for central heating.

2.

The boiler thermostat automatically switches the main burner
OFF and ON to maintain the selected temperature.

To shut down the boiler

1. For short periods

Turn the boiler thermostat knob (A) to OFF. When heating is
again required, restore the knob to its original setting.

2. For longer periods

a.

Turn the boiler thermostat knob (A) to OFF.

b.

Switch the electricity supply to OFF.

To relight the boiler

Repeat the procedure 1 - 5 detailed in 'To light the boiler'.

Frost protection

If no frost protection is provided and frost is likely during a short
absence from home, leave the heating controls (if fitted) at a
reduced temperature setting.
For longer periods, the entire system should be drained -

Boiler

Flue

Dimension A

Model

Length

Rear Flue

Side/Top flue

mm (in.)

mm (in.)

mm (in.)

440 , 450

Up

10

35

460 , 470

to

(

3/8

)

(1 

3/8

)

480 , 4100

600

4125

(23 

5/8

)

55 (2 

1/4

)

55 (2 

1/4

)

440 , 450

600 to

460 , 470

3000

35

35

480

(23 

5/8

 to

(1 

3/8

)

(1 

3/8

)

118)

4100

600 to 2000

35

35

(23 

5/8

 to

(1 

3/8

)

(1 

3/8

)

78 

3/4

)

4125

600 to

1000

55

55

(23 

5/8

 to

(2 

1/4

)

(2 

1/4

)

39 

1/4

)

Remote appliance diagnostic system

This appliance is capable of automatically communicating
operational data  to a central computer processing system via the
house ring main and telephone line, known as 'Remote Appliance
Diagnostic System' (RADS).
The information is transmitted in the early hours of the morning
once every 30 days, or immediately if the boiler develops a fault.
If an attempt is made to use the telephone during the
transmission, some interference will be heard. In this event
replace the receiver and try again after 30 seconds.

Important Points

a.

If the boiler is installed in a compartment then the compartment
MUST NOT be used for storage purposes.

b.

The ventilation provided for the boiler during installation MUST
NOT be blocked, and a check should be made periodically that
the ventilation areas are free from any obstruction.

c.

If it is known or suspected that a fault exists on the boiler then it
MUST NOT be used until the fault has been corrected by a

CORGI

 

registered installer.

d.

Flammable materials must not be placed in close proximity to
the appliance.  Materials giving off  flammable vapours must not
be stored in the same room as the appliance.

e.

Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.

In cases of repeated or continuous shutdown  

a  

CORGI

 

registered

installer should be called to investigate and rectify the condition
causing this and carry out an operational test after each intervention
on the device.  Only the manufacturer's original parts should be
used for replacement.

Minimum clearances

A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.
The minimum clearances given in Table 1 MUST be complied with,
in order to maintain the safe running of the boiler.

To light the boiler.

Refer to Frame B

1.

Check that the electricity supply to the boiler is OFF.

2.

Open the control panel drop-down door and ensure that the
thermostat knob (A) is in the OFF position.

Содержание 440 RD2

Страница 1: ...U S E R S G U I D E the floor standing boiler Floor standing gas fired fanned flue boiler 440 4125 RD2 Householders guide to domestic central heating boilers British Scottish Gas RD2 ...

Страница 2: ...available The ideal replacement boiler Easy to install easy to operate and easy to service The British Gas RD2 really is the ultimate replacement floor standing range you can depend on it Proven reliability Proven cast iron heat exchanger engineered and refined to be the most dependable floor standing boiler ensuring totally calm operation and quiet running whatever the system demands Complete ran...

Страница 3: ...00 600 4125 23 5 8 55 2 1 4 55 2 1 4 440 450 600 to 460 470 3000 35 35 480 23 5 8 to 1 3 8 1 3 8 118 4100 600 to 2000 35 35 23 5 8 to 1 3 8 1 3 8 78 3 4 4125 600 to 1000 55 55 23 5 8 to 2 1 4 2 1 4 39 1 4 Remote appliance diagnostic system This appliance is capable of automatically communicating operational data to a central computer processing system via the house ring main and telephone line kno...

Страница 4: ...nces are designed for use with Natural Gas only They have been tested and conform with the provisions of BS 6332 and BS 5258 CERTIFIED PRODUCT Manufactured under a BS EN ISO 9001 1994 Quality System accepted by BSI August 2001 UIN 157 657 A01 The code of practice for the installation commissioning servicing of central heating systems British Gas Services Limited is a member of the Benchmark initia...

Отзывы: