Standby Button: 

Turns the appliance ON/OFF 

standby, the default settings are: 

heater set to 82°F/27°C, the 

main flame effect is F1, the Fuel 

bed is L1 (no temperature display).

Changing Flame Effect: 

In the power-on state, press this 

button, the digital screen displays 

the flame position and the flame 

indicator is bright, and the main 

flame position can be adjusted. 

The flame brightness settings are: 

F1, F2, F3, F4, 

Set as follows:

Button

Display

Flame Effect

1st Press

F1

Full

2nd Press

F2

Medium

3rd Press

F3

Low

4th Press

F4

cycle through 

settings

Heating Operations: 

1)

 Press the heater button to turn 

the heating function on and off 

and adjust the temperature 

setting. Heater is divided into 

temperature settings: 62°, 63°, 

64°, 65°, 66°, 67°, 68°, 69°, 70°, 

71°, 72°, 73°, 74°, 75°, 76°, 77°, 

78°, 79°, 80°, 81°, 82°, ON, 62°F. 

(Circular operation control)

2)

 Press and hold the heater 

button for 3 seconds to convert 

the temperature unit from °C to 

°F. The temperature display 

window will flash. After the 

temperature is set, the display 

unit will flash 5 times, then 

automatically save the settings 

and exit the setting state. After 

the display unit is turned on, if 

there is no operation within 10 

seconds, the setting status is 

also exited.

3)

 

Fan delay function:

 After the  

appliance is turned off, the fan will 

continue running for 15 seconds 

then stop.

Open Window Detection function:

 

When the appliance is heating 

and the ambient temperature 

suddenly drops ≥–5°C (9°F) within 

10 minutes, and the environment 

cannot be warmed up within 30 

minutes the appliance will 

automatically display “OP”. The 

heating function will then be 

automatically turned off, and when 

the “OP” is displayed, it can be 

turned off and then restarted by 

turning off and on the appliance to 

clear the fault code.

4)

 This appliance has a non-self-

resetting overheat protection 

device (thermal cut-out) which will 

activate if the air inlets or outlets 

are obstructed. For safety 

reasons the fire will NOT switch 

on again automatically, the 

following procedure must be 

carried out before the fire can be 

operated.

NOTE: The flame-effect will remain operational if 

the cut-out is activated, only the fan heater is 

prevented from working.

Switch OFF the appliance at the 

wall socket or outlet. Leave the 

fire OFF for a period of no less 

than 10 minutes, ensuring all 

obstructions are removed. Switch 

the appliance ON at the wall. 

Ensure the appliance is turned ON 

at the control switches. If the fire 

fails to operate correctly, repeat 

the above procedure. 

Refer to section 13.0 for more information about 

the Safety Cut-Out System.

Fuel Bed Color Options: 

Once powered, press the “Fuel 

Bed” button and the LCD screen 

on the remote will display the fuel 

bed icon. Now, the fuel bed color 

can be adjusted. The different 

settings are: L1, L2, L3, L4; Fuel 

bed light. 

Set as follows: 

Button

Display

Flame Effect

1st Press

L1

Orange

2nd Press

L2

Blue

3rd Press

L3

 Blue

4th Press

L4

Cycle through  

settings

Setting Sleep Timer: 

In the timed display, press the 

“Sleep Timer” button to adjust the 

time, plus one hour for each 

press. (You can’t enter the weekly 

timing selection, you can only set 

the current automatic shutdown 

time. This function is available 

when the weekly timing function is 

turned on. Will not operate). 

Timing range: 1H, 2H, 3H, 4H, 5H, 

6H, 7H, 8H, 9H, OF, 1H (cycle 

adjustment).

Control Down Lighting: 

Turns the down lighting lights on 

and off.

Setting Clock and Timer: 

Use the date button to choose 

from Monday to Sunday or week 

timer mode option. Option mode: 

1-2-3-4-5-6-7-A-oF.

Clock setting:

1)

 At standby state (after the unit 

is plugged in and before pressing 

“main power”), press and hold the 

Setting button on the remote for 

3 seconds, the digital display will 

then flash “00:00”.

2)

 Press   on the remote control 

to set the hour, press the remote 

control   to set the minutes.

3)

 Press “Setting” to enter the 

setting of the week timer. Press  

 to select Sunday to Saturday,  

The date symbol will light up after 

the day is selected. When finished, 

press the 

 button to exit setting.

NOTE: The current clock must be set after the 

initial power-on or power-off, otherwise the clock 

will remain “00:00” status and you won’t be able 

to set the week timer function.

//

 12.0 OPERATING THE APPLIANCE

 

// 

31

// 

32

© 2020 British Fires

Содержание 18.0 NEW FOREST 1200

Страница 1: ...020 British Fires NEW FOREST ELECTRIC 48 63 FIREPLACES INSTALLATION USER INSTRUCTIONS EN 01 42 FR 43 88 CHEMINÉES ÉLECTRIQUES NEW FOREST DE 122 CM ET 160 CM 48 ET 63 GUIDE D INSTALLATION ET MODE D EMPLOI ...

Страница 2: ... ii iii 2020 British Fires WELCOME TO BRITISH FIRES ...

Страница 3: ...ation 13 9 1 Installation Options 14 9 2 Installation False Chimney Breast Construction 15 16 9 3 Installation Overview 17 18 9 4 Installation Floating Suite 19 22 10 0 Forest View Fuel Bed 23 24 10 1 Slate View Fuel Bed 25 26 10 2 Diamond Light Fuel Bed 27 28 11 0 Pairing the Remote Control 29 12 0 Operating the Appliance 30 33 13 0 Safety Cut Out System 34 14 0 Cleaning and Maintenance 34 15 0 T...

Страница 4: ...ed to reduce the risk of fire electric shock and injury to person including the following 1 Read all instructions before using this heater 2 This heater is hot when in use To avoid burns do not let bare skin touch hot surface If provided use handles when moving this heater Keep combustible materials such as furniture paper and clothes at least 3ft 0 9m away from the front heater 3 Extreme caution ...

Страница 5: ...eedback N A With distance control option No Fan assisted heat output N A With adaptive start control No With working time limitation No Auxiliary electricity consumption Type of heat output room temperature control With black bulb sensor No At nominal heat output elmax 0 0 KW Single stage heat output and no room temperature control No At minimum heat output elmin 0 0 KW Two or more manual stages n...

Страница 6: ...e openings DO NOT use the heater to dry clothes DO NOT site use in an outdoor location s It is important that the following clearances are maintained from the appliance to combustible materials These clearances are dependent on the securing location as defined on the following pages The minimum distance to the front of the appliance is three feet There are no clearances for above or to the side of...

Страница 7: ... screws can be found packaged in the top styrofoam casing and the blanking plates and trims can found underneath the base of the Styrofoam 8 0 PREPARING THE APPLIANCE ALTERING THE CORNER BRACKET POSITION ATTENTION Corner brackets can be found in the styrofoam cap Blanking plates and trims are located attached below to the base styrofoam in the packaging carton Reinstalling the corner bracket Once ...

Страница 8: ... hold the fuel bed into position then carefully remove the fuel bed tray from the appliance and place safely to one side A flat blade screw driver can carefully be used to leaver the fuel bed out if extra hep is required We strongly recommend that protective gloves are worn when handling glass 5 Unscrew the top clamps from each side of the side glass 6 Carefully remove the side glass panels from e...

Страница 9: ...hite neutral wires together with another twist on wire connector 16 Check that the appliance is safe then check the electrical connection to the appliance To check the appliance turn the power on to the appliance then turn the standby button on the top right of the appliance ON Once the appliance is turned on there will be an audible beep to confirm that power is going to the appliance If there is...

Страница 10: ... locations on the top right hand corner of the appliance Each can be accessed through one removable plate This appliance should be positioned on a firm level surface and in a clean dust free environment If fitted into an open chimney the chimney must be blocked off to reduce the risk of draught and damp through the fire which may cause the safety cut out system in the fan heater to operate The bas...

Страница 11: ... the remote to check the appliance before going any further in the installation Once confirmed install the cladding onto the false chimney breast IMPORTANT To pair the remote control please refer to section 11 0 Ensure the structure is safely secured to the wall using the appropriate fixings method please see relevant section 9 0 for further information Step 2 Build frame work and inset the fire S...

Страница 12: ... 9 3 INSTALLATION OVERVIEW Stud wall installation Continued Stud Wall Appliance Non combustible Header Header Header New Forest 48 1200mm Open Dimensions Height Width Depth 22 in 46 in 11 in 565 mm 1175 mm 300 mm New Forest 48 1200mm Open Dimensions Height Width Depth 22 in 46 in 11 in 565 mm 1175 mm 300 mm New Forest 63 1600mm Open Dimensions Height Width Depth 22 in 62 in 11 in 565 mm 1575 mm 30...

Страница 13: ...ance lining up all 8x holes on the floating bracket with the 8x holes on the side of the firebox Then mark with a pencil through the hole in the end of the bracket against the wall 9 Remove the appliance off of the wall 10 Drill a 5 16 in hole at least 2 in deep on either side of the appliance 11 Tap the two wall anchors into the pre drilled holes with a hammer until they are flush with the wall 1...

Страница 14: ...nd screws screw up through the bottom surround and into the legs of the surround top section and up through the floating shelf brackets on the appliance the top section 16 Carefully lower the top section of the surround onto the top of the firebox 21 22 2020 British Fires ...

Страница 15: ...ls still visible 1 2 Using the contents from the Husk bag cover the area on the frosted bed that is still exposed making sure the crystals are still visible 3 Place the logs on top of the base layer created by the crystals Forest terrain Husk and slate pieces Position them as shown above The logs can be placed in any order for this look the larger logs are in the center with the remaining logs aro...

Страница 16: ... evenly throughout on top of the bed of crystals Place the logs on top of the base layer created by the crystals and slate pieces Position them as shown in image 3 The logs can be placed in any order we have used the larger ones as centre pieces and placed the remaining logs around them IMPORTANT Place the logs carefully on the fuel bed ensuring you do not make contact with the rear or side glass ...

Страница 17: ... be spread out across the whole base and form a layer covering the whole area 1 Take the larger crystals and place these in position as shown in image 2 left For the best results remove a small amount of the small crystals and place the larger crystal directly on the frosted base 2 Three Diamond Light color settings 27 28 2020 British Fires ...

Страница 18: ...use the and buttons to select the desired temperature The temperature cannot be adjusted while the daily timer control is in use Only the heating function can be switched Temperature Setting range Centigrade 17 C 18 C 19 C 20 C 21 C 22 C 23 C 24 C 25 C 26 C 27 C ON 17 C Cycle Fahrenheit 62 F 63 F 64 F 65 F 66 F 67 F 68 F 69 F 70 F 71 F 72 F 73 F 74 F 75 F 76 F 77 F 78 F 79 F 80 F 81 F 82 F ON 62 F...

Страница 19: ...efore the fire can be operated NOTE The flame effect will remain operational if the cut out is activated only the fan heater is prevented from working Switch OFF the appliance at the wall socket or outlet Leave the fire OFF for a period of no less than 10 minutes ensuring all obstructions are removed Switch the appliance ON at the wall Ensure the appliance is turned ON at the control switches If t...

Страница 20: ...ters to prevent the remote control and the appliance from failing due to the distance exceeding the effective remote control range when working at the weekly timing After the weekly time is turned on the remote controller automatically controls the appliance at the set appointment time 12 0 OPERATING THE APPLIANCE 13 0 SAFETY CUT OUT SYSTEM 14 0 CLEANING AND MAINTENANCE This appliance has a non se...

Страница 21: ...Check that the air inlet outlet is blocked off Check that the window detection sensor has not activated Display panel shows 88 EE OP There is a fault with the heater Check that the temperature is not set onto the lower settings If the room is warm enough the thermostat will stop the fire switching the heat on Check that the air vent are not blocked off There is an electrical fault A service engine...

Страница 22: ...60320 LARGE END TRIM 19 F960268 REMOTE HANDSET ISS SCALE DATE MATL FIN A B C D DATE CHANGE ACTIONED BY DRWN CHKD LOC USED ON 06 07 2020 Peterd EF40 48 Error No reference X X XX XX 10 FIRST ISSUE A 1 2 3 4 5 6 7 7 8 9 10 11 12 13 14 15 16 17 18 1200 RECOMMENDED SPARES 110V 1 F960261 FRONT GLASS PANEL 2 F960309 GLASS RETAINING BRACKET 3 F960307 FUELBED TRAY 4 F960264 FROSTED FUELBED 5 F960262 REAR G...

Страница 23: ...ts resulting from misuse abuse accident neglect incorrect installation improper maintenance or handling or operation with an incorrect power source What British Fires and its dealers and service agents are also not responsible for In no event will British Fires or its Directors Officers or Agents be liable to the purchaser or any third party Whether in contract in tort or on any other basis for an...

Страница 24: ...mensions A 1175 0 mm 46 in B 311 0 mm 12 in C 1200 0 mm 47 in D 565 0 mm 22 in E 424 0 mm 16 in F 300 0 mm 11 in G 55 5 mm 2 in H 67 0 mm 2 in I 83 5 mm 3 in D Front View A C Top View A C Top View D Front View Dimensions A 1575 0 mm 62 in B 311 0 mm 12 in C 1600 0 mm 63 in D 565 0 mm 22 in E 424 0 mm 16 in F 300 0 mm 11 in G 55 5 mm 2 in H 67 0 mm 2 in I 83 5 mm 3 in 18 0 NEW FOREST 1600 DIMENSION...

Страница 25: ... 43 44 2020 British Fires BIENVENUE CHEZ BRITISH FIRES CHEMINÉES ÉLECTRIQUES NEW FOREST DE 122 CM ET 160 CM 48 ET 63 GUIDE D INSTALLATION ET MODE D EMPLOI ...

Страница 26: ...tallation 60 9 2 Installation Construction d un faux coffrage de cheminée 61 62 9 3 Aperçu de l installation 63 64 9 4 Installation Foyer flottant 65 68 10 0 Couche de combustible Forest View 69 70 10 1 Couche de combustible Slate View 71 72 10 2 Couche de combustible Diamond Light 73 74 11 0 Appariement de la télécommande 75 12 0 Fonctionnement de l appareil 76 79 13 0 Système de coupe circuit 80...

Страница 27: ...us brûler ne touchez pas la surface chaude avec votre peau nue Si des poignées sont fournies utilisez les pour déplacer ce chauffage Les matériaux inflammables tels que meubles papier et vêtements doivent être tenus à au moins 0 9 m 3 pi de l avant du foyer 3 Faites preuve d une extrême prudence lorsqu un chauffage est utilisé par ou à proximité d enfants ou de personnes invalides et quand le chau...

Страница 28: ...harge calorifique électronique avec indication de la température ambiante et ou extérieure N A Avec option de commande à distance Non Rendement énergétique assisté par ventilateur N A Avec commande de démarrage adaptative Non Avec limite de temps de fonctionnement Non Consommation électrique auxiliaire Contrôle de type de rendement énergétique température ambiante Avec capteur à ampoule noire Non ...

Страница 29: ... ou introduire des objets de force dans les ouvertures NE PAS utiliser le chauffage pour sécher des vêtements NE PAS positionner utiliser l appareil à l extérieur Les distances suivantes doivent impérativement être maintenues entre l appareil et des matériaux combustibles Ces distances dépendent de l emplacement de fixation tel que défini dans les pages suivantes La distance minimale par rapport à...

Страница 30: ...ÉPOSER LA VITRE AVANT Douze 12 vis de foyer sont fournies dans la partie supérieure de l emballage en polystyrène Les plaques d obturation et les garnitures se trouvent sous la base de l emballage en polystyrène 8 0 PRÉPARATION DE L APPAREIL CHANGER LA POSITION DU SUPPORT D ANGLE ATTENTION Les supports d angle se trouvent dans le couvercle en polystyrène Les plaques d obturation et les garnitures ...

Страница 31: ...combustible en place puis retirez soigneusement la couche de combustible de l appareil et mettez la de côté en sécurité Au besoin un tournevis plat peut être utilisé avec précaution pour aider à sortir la couche de combustible Nous recommandons vivement de porter des gants de protection pour manipuler la vitre 5 Dévissez les attaches supérieures de chaque côté de la vitre latérale 6 Déposez soigne...

Страница 32: ...lancs ensemble avec un autre capuchon de connexion 16 Vérifiez que l appareil est sûr puis vérifiez le branchement électrique à l appareil Pour vérifier l appareil mettez le sous tension puis mettez le bouton de veille en haut à droite de l appareil sur MARCHE ON Une fois l appareil allumé vous entendrez un bip sonore qui confirme que l appareil est bien sous tension Si aucun courant électrique n ...

Страница 33: ...oit de l appareil Chaque emplacement est accessible en retirant la plaque amovible Cet appareil doit être positionné sur une surface nivelée ferme et dans un environnement propre et exempt de saleté Si l appareil est installé dans une cheminée ouverte la cheminée doit être condamnée pour réduire les risques de courants d air et d humidité dans le foyer susceptibles de déclencher le coupe circuit d...

Страница 34: ...e pour contrôler l appareil avant de poursuivre l installation Une fois l installation confirmée posez le revêtement sur le faux coffrage de cheminée IMPORTANT Pour appairer la télécommande reportez vous à la section 11 0 Assurez vous que la structure est fixée au mur de manière sécurisée à l aide des fixations appropriées voir la section 9 0 pour plus d informations Étape 2 Construire le cadre et...

Страница 35: ...dre suite Cadre Appareil Non combustible Linteau Linteau Linteau New Forest 1200 48 Dimensions en position ouverte Hauteur Largeur Profondeur 565 mm 1175 mm 300 mm 22 po 46 po 11 po New Forest 1200 48 Dimensions en position ouverte Hauteur Largeur Profondeur 565 mm 1175 mm 300 mm 22 po 46 po 11 po New Forest 1600 63 Dimensions en position ouverte Hauteur Largeur Profondeur 565 mm 1575 mm 300 mm 22...

Страница 36: ...x côtés de l appareil en alignant les 8 trous sur le support flottant avec les 8 trous sur le côté du foyer Faites ensuite un repère au crayon à travers le trou à l extrémité du support contre le mur 9 Retirez l appareil du mur 10 Percez un trou de 8 mm 5 16 po à une profondeur d au moins 50 mm 2 po de chaque côté de l appareil 11 Enfoncez doucement les deux chevilles murales dans les trous pré pe...

Страница 37: ...es vis de châssis dans le châssis inférieur et dans les montants de la section supérieure du châssis jusqu aux supports flottants sur la partie supérieure de l appareil 16 Abaissez soigneusement la section supérieure du châssis sur le haut du foyer 67 68 2020 British Fires ...

Страница 38: ...e cosses et recouvrez la zone de la couche dépolie qui est toujours exposée en veillant à ce que les cristaux restent visibles 3 Placez les bûches sur le dessus de la couche de base composée des cristaux du terrain Forest des cosses et des morceaux d ardoise Positionnez les comme indiqué ci dessus Les bûches peuvent être placées dans n importe quel ordre nous avons placé ici les plus grosses bûche...

Страница 39: ...nt partout sur le lit de cristaux Placez les bûches sur le dessus de la couche de base composée des cristaux et des morceaux d ardoise Positionnez les comme indiqué sur la Figure 3 Les bûches peuvent être placées dans n importe quel ordre nous avons mis les plus grosses bûches au centre et celles qui restent autour IMPORTANT Disposez soigneusement les bûches sur la couche de combustible en veillan...

Страница 40: ...t être répartis sur la base toute entière et former une couche recouvrant entièrement la zone 1 Prenez les plus grands cristaux et positionnez les comme indiqué sur la Figure 2 à gauche Pour de meilleurs résultats retirez une petite quantité des petits cristaux et placez directement les grands cristaux sur la base dépolie 2 Trois réglages de couleurs pour Diamond Light 73 74 2020 British Fires ...

Страница 41: ... température souhaitée La température ne peut pas être réglée lorsque la commande de programmation journalière est utilisée Seule la fonction de chauffage peut être activée Plage de réglage de température Degrés centigrades 17 C 18 C 19 C 20 C 21 C 22 C 23 C 24 C 25 C 26 C 27 C ON 17 C cycle Degrés Fahrenheit 62 F 63 F 64 F 65 F 66 F 67 F 68 F 69 F 70 F 71 F 72 F 73 F 74 F 75 F 76 F 77 F 78 F 79 F...

Страница 42: ...me si le coupe circuit est activé seul le générateur d air chaud ne fonctionne plus Débranchez l appareil au niveau de la prise murale Laissez le foyer ÉTEINT pendant au moins 10 minutes en veillant à retirer toutes les obstructions Branchez à nouveau l appareil sur la prise Vérifiez que l appareil soit sur MARCHE au niveau de l interrupteur de commande Si le foyer ne fonctionne pas correctement r...

Страница 43: ...re 80 F appuyez à nouveau sur pour afficher ARRÊT 1 02 00 température 80 F Appuyez sur la touche Réglage à nouveau pour afficher MARCHE 2 03 00 température 79 F puis appuyez sur la touche Réglage pour afficher ARRÊT 2 13 00 température 80 F La télécommande sans fil et l appareil doivent rester à une distance de 4 mètres maximum l un de l autre pour éviter toue défaillance de la télécommande et de ...

Страница 44: ...ge Vérifiez que l entrée la sortie d air n est pas obstruée Vérifiez que le capteur de détection de fenêtre ne s est pas activé Le panneau d affichage indique 88 EE OP Le chauffage présente un défaut Vérifiez que la température n a pas été réglée sur une température inférieure Si la pièce est suffisamment chaude le thermostat empêche le foyer de remettre le chauffage Vérifiez que les évents ne son...

Страница 45: ...NDE TAILLE 19 F960268 TÉLÉCOMMANDE ISS SCALE DATE MATL FIN A B C D DATE CHANGE ACTIONED BY DRWN CHKD LOC USED ON 06 07 2020 Peterd EF40 48 Error No reference X X XX XX 10 FIRST ISSUE A 1 2 3 4 5 6 7 7 8 9 10 11 12 13 14 15 16 17 18 1200 PIÈCES DE RECHANGE RECOMMANDÉES 110V 1 F960261 VITRE AVANT 2 F960309 PATTE DE FIXATION DE LA VITRE 3 F960307 PLATEAU DE COUCHE DE COMBUSTIBLE 4 F960264 COUCHE DE C...

Страница 46: ... d un accident d une négligence d une installation incorrecte d un entretien ou d une manipulation inapproprié e ou d une utilisation avec une source d alimentation inadaptée Ce dont British Fires et ses revendeurs ne sont pas non plus responsables En aucun cas British Fires ou ses dirigeants responsables ou agents ne pourront être tenus responsables vis à vis de l acheteur ou de tout autre tiers ...

Страница 47: ...Éclairage LED E F G I H Vue latérale E F G I H Vue latérale Dimensions A 1175 0 mm 46 po B 311 0 mm 12 po C 1200 0 mm 47 po D 565 0 mm 22 po E 424 0 mm 16 po F 300 0 mm 11 po G 55 5 mm 2 po H 67 0 mm 2 po I 83 5 mm 3 po D Vue avant A C Vue du dessus A C Vue du dessus D Vue avant Dimensions A 1575 0 mm 62 po B 311 0 mm 12 po C 1600 0 mm 63 po D 565 0 mm 22 po E 424 0 mm 16 po F 300 0 mm 11 po G 55 ...

Страница 48: ......

Страница 49: ...B Foyer électrique New Forest 1600 63 EF40 63B British Fires Christchurch Dorset BH23 2BT Royaume Uni RBK House Irishtown Athlone Co Westmeath N37 XP52 Irlande This appliance is only suitable for well insulated spaces or occasional use Please note Except where otherwise stated all rights including copyright in the text images and layout of this booklet is owned by British Fires You are not permitt...

Отзывы: