Briteq RICO-V4 Скачать руководство пользователя страница 3

ENGLISH 

 

OPERATION MANUAL 

 

 
BRITEQ

®

 

1/6 

RICO-V4 

 
 
 

OPERATION MANUAL 

 
Thank  you  for  buying  this  Briteq

®

  product.  To  take  full  advantage  of  all  possibilities,  please  read  these 

operating instructions very carefully.  

 

FEATURES 

  Standalone direct voltage chain hoist motor controller. 

  Controls up to 4 motors in standalone operation 

  Several units can be linked in master/slave using the link in/out on the back panel: 

  Easy control for a larger number of chain hoists. 

  Simultaneous hoist control using the UP/DOWN buttons on the master controller. 

  Centralized Emergency stop on the master controller.  

 

“Slave” indicator led. 

  Manual phase inversion switch for each output. 

  Choice of different outputs for maximum flexibility (rental companies!): 

  4x individual CEE16 4pole 16A outputs 

  1x 16PIN multichannel industrial rectangular connector, Harting

®

 compatible 

  2x 19PIN multichannel industrial round connector, Socapex

®

 compatible  

  1x earthed 16A mains outlet: auxiliary output for all kinds of use. 

  Remote control input (XLR) with led indicator to connect the [RICO-REMOTE] (optional, order code: 4650). 

  Phase indicators to easily check if the 3phases are available. 

  32A  4pole  circuit  breaker  protects  ALL  outputs,  including  the  32A  output  to  the  next  unit.  In  case  of 

emergency all 3 phases AND the neutral are disconnected. 

  Two C16 (16A - 1P+N) 2-POLE automatic circuit breakers for control c auxiliary output. 

  Mains input cable (3x 32A, 5wire), equipped with CEE (3P+N+E) 32A inlet plug 

  CEE (3P+N+E) outlet socket (3x 32A, 5wire) for bypass 

  Extremely robust 19"/4U metal housing. 

 

Designed and build in Europe to the highest international safety standards! 

 

BEFORE USE 

Check the contents: 

Check that the carton contains the following items: 

  [RICO-V4] unit 

  User manual 

 

Some important instructions: 

  Before you start using this unit, plea

se check if there’s no transportation damage. Should there be any, do 

not use the device and consult your dealer first.  

 

Important:

  This  device  left  our  factory  in  perfect  condition  and  well  packaged.  It  is  absolutely  necessary 

for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused 
by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects 
or problems caused by disregarding this user manual. 

  Keep  this  booklet  in  a  safe  place  for  future  consultation.  If  you  sell  the  fixture,  be  sure  to  add  this  user 

manual. 

  To protect the environment, please try to recycle the packing material as much as possible. 

 

Содержание RICO-V4

Страница 1: ......

Страница 2: ......

Страница 3: ...cuit breaker protects ALL outputs including the 32A output to the next unit In case of emergency all 3 phases AND the neutral are disconnected Two C16 16A 1P N 2 POLE automatic circuit breakers for co...

Страница 4: ...main operable for disconnection from the mains The power cord should always be in perfect condition switch the unit immediately off when the power cord is squashed or damaged It must be replaced by th...

Страница 5: ...CO REMOTE controller is connected to the REMOTE CONTROL INPUT 18 The UP DOWN controls can only be operated from the remote controller The EMERGENCY STOP controls are still operational on ALL connected...

Страница 6: ...16A mains output that can be used to all kinds of equipment This output is secured by a 2 pole circuit breaker 4 on the front panel 16 LINK OUT this fixed cable can be used to connect the controller...

Страница 7: ...the controls on the RICO REMOTE Remark the EMERGENCY STOP can be used on all units also on the slaves and remote MASTER SLAVE WITH SEVERAL RICO REMOTE CONTROLLERS Master slave connection is identical...

Страница 8: ...expert Attention We strongly recommend internal cleaning to be carried out by qualified personnel SPECIFICATIONS This unit is radio interference suppressed This product meets the requirements of the c...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ......