![Briteq BEAMSPOT1-TRIAC NW Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/briteq/beamspot1-triac-nw/beamspot1-triac-nw_operation-manual_2814367005.webp)
ENGLISH
OPERATION MANUAL
BRITEQ
®
3/5
BEAMSPOT1-TRIAC NW (WW)
DESCRIPTION:
1. MAINS INPUT:
1m power cord with standard CEE 7/7 mains plug.
2. MAINS FUSE:
protects the unit in case of electrical problems, always use the prescribed fuse!
3. MANUAL DIMMER:
used to dim the output manually.
4. FROST FILTERS:
2 filters (10° and 45°) are included to make the very narrow 4° beam wider. Use the
metal ring to fix one of these filters in front of the 4° lens.
5. HANGING BRACKET:
with a knob on both sides to fasten the unit in the desired position. you can use
the hole in the center of the bracket to fix a hook or truss clamp.
6. SAFETY EYE:
used to attach a safety cable when the unit is rigged, see paragraph “overhead rigging”.
OVERHEAD RIGGING
Important:
The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials should
be used, the installed device should be inspected regularly for safety.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed
at least 50cm
from surrounding walls.
The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
Before r
igging make sure that the installation area can hold a minimum point load of 10times the device’s
weight.
Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
Don’t cover any ventilation openings as this may result in overheating.
The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.