3 Operating and Safety Information
3.1 Qualifi ed Personnel
Installation and maintenance of the fi lter system may be carried out only by trained and
authorised personnel.
3.2 Correct Use
Perfect and safe operation of the product is subject to the installation, use and maintenance
described in this Manual.
3.3 Liability Exclusion
Installation must be executed precisely according to the instructions in this Manual.
BRITA shall not be held liable for any damage, including subsequent damage, arising from
the incorrect use of the product.
3.4 Specifi c Safety Information
Only cold water of drinking water quality may be used as intake water for the BRITA
•
water fi lter system. No microbiologically impaired water or water of unknown micro-
biological quality may be used without appropriate sterilisation.
If there are offi cial instructions to boil tap water, BRITA fi ltered water must also be
•
boiled. When the requirement to boil water comes to an end, the fi lter cartridge must
be replaced and the connections cleaned.
It is generally recommended to boil tap water for certain groups of people (e.g. people
•
with weakened immune systems, babies). This also applies to fi ltered water.
If the BRITA fi lter system is not used for several days (2 – 3 days), we recommend
•
that the AquaVend Cool fi lter system be fl ushed with at least 1.2 litres. BRITA recom-
mends that the fi lter system not be decommissioned for a long period. After stagna-
tion periods of over 4 weeks, the fi lter should be fl ushed with at least 12 litres or,
alternatively, replaced. Please also note the maximum usage period of the fi lter car-
tridge of 6 months (Chapter 5).
The fi lter system must not be opened or dismantled during operation. The fi lter
•
cartridge must not be opened.
The fi lter system fi lter head is designed for a service life of 5 years counted from the
•
date of installation. It must be replaced after 5 years.
Production date
•
Hot embossed stamp on fi lter head / imprint on fi lter cartridge, Example: 5142
5
Production year, here: 2005
14
Production week, here: calendar week 14
2
Production day from Monday (1) to Friday (5), here: Tuesday
Note the Instructions on Replacing the Filter Cartridge for product-specifi c safety
•
information.