2
Identify the required
positition of the valve and
prepare the water supply pipes.
Mark and drill holes. Secure
connectors to pipework using
1/2” BSP female connectors.
(not supplied)
3
1
Installation
Secure the shrouds into
place.
Insert the filter washers
and secure the shower
to the wall mount.
REMEMBER
To service
your
product!
Operation
IMPORTANT
Pack Contents
135-165mm
Centres
1.0
5.0
Pressure
BAR
0.2
4.0
2.0 3.0
Pressure
BAR
1.0
5.0
0.2
4.0
2.0
3.0
60°C
65°C
Specifications
Maximum Static Pressure:
10.0 bar
Inlet Water Temperature
15mm
Compression
Inlet Connections
Min:
0.2 bar
Max:
5.0 bar
Working Pressures
The inlet hot water must
be at least 10°C above the
required blend temperature.
Factory pre-set
38°C
Inlet Dimensions
5°C
25°C
Cold Water Supply
Min:
5°C
Max:
25°C
Hot Water Supply
Tools You’ll need
Flat head Screwdriver
Cross head Screwdriver
Hexagonal Keys
Socket Spanner
Pipe Cutter
Pencil
Drill
Spanner
Installation Instructions
& User Guide
Please leave these instructions
with the end user
Product Codes: ZI SHXSMCT (D8)
All products manufactured and supplied by Bristan are safe to use provided that
they are installed, operated and receive regular maintenance in
accordance with these instructions.
This product needs to be installed in accordance with, and meet the
requirements of the Water Supply (Water Fittings) Regulations 1999 and
current by-laws. For full Installation Requirements & Notes (IRN) please
visit
wras.co.uk/directory.
Isolation valves must be fitted to the inlet water supplies to ensure ease of future
maintenance.
Before installing this product the water supply must be thoroughly flushed in
order to remove any swarf, solder etc.
This product must not be modified in any way as this will invalidate the
guarantee.
Full access must be made available for future maintenance/servicing purposes.
Before drilling into walls, check that there are no hidden electrical wires,
cables or water supply pipes. This can be checked with the aid of an
electronic detector.
If power tools are used do not forget to:
- Wear eye protection
- Unplug equipment after use
If in doubt, contact a registered plumber or your Local Water Authority or
the Secretary of the Institute of Plumbing, address as follows:-
The Institute of Plumbing,
64 Station Lane,
Hornchurch,
Essex,
RM12 6NB, Tel: 01708 472791
Prior to Installation
60-65°C Recommended
Hot
On
Off
REMEMBER
hot on the left,
cold on the
right.
Temperature
Stop
x1
x1
x1
x1
x1
x1
x1
x2
x2
x2
x1
x2
x1
x2
Cold