Maintenance

Temperature Adjustment

This valve is pre-set to a maximum  

outlet temperature of 43°C.

It can be adjusted to have a maximum 

temperature between 38°C - 55°C

IMPORTANT:

 To comply with the 

TMV scheme, this valve cannot have a 

maximum outlet temperature of 44°C.  

If set higher, it will no longer comply  

with the TMV scheme.

Please see the TMV manual supplied 

with this valve for more details.

To adjust the temperature, follow  

the steps below: 

1.  Turn on the valve and set to the 

maximum temperature. 

2.  Remove the knob insert from 

the valve. Using a narrow bladed 

screwdriver, insert through the 

retaining screw and locate into the 

groove of the adjusting screw (Fig 1). 

3.  Turn the adjusting screw clockwise 

for a cooler temperature, anti-

clockwise for a hotter temperature. 

4.  Wait for a few minutes after adjusting 

for the temperature to stabilise. Use 

a thermometer to measure the outlet 

temperature. Repeat steps 2 and 3 

until you reach the desired result. 

5.  Replace the knob insert.

Temperature Stop Adjustment

This method locks the position of the 

control knob so that the valve cannot 

reach a higher temperature.

The valve is factory set to the position 

below: 

•  Position the control knob so that the 

stops on the inside of the knob are 

positioned on each side of the lug in 

the sleeve.  

•  Screw in the retaining screw and 

follow the Temperature Adjustment 

steps to calibrate the temperature. 

•  Replace the knob insert. 

To limit temperature movement, set to 

the position below:

•  Position the control knob so that the 

stops on the inside of the knob are to 

the left of the lug in the sleeve.  

•  Screw in the retaining screw and 

follow the Temperature Adjustment 

steps to calibrate the temperature. 

•  Replace the knob insert.

Содержание TS6000ECP

Страница 1: ...nstructions and User Guide Thermostatic Mixing Valve Models Covered TS6000ECP Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave them...

Страница 2: ...to clog up the mechanical areas of the valve This product must not be modified in any way as this will invalidate the guarantee Full access must be made available for future maintenance servicing pur...

Страница 3: ...to the wall 5 Connect the valve to the pipework using filters to prevent debris entering the valve not supplied We recommend using a high tightening torque 45 50Nm on all 22mm compression fittings to...

Страница 4: ...Ring 1 10 O Ring 1 11 O Ring 1 12 O Ring 1 13 O Ring 1 14 O Ring 1 15 O Ring 1 16 Grub Screw 1 17 Bottom Cap 1 18 Adjusting Screw 1 19 Screw 2 20 Head 1 21 Spindle Nut 1 22 Adjustment Housing 1 23 Ret...

Страница 5: ...ot rinsed off straight after use Household bleaches and cleaners contain harsh chemicals and may damage the surface finish Avoid using abrasive cloths scouring pads scrub sponges steel wool or anythin...

Страница 6: ...cooler temperature anti clockwise for a hotter temperature 4 Wait for a few minutes after adjusting for the temperature to stabilise Use a thermometer to measure the outlet temperature Repeat steps 2...

Страница 7: ...Remove the bottom cap and piston assembly together with the thermostat and return spring Note The piston can be dis assembled further but this is not necessary for cleaning servicing 5 Remove O rings...

Страница 8: ...ww bristan com register For any other queries please call our Customer Service on 0330 026 6273 where our expert team of advisors will be able to offer you any help and advice For full guarantee terms...

Отзывы: