![Bristan TG SNK C Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/bristan/tg-snk-c/tg-snk-c_installation-instructions-and-user-manual_2813537008.webp)
08
Symptom
Symptom
Symptom
Symptom
Cause
Cause
Cause
Cause
Remedy
Remedy
Remedy
Remedy
No flow or poor flow
rate.
Partially closed stop or service
valve in water supply pipework to
the tap.
Open stop or service valve.
Head of water is below the
minimum distance required.
Refer to the Specification section
for minimum pressures required.
Possible airlock / blockage in
supply pipework
Remove water supplies from the
fitting and flush the system to
remove any airlocks / debris.
Cartridge / Valve not opening
fully.
Service fitting. Refer to
maintenance section on page 09
Water dripping for a few
seconds after the tap
has been turned off.
This is caused by ‘capillary
action’ and residual water in the
spout being siphoned out. This
should only last for a couple of
seconds.
Constant dripping /
leaking when the tap is
not in use.
Cartridge / Valve not fully
shutting off.
Service fitting and replace
cartridge / valve. Refer to
maintenance section on page 09
Fitting does not turn on.
Water supplies not turned on.
Check that the water supplies to
the fitting are turned on.
Closed stop or service valve.
Open stop or service valve.
Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Operation
Operation
Operation
Operation
Pulling/pushing the lever backwards/forwards from the mixer body will turn on/off and
increase/decrease the flow of water.
Moving the lever either to the left or right when in the backwards position (when the mixer is
viewed from the front) will increase/decrease the water temperature.
The pull out handset incorporates a push button enabling the water flow to be altered from
an inner water stream to a wider outer spray pattern.