4

 

IMPORTANT FACTS - READ BEFORE COMMENCING PUMP INSTALLATION 

4.1

 

Water Storage Capacity 

The hot and cold water storage capacity must be sufficient to meet the flow rates 

required by the pumped equipment and any other water using fittings and 
appliances, which may be operated simultaneously. 
Ensure the pump is primed as described in the priming section before starting, 
damage to the shaft seal will result otherwise. See Section 8 - Commissioning. 

4.2

 

Water Temperature 

The water entering the pump must be controlled as follows: 

The maximum allowable water temperature is 65 °C.

The minimum allowable water temperature is 4 °C.

DO NOT

 fit a pump if the hot water is heated via a method

 

whereby the water temperature cannot be controlled, such as

 

solar or solid fuel you must consult the Bristan Care helpline on

 

0300 026 6273.

4.3

 

Minimum Flow 

For this pump to operate correctly there must be a minimum gravity flow of at 
least 0.8 l/min through all outlets to be pumped. 

4.4

 

Pipework – General 
Secure pipework

: Ensure pipework to and from pump is independently supported 

& clipped to prevent forces being transferred to inlet and outlet branches of 
pump. 

Flux

: Solder joints must be completed and flux residues removed prior to pump 

installation (

flux damage will void any guarantee

). 

Pipework design

: Care should be taken in the design of pipework runs to minimize 

the risk of air locks e.g. use drawn bends rather than 90° bends. 

DO NOT

 introduce solder flux to flexible hoses, pumps or pump

parts manufactured from plastic.

DO NOT

 allow contact with oil or cellulose based paints, paint

thinners or strippers, acid based descalents or aggressive

cleaning agents.

DO NOT

 install a non-return valve, or devices which contain non-

return valves, in the suction (inlet) pipework to the pump. The

pump must be free to vent to the supply tank at all times.

DO NOT

 bend the flexible hoses beyond 30°. They must be

installed as straight as possible.

DO NOT

 connect this pump to the mains water supply.

Содержание ST PUMP 15TN

Страница 1: ...and safety information Read this manual carefully before commencing installation This manual covers the following products Standard 2 0 bar Single Standard 1 5 bar Twin Pt No ST PUMP 20SG Pt No ST PUM...

Страница 2: ...COMMENCING PUMP INSTALLATION 5 5 LOCATION GENERAL 7 6 PUMP CONNECTIONS 12 7 ELECTRICAL INSTALLATION 18 8 COMMISSIONING 22 9 MAINTENANCE 23 10 TECHNICAL SPECIFICATION Single models 24 11 TECHNICAL SPE...

Страница 3: ...ystems Inlet pressures to the pump and ambient temperatures must not exceed the values given in the technical specifications Bristan shower Single pumps are not suitable for boosting a single side of...

Страница 4: ...national electrical regulations The electrical installation must be installed by a qualified person In the interests of electrical safety a 30 mA residual current device R C D not supplied should be...

Страница 5: ...rs or similarly qualified persons in order to avoid a hazard Please read installation details carefully as they are intended to ensure this product provides long trouble free service Failure to instal...

Страница 6: ...ontact Bristan Ltd within 24 hours of receipt Figure 1 Note This image is for reference only Item Description Qty A Pump 1 B ISO hose integral washer 2 1 C Plain hose integral washer 2 1 Your product...

Страница 7: ...be a minimum gravity flow of at least 0 8 l min through all outlets to be pumped 4 4 Pipework General Secure pipework Ensure pipework to and from pump is independently supported clipped to prevent fo...

Страница 8: ...6 4 5 Plumbing Installation Regulations The plumbing installation must comply with the current water and building regulations The plumbing installation must be installed by a qualified person...

Страница 9: ...er tank Figure 4 and Figure 5 is at least 0 5 metres and does not exceed the max inlet head of 10 metres or 13 metres depending on the model See Sections 10 and 11 Technical Specifications Ambient tem...

Страница 10: ...dance on limitations and recommended location consult the following relevant section for hot or cold water installation Location Single Pump Figure 2 Location Twin pump Figure 3 Standard Twin Pump Sys...

Страница 11: ...r flange b The use of a Stuart Side Entry cylinder flange which should have the addition of an inverted loop U bend of 350 mm minimum drop before rising to the pump located as close as possible to the...

Страница 12: ...10 Figure 5 Twin Pump 200mm min Least preferred area 350mm min Max static inlet pressure 13m Min static inlet pressure 0 5m...

Страница 13: ...eed direct from the hot water cylinder or storage tank ensuring an air free connection to the pump We recommend the use of either the side entry flange SE or a top entry flange TE see Figure 6 Expansi...

Страница 14: ...ors will be attacked and will fail All solder joints should be completed and flux residues removed before final connection to push in connections on the flexible hose Do not allow contact with oil or...

Страница 15: ...to the inlet side of pump to satisfy servicing requirements b Standard hoses with no integral isolating valve should be applied to the outlet side of pump c Use correct tool for opening and closing i...

Страница 16: ...se end running nut is fitted with a rubber sealing washer which is held captive within the nut assembly Locate the hose into position and screw the nut fully onto the fitting by hand Finally nip tight...

Страница 17: ...collapse with the pipe manufacturers recommended support sleeve pipe insert c Appropriate plumbing fitting that provides a leak tight connection Ensure the pipe is free from all score marks and defor...

Страница 18: ...install a 90 bend on the inlet or outlet connections of the pump before the flexible hose to accommodate a low level installation Below are some preferred connection options All connections seal on th...

Страница 19: ...flexible hose supplied Fibre washer 15mm elbow 15mm copper pipe G F flexible hose supplied 15mm compression to G M G F x 15mm tap connector 15mm stem elbow 15mm to G M G F flexible hose supplied G F...

Страница 20: ...rk The cord should be safely routed and secured by cable clips Adjacent pipes Adjacent suction and delivery pipes should be fitted with earthing clamps in accordance with current regulations Figure 12...

Страница 21: ...st be permanently connected to the fixed wiring of the mains supply using the factory fitted supply cord via a double pole switched fused spur off the ring main and NOT connected to the boiler or the...

Страница 22: ...nnected to the terminal in the connection unit which is marked with the letter E or by the earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the t...

Страница 23: ...zard 7 4 Supply Cord Extension The pumps are fitted with a supply cord to the following specification All models HO5VV F3 G 0 75 mm 6 Amp rated cable If the supply cord is to be extended a cord of the...

Страница 24: ...be primed filled with water before starting Turn on water supply from the system service valves prime and vent the pump by opening the pump inlet and outlet isolating valves to allow pump to fill and...

Страница 25: ...inutes every four weeks to exercise all working parts Run on cool water See Section 10 Technical Specification for note on water temperature This particularly applies to guest bathrooms used infrequen...

Страница 26: ...erature 40 C Min Max water temperature Min 4 C Max 65 C Flow switch sensitivity 0 8 l min approx Materials Pump body Plastic Impeller Plastic Mechanical seal EPDM PTFE Al Oxide Connections Pump connec...

Страница 27: ...8 bar Maximum ambient air temperature 40 C Min Max water temperature Min 4 C Max 65 C Flow switch sensitivity 0 8 l min approx Materials Pump body Plastic Impeller Plastic Mechanical seal EPDM PTFE Al...

Страница 28: ...aximum pressure that can be applied to the pump under any installation conditions Note A stored water temperature of 60 C is considered sufficient to meet all normal requirements and will minimize dep...

Страница 29: ...ntermittent flow Incorrect or no anti aeration flange fitted Check that the installation complies with installation instructions Incorrect pipe sizes Check for correct pipe sizing see Section 4 4 Pipe...

Страница 30: ...a closed circuit in either the flow switch reed or P C B in the terminal box Contact Bristan Jammed flow switch Remove outlet hoses and check that flow switch sits in lowest position Check float for f...

Страница 31: ......

Страница 32: ...ctive 2011 65 EU WEEE Directive 2012 19 EU IT IS HEREBY CERTIFIED THAT THE STUART ELECTRIC MOTOR DRIVEN PUMP AS SERIAL NUMBER BELOW COMPLIES WITH THE ESSENTIAL REQUIREMENTS OF THE ABOVE E E C DIRECTIV...

Отзывы: