Remove the
temperature and
flow handles.
4
7
3
2
5
Troubleshooting
To reduce the build up of
limescale and to ensure this
shower works to its maximum
performance we recommend
this shower is serviced every
6-12 months depending on the
hardness of your water.
To replace any spare parts for
your shower why not scan the
below QR Code and search
for your product.
Spare Parts
Servicing Intervals
Maintenance - Cartridge Cleaning
1
6
Symptom
Cause
Remedy
No flow or
low flow rate
partially closed isolation valve.
Open isolation valve.
Instantaneous water heater cycles on and off
as flow rate or pressure is too low.
Increase water flow rate or
pressure through system.
Head of water is below the
minimum distance required.
2 meters minimum required.
Hot or cold water being drawn off elsewhere
causing pressure changes or instantaneous
boiler temperature changes.
Do not use other water outlets when using the taps.
Airlock or partial blockage in the supply
pipework.
Flush through pipework to ensure removal of debris and
any airlocks.
Water
dripping
from shower
This is normal for a short time after using the
shower.
This is caused by residual water tension, the build up of
water in the shower.
If water continues to drip,
possibly due to the cartridge
Remove cartridge and clean, refer to 'Maintenance' section
before starting any maintenance.
Shower does
not turn on
Closed isolation valve.
Open isolation valve.
Mains water supply turned off.
Turn on mains water supply.
At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees
on all our products, effective from the date of purchase, to give you peace of mind.
To start your free guarantee simply scan the QR code and register your product.
Alternatively visit www.bristan.com/register.
For any other queries, please call our Customer Service on 0330 026 6273 where our expert team
of advisors will be able to offer you any help and advice.
For full guarantee terms and conditions visit
www.bristan.com/guarantees
.
Using the wall
mount, isolate
both shower
inlets before
carrying out any
maintenance.
4
2
1
Remove the
temperature
handle and
temperature stop.
Reverse the steps to
replace the temperature
stop and handle.
Turn the shower on and set
the temperature to the
maximum setting. Wait for
the temperature to stabilise.
Turn cartridge spindle clockwise
to decrease the temperature.
Turn cartridge spindle
anti-clockwise to increase
the temperature.
Temperature Setting
3
Remove all O-rings and seals,
check for damage and replace
if necessary.
Soak all other components in a
suitable solution until
fully de-scaled.
Rinse with clean water.
Use WRAS approved grease on
all seals before re-fitting.
Reverse the steps to
reinstall the valve,
cartridge and handles.
Check all joints
and connections
for any leaks.
Turn the water
supply to
the shower
back on.
Remove the cartridge
retaining nut and
cartridge.
Undo the screw underneath
the shower body to remove
the cartridge.
4
1
5
6
Riser Installation
2
3
Assemble
both the top
and bottom
brackets.
Attach the slider, hose
retainer, top and bottom
brackets to the riser rail.
Ensuring its straight, use the
assembled riser to mark the
appropriate positions for
the wall brackets.
Remove the brackets from
the riser. Mark and drill the holes
before securing them to the wall.
Re-attach
the riser to
the secured
brackets.
Connect the
hose to the
shower outlet
and handset,
feeding the
hose through
the hose
retainer.
Place the
handset in
the slider.
1
3
2
3
4
5
REMEMBER
To service
your
product!