Bristan QD SHXSMFF C D3 Скачать руководство пользователя страница 2

Remove the  

temperature and  

flow handles.

4

7

3

2

5

Troubleshooting

To reduce the build up of 

limescale and to ensure this 

shower works to its maximum 

performance we recommend 

this shower is serviced every 

6-12 months depending on the 

hardness of your water.

To replace any spare parts for 

your shower why not scan the 

below QR Code and search 

for your product.

Spare Parts

Servicing Intervals

Maintenance - Cartridge Cleaning

1

6

Symptom

Cause

Remedy

No flow or 

low flow rate

partially closed isolation valve.

Open isolation valve.

Instantaneous water heater cycles on and off 

as flow rate or pressure is too low.

Increase water flow rate or 

pressure through system.

Head of water is below the 

minimum distance required.

2 meters minimum required. 

Hot or cold water being drawn off elsewhere 

causing pressure changes or instantaneous 

boiler temperature changes.

Do not use other water outlets when using the taps.

Airlock or partial blockage in the supply 

pipework.

Flush through pipework to ensure removal of debris and 

any airlocks.

Water 

dripping 

from shower

This is normal for a short time after using the 

shower.

This is caused by residual water tension, the build up of 

water in the shower.

If water continues to drip, 

possibly due to the cartridge

Remove cartridge and clean, refer to 'Maintenance' section 

before starting any maintenance.

Shower does 

not turn on

Closed isolation valve.

Open isolation valve.

Mains water supply turned off.

Turn on mains water supply.

At Bristan, we want to make things as easy as possible for our customers. That’s why we offer solid guarantees  

on all our products, effective from the date of purchase, to give you peace of mind. 

To start your free guarantee simply scan the QR code and register your product.  

Alternatively visit www.bristan.com/register. 

For any other queries, please call our Customer Service on 0330 026 6273 where our expert team  

of advisors will be able to offer you any help and advice. 

For full guarantee terms and conditions visit 

www.bristan.com/guarantees

.

Using the wall 

mount, isolate  

both shower 

inlets before 

carrying out any  

maintenance.

4

2

1

Remove the  

temperature   

handle and  

temperature stop.

Reverse the steps to  

replace the temperature 

stop and handle.

Turn the shower on and set 

the temperature to the  

maximum setting. Wait for  

the temperature to stabilise.

Turn cartridge spindle clockwise 

to decrease the temperature. 

Turn cartridge spindle 

anti-clockwise to increase  

the temperature.

Temperature Setting

3

Remove all O-rings and seals, 

check for damage and replace  

if necessary. 

Soak all other components in a 

suitable solution until  

fully de-scaled.  

Rinse with clean water. 

 

Use WRAS approved grease on 

all seals before re-fitting.

Reverse the steps to 

reinstall the valve, 

cartridge and handles.

Check all joints 

and connections 

for any leaks.

Turn the water 

supply to  

the shower 

back on. 

Remove the cartridge 

retaining nut and 

cartridge.

Undo the screw underneath  

the shower body to remove  

the cartridge.

4

1

5

6

Riser Installation

2

3

Assemble 

both the top 

and bottom 

brackets.

Attach the slider, hose 

retainer, top and bottom 

brackets to the riser rail.

Ensuring its straight, use the  

assembled riser to mark the  

appropriate positions for  

the wall brackets.

Remove the brackets from  

the riser. Mark and drill the holes 

before securing them to the wall.

Re-attach 

the riser to 

the secured 

brackets.

Connect the 

hose to the 

shower outlet 

and handset, 

feeding the 

hose through 

the hose 

retainer.

Place the 

handset in  

the slider.

1

3

2

3

4

5

REMEMBER

 

To service 

your 

product!

Отзывы: